Jim Graham
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jim Graham has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Rayaz Ahmed Malik
Department of Medicine, Weill Cornell Medicine-Qatar, Doha, Qatar
3 shared publications - Mitra Tavakoli
Exeter Diabetes Centre of Excellence (EXCEED), Diabetes and Vascular Research Centre, National Institute for Health Research (NIHR), Exeter Clinical Research Facility University of Exeter Medical School Exeter UK
2 shared publications - Mohammad A. Dabbah
The University of Manchester
2 shared publications - Hugh Devlin
University of Bristol
1 shared publication - I. Petropoulos
The University of Manchester
1 shared publication Ioannis N. Petropoulos
Division of Medicine, Weill Cornell Medical College in Qatar
1 shared publication
Latest Publications
- Open Access
The ADEPT Study, A Comparative Study of Dentists’ Ability to Detect Enamel-only Proximal Caries in Bitewing Radiographs With and Without the use of AssistDent ® Artificial Intelligence Software
Introduction: Reversal of enamel-only proximal caries by non-invasive treatments is important in preventive dentistry. However, detecting such caries using bitewing radiography is difficult, and the subtle patterns are often missed by dental practitioners. Aims: To investigate whether the ability of dentists to detect enamel-only proximal caries is enhanced by the use of AssistDent ® Artificial Intelligence (AI) software. Materials and Methods: In the ADEPT ( A ssist D ent E namel-only P roximal caries assessmen T ) study, twenty-three dentists were randomly divided into a control arm, without AI assistance, and an experimental arm in which AI assistance provided on-screen prompts indicating potential enamel-only proximal caries. All participants analysed a set of 24 bitewings in which an expert panel had previously identified 65 enamel-only carious lesions and 241 healthy proximal surfaces. Results: The control group found 44.3% of the caries, whereas the experimental group found 75.8%. The experimental group incorrectly identified caries in 14.6% of the healthy surfaces compared to 3.7% in the control group. The increase in sensitivity of 71% and decrease in specificity of 11% are statistically significant (p® Artificial Intelligence software significantly improves dentists’ ability to detect enamel-only proximal caries and could be considered as a tool to support preventive dentistry in general practice. Key Points: Enamel-only proximal caries are often missed by dentists when examining bitewing radiographs. The use of AssistDent ® Artificial Intelligence software results in a 71% increase in ability to detect enamel-only proximal caries accompanied by a 11% decrease in specificity. Artificial Intelligence software could be considered as a tool to support preventive dentistry in general practice.
Open AccessThe ADEPT Study, A Comparative Study of Dentists’ Ability to Detect Enamel-only Proximal Caries in Bitewing Radiographs With and Without the use of AssistDent ® Artificial Intelligence Software
Introduction: Reversal of enamel-only proximal caries by non-invasive treatments is important in preventive dentistry. However, detecting such caries using bitewing radiography is difficult, and the subtle patterns are often missed by dental practitioners. Aims: To investigate whether the ability of dentists to detect enamel-only proximal caries is enhanced by the use of AssistDent ® Artificial Intelligence (AI) software. Materials and Methods: In the ADEPT ( A ssist D ent E namel-only P roximal caries assessmen T ) study, twenty-three dentists were randomly divided into a control arm, without AI assistance, and an experimental arm in which AI assistance provided on-screen prompts indicating potential enamel-only proximal caries. All participants analysed a set of 24 bitewings in which an expert panel had previously identified 65 enamel-only carious lesions and 241 healthy proximal surfaces. Results: The control group found 44.3% of the caries, whereas the experimental group found 75.8%. The experimental group incorrectly identified caries in 14.6% of the healthy surfaces compared to 3.7% in the control group. The increase in sensitivity of 71% and decrease in specificity of 11% are statistically significant (p® Artificial Intelligence software significantly improves dentists’ ability to detect enamel-only proximal caries and could be considered as a tool to support preventive dentistry in general practice. Key Points: Enamel-only proximal caries are often missed by dentists when examining bitewing radiographs. The use of AssistDent ® Artificial Intelligence software results in a 71% increase in ability to detect enamel-only proximal caries accompanied by a 11% decrease in specificity. Artificial Intelligence software could be considered as a tool to support preventive dentistry in general practice.
- 7 June 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 64 (4) , 786-794
An Automatic Tool for Quantification of Nerve Fibers in Corneal Confocal Microscopy Images
We describe and evaluate an automated software tool for nerve-fiber detection and quantification in corneal confocal microscopy (CCM) images, combining sensitive nerve-fiber detection with morphological descriptors. Method: We have evaluated the tool for quantification of Diabetic Sensorimotor Polyneuropathy (DSPN) using both new and previously published morphological features. The evaluation used 888 images from 176 subjects (84 controls and 92 patients with type 1 diabetes). The patient group was further subdivided into those with (n = 63) and without (n = 29) DSPN. Results: We achieve improved nervefiber detection over previous results (91.7% sensitivity and specificity in identifying nerve-fiber pixels). Automatic quantification of nerve morphology shows a high correlation with previously reported, manually measured, features. Receiver Operating Characteristic (ROC) analysis of both manual and automatic measurement regimes resulted in similar results in distinguishing patients with DSPN from those without: AUC of about 0.77 and 72% sensitivity-specificity at the equal error rate point. Conclusion: Automated quantification of corneal nerves in CCM images provides a sensitive tool for identification of DSPN. Its performance is equivalent to manual quantification, while improving speed and repeatability. Significance: CCM is a novel in vivo imaging modality that has the potential to be a noninvasive and objective image biomarker for peripheral neuropathy. Automatic quantification of nerve morphology is a major step forward in the early diagnosis and assessment of progression, and, in particular, for use in clinical trials to establish therapeutic benefit in diabetic and other peripheral neuropathies.
- 7 June 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 64 (4) , 786-794
An Automatic Tool for Quantification of Nerve Fibers in Corneal Confocal Microscopy Images
We describe and evaluate an automated software tool for nerve-fiber detection and quantification in corneal confocal microscopy (CCM) images, combining sensitive nerve-fiber detection with morphological descriptors. Method: We have evaluated the tool for quantification of Diabetic Sensorimotor Polyneuropathy (DSPN) using both new and previously published morphological features. The evaluation used 888 images from 176 subjects (84 controls and 92 patients with type 1 diabetes). The patient group was further subdivided into those with (n = 63) and without (n = 29) DSPN. Results: We achieve improved nervefiber detection over previous results (91.7% sensitivity and specificity in identifying nerve-fiber pixels). Automatic quantification of nerve morphology shows a high correlation with previously reported, manually measured, features. Receiver Operating Characteristic (ROC) analysis of both manual and automatic measurement regimes resulted in similar results in distinguishing patients with DSPN from those without: AUC of about 0.77 and 72% sensitivity-specificity at the equal error rate point. Conclusion: Automated quantification of corneal nerves in CCM images provides a sensitive tool for identification of DSPN. Its performance is equivalent to manual quantification, while improving speed and repeatability. Significance: CCM is a novel in vivo imaging modality that has the potential to be a noninvasive and objective image biomarker for peripheral neuropathy. Automatic quantification of nerve morphology is a major step forward in the early diagnosis and assessment of progression, and, in particular, for use in clinical trials to establish therapeutic benefit in diabetic and other peripheral neuropathies.
- 1 January 2015
- Published by Edikta s.r.l. in Bone Abstracts
- Vol. 12 (2) , 178-82
Detecting low bone mineral density from dental radiographs: a mini-review
Over a number of years researchers have reported associations between osteoporosis or low bone mineral density and signs that can be detected on dental radiographs, particularly in the width of the inferior mandibular cortex and the texture of the trabecular bone. As patients visit the dentist more regularly than they visit their doctor, there is the possibility that such signs could be used as a means of identifying individuals at risk of developing osteoporosis or suffering from consequent fracture. This paper reviews the historical background behind this research and the current status, including recent developments in automation of measurement using computer image analysis.
- 1 January 2015
- Published by Edikta s.r.l. in Bone Abstracts
- Vol. 12 (2) , 178-82
Detecting low bone mineral density from dental radiographs: a mini-review
Over a number of years researchers have reported associations between osteoporosis or low bone mineral density and signs that can be detected on dental radiographs, particularly in the width of the inferior mandibular cortex and the texture of the trabecular bone. As patients visit the dentist more regularly than they visit their doctor, there is the possibility that such signs could be used as a means of identifying individuals at risk of developing osteoporosis or suffering from consequent fracture. This paper reviews the historical background behind this research and the current status, including recent developments in automation of measurement using computer image analysis.
- 15 June 2011
- Published by Springer Nature
- p. 145-166
Detecting and Analyzing Linear Structures in Biomedical Images: A Case Study Using Corneal Nerve Fibers
- 15 June 2011
- Published by Springer Nature
- p. 145-166
Detecting and Analyzing Linear Structures in Biomedical Images: A Case Study Using Corneal Nerve Fibers
- Open Access
- 1 January 2010
- Published by Springer Nature
- Vol. 13 (Pt 1) , 300-307
Dual-Model Automatic Detection of Nerve-Fibres in Corneal Confocal Microscopy Images
Corneal Confocal Microscopy (CCM) imaging is a non-invasive surrogate of detecting, quantifying and monitoring diabetic peripheral neuropathy. This paper presents an automated method for detecting nerve-fibres from CCM images using a dual-model detection algorithm and compares the performance to well-established texture and feature detection methods. The algorithm comprises two separate models, one for the background and another for the foreground (nerve-fibres), which work interactively. Our evaluation shows significant improvement (p ≈ 0) in both error rate and signal-to-noise ratio of this model over the competitor methods. The automatic method is also evaluated in comparison with manual ground truth analysis in assessing diabetic neuropathy on the basis of nerve-fibre length, and shows a strong correlation (r = 0.92). Both analyses significantly separate diabetic patients from control subjects (p ≈ 0).
- 1 January 2010
- Published by Springer Nature
- Vol. 13 (Pt 1) , 300-307
Open AccessDual-Model Automatic Detection of Nerve-Fibres in Corneal Confocal Microscopy Images
Corneal Confocal Microscopy (CCM) imaging is a non-invasive surrogate of detecting, quantifying and monitoring diabetic peripheral neuropathy. This paper presents an automated method for detecting nerve-fibres from CCM images using a dual-model detection algorithm and compares the performance to well-established texture and feature detection methods. The algorithm comprises two separate models, one for the background and another for the foreground (nerve-fibres), which work interactively. Our evaluation shows significant improvement (p ≈ 0) in both error rate and signal-to-noise ratio of this model over the competitor methods. The automatic method is also evaluated in comparison with manual ground truth analysis in assessing diabetic neuropathy on the basis of nerve-fibre length, and shows a strong correlation (r = 0.92). Both analyses significantly separate diabetic patients from control subjects (p ≈ 0).
- Open Access
- 7 April 2005
- Published by Springer Nature in BMC Ophthalmology
- Vol. 5 (1) , 9
A freely accessible, evidence based, objective system of analysis of posterior capsular opacification ; Evidence for its validity and reliability
Background: The aim of this study was to develop a system of computerised analysis of digital images of posterior capsule opacification (PCO) that is evidence based, objective and freely available. The paper will present evidence for the reliability and validity of the developed system. Methods: The system of PCO analysis was developed considering current published evidence on visual significance of PCO and additional investigative analysis of PCO images. Details of the image processing and analysis steps are discussed and a final system that measures an entropy score weighted toward proximity to central areas is described. In order to assess validity, the systems ability to measure PCO progression is assessed along with the visual significance of its final computerised scores. Reliability of the system is also assessed. Results: The final system runs successfully and is simple to use. Analyses of PCO by the system show an ability to detect early progression of PCO as well as detection of visually significant PCO. Images with no clinical PCO produce very low scores in the analysis. Reliability of the system of analysis is shown to be satisfactory. Conclusion: This paper presents a system of PCO analysis that is evidence based, objective and clinically useful. Substantial evidence is provided for its validity and reliability.
- 7 April 2005
- Published by Springer Nature in BMC Ophthalmology
- Vol. 5 (1) , 9
Open AccessA freely accessible, evidence based, objective system of analysis of posterior capsular opacification ; Evidence for its validity and reliability
Background: The aim of this study was to develop a system of computerised analysis of digital images of posterior capsule opacification (PCO) that is evidence based, objective and freely available. The paper will present evidence for the reliability and validity of the developed system. Methods: The system of PCO analysis was developed considering current published evidence on visual significance of PCO and additional investigative analysis of PCO images. Details of the image processing and analysis steps are discussed and a final system that measures an entropy score weighted toward proximity to central areas is described. In order to assess validity, the systems ability to measure PCO progression is assessed along with the visual significance of its final computerised scores. Reliability of the system is also assessed. Results: The final system runs successfully and is simple to use. Analyses of PCO by the system show an ability to detect early progression of PCO as well as detection of visually significant PCO. Images with no clinical PCO produce very low scores in the analysis. Reliability of the system of analysis is shown to be satisfactory. Conclusion: This paper presents a system of PCO analysis that is evidence based, objective and clinically useful. Substantial evidence is provided for its validity and reliability.