ZDZachary D. Dunn

Zachary D. Dunn

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zachary D. Dunn has a total of 45 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Two-dimensional size exclusion reversed-phase liquid chromatography for quantitative analysis of L1 proteins in complex vaccine matrices

    by Arthur J. Arcinas, Eli J. Larson, Eric P. Buchhalter, Zachary D. Dunn, Heather Wang, Andrew N. Singh, Rodell C. Barrientos, Ophelia Ukaegbu, Malini Mukherjee, Emmanuel Appiah-Amponsah, et al.


  • High-Throughput Experimentation Reveals Scope and Limitations of Selective Phosphine Reductants and Enables One-Pot mAb Reduction/Conjugation

    by Marion H. Emmert, Cuixian Yang, Eugene E. Kwan, Rebecca Chmielowski, Bruce Kilgore, Zachary L. VanAernum, Cecilia Bottecchia, Rodell C. Barrientos, Monica Haley, Kelly Raymond, et al.


  • Two-Dimensional SEC-SEC-UV-MALS-dRI Workflow for Streamlined Analysis and Characterization of Biopharmaceuticals

    by Rodell C. Barrientos, Andrew N. Singh, Ophelia Ukaegbu, Mohamed Hemida, Heather Wang, Imad Haidar Ahmad, Hang Hu, Zachary D. Dunn, Emmanuel Appiah-Amponsah, Erik L. Regalado

    The emergence of complex biological modalities in the biopharmaceutical industry entails a significant expansion of the current analytical toolbox to address the need to deploy meaningful and reliable assays at an unprecedented pace. Size exclusion chromatography (SEC) is an industry standard technique for protein separation and analysis. Some constraints of traditional SEC stem from its restricted ability to resolve complex mixtures and notoriously long run times while also requiring multiple offline separation conditions on different pore size columns to cover a wider molecular size distribution. Two-dimensional liquid chromatography (2D-LC) is becoming an important tool not only to increase peak capacity but also to tune selectivity in a single online method. Herein, an online 2D-LC framework in which both dimensions utilize SEC columns with different pore sizes is introduced with a goal to increase throughput for biomolecule separation and characterization. In addition to improving the separation of closely related species, this online 2D SEC-SEC approach also facilitated the rapid analysis of protein-based mixtures of a wide molecular size range in a single online experimental run bypassing time-consuming deployment of different offline SEC methods. By coupling the second dimension with multiangle light scattering (MALS) and differential refractive index (dRI) detectors, absolute molecular weights of the separated species were obtained without the use of calibration curves. As illustrated in this report for protein mixtures and vaccine processes, this workflow can be used in scenarios where rapid development and deployment of SEC assays are warranted, enabling bioprocess monitoring, purity assessment, and characterization.


  • Pioneering Just-in-Time (JIT) Strategy for Accelerating Raman Method Development and Implementation for Biologic Continuous Manufacturing

    by Hanzhou Feng, Zachary D. Dunn, Roli Kargupta, Jay Desai, Chelsea Phuangthong, Tayi Venkata, Emmanuel Appiah-Amponsah, Bhumit Patel

    Raman spectroscopy is a popular process analytical technology (PAT) tool that has been increasingly used to monitor and control the monoclonal antibody (mAb) manufacturing process. Although it allows the characterization of a variety of quality attributes by developing chemometric models, a large quantity of representative data is required, and hence, the model development process can be time-consuming. In recent years, the pharmaceutical industry has been expediting new drug development in order to achieve faster delivery of life-changing drugs to patients. The shortened development timelines have impacted the Raman application, as less time is allowed for data collection. To address this problem, an innovative Just-in-Time (JIT) strategy is proposed with the goal of reducing the time needed for Raman model development and ensuring its implementation. To demonstrate its capabilities, a proof-of-concept study was performed by applying the JIT strategy to a biologic continuous process for producing monoclonal antibody products. Raman spectroscopy and online two-dimensional liquid chromatography (2D-LC) were integrated as a PAT analyzer system. Raman models of antibody titer and aggregate percentage were calibrated by chemometric modeling in real-time. The models were also updated in real-time using new data collected during process monitoring. Initial Raman models with adequate performance were established using data collected from two lab-scale cell culture batches and subsequently updated using one scale-up batch. The JIT strategy is capable of accelerating Raman method development to monitor and guide the expedited biologics process development.


  • Automated Online-Sampling Multidimensional Liquid Chromatography with Feedback-Control Capability as a Framework for Real-Time Monitoring of mAb Critical Quality Attributes in Multiple Bioreactors

    by Zachary D. Dunn, Patrick Bohman, Alexis Quinteros, Brian Sauerborn, Felix Milman, Misaal Patel, Roli Kargupta, Suyang Wu, Martin Hornshaw, Rodell Barrientos, et al.

    Real-time monitoring of biopharmaceutical reactors is becoming increasingly important as the processes become more complex. During the continuous manufacturing of monoclonal antibodies (mAbs), the desired mAb product is continually created and collected over a 30 day process, where there can be changes in quality over that time. Liquid chromatography (LC) is the workhorse instrumentation capable of measuring mAb concentration as well as quality attributes such as aggregation, charge variants, oxidation, etc. However, traditional offline sampling is too infrequent to fully characterize bioprocesses, and the typical time from sample generation to data analysis and reporting can take weeks. To circumvent these limitations, an automated online sampling multidimensional workflow was developed to enable streamlined measurements of mAb concentration, aggregation, and charge variants. This analytical framework also facilitates automated data export for real-time analysis of up to six bioreactors, including feedback-controlling capability using readily available LC technology. This workflow increases the data points per bioreactor, improving the understanding of each experiment while also reducing the data turnaround time from weeks to hours. Examples of effective real-time analyses of mAb critical quality attributes are illustrated, showing substantial throughput improvements and accurate results while minimizing labor and manual intervention.


  • Open Access

    Rapid two-dimensional Protein-A size exclusion chromatography of monoclonal antibodies for titer and aggregation measurements from harvested cell culture fluid samples

    by Zachary D. Dunn, Jayesh Desai, Gabriel M. Leme, Dwight R. Stoll, Douglas D. Richardson

    The success of monoclonal antibody (mAb) therapeutics have increased pharmaceutical investment in mAb production, which has led to a greater demand of technologies to efficiently characterize these biotherapeutics. The large size and heterogeneity of mAbs require the measurement of multiple critical quality attributes (CQAs) during production. The current workflow to measure CQAs of antibodies involves multiple one-dimensional liquid chromatography methods, including Protein-A (ProA), ion-exchange (IEX), reversed-phase, size exclusion (SEC), hydrophilic interaction, and hydrophobic interaction (HIC). Recent advances in commercial two-dimensional liquid chromatography (2D-LC) affords an opportunity to perform two separations at once to measure multiple CQAs in a single assay. Here, we describe the development of a 2D ProA–SEC method using entirely commercially available instrumentation. Each individual separation and the transfer of material between dimensions were optimized to develop a method that measures titer and aggregation of a target antibody from harvested cell culture fluid in under 5 min. We determined the effects of each parameter of the method on mAb recovery and stability, as well as speed, robustness, resolution, and accuracy of the aggregate amount detected in the second dimension (2D). While there are still sources of error caused by hardware limitations, our rapid ProA-SEC method is an effective screening tool with a significant throughput advantage over previously described methods. Additionally, this work serves as a basis for developing other 2D-LC methods with ProA as the first dimension (1D) separation coupled with different 2D separation, such as ProA-IEX and ProA-HIC.