A simulation study to compare the phase-shift angle radiofrequency ablation mode with bipolar and unipolar modes in creating linear lesions for atrial fibrillation ablation
Authors:
- 25 February 2016
- journal article
- research article
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 32 (3) , 231-238
Abstract
Purpose In pulmonary veins (PVs) isolation (PVI), radiofrequency (RF) energy is often used to create a linear lesion for blocking the accessory conduction pathways around PVs. By using transient finite element analysis, this study compared the effectiveness of phase-shift mode (PsM) ablation with bipolar mode (BiM) and unipolar mode (UiM) in creating a continuous lesion and lesion depth in a 5-mm thick atrial wall. Materials and methods Computer models were developed to study the temperature distributions and lesion dimensions in atrial walls created through PsM, BiM, and UiM. Four phase-shift angles – 45°, 90°, 135°, and 180° – were considered in PsM ablation (hereafter, PsM-45°, PsM-90°, PsM-135°, and PsM-180°, respectively). Results At 60 s/30 V peak value of RF voltage, UiM and PsM-45° did not create an effective lesion, whereas BiM created a lesion of maximum depth and width approximately 1.01 and 1.62 mm, respectively. PsM-135° and PsM-180° not only created transmural lesions in 5-mm thick atrial walls but also created continuous lesions between electrodes spaced 4 mm apart; similarly, PsM-90° created a continuous lesion with a maximum depth and width of nearly 4.09 and 6.12 mm. Conclusions Compared with UiM and BiM, PsM-90°, PsM-135° and PsM-180° created continuous and larger lesions in a single ablation procedure and at 60 s/30 V peak value of RF voltage. Therefore, the proposed PsM ablation method is suitable for PVI and linear isolation at the left atrial roof for treating atrial fibrillation.Keywords
This publication has 28 references indexed in Scilit:
- Review of the mathematical functions used to model the temperature dependence of electrical and thermal conductivities of biological tissue in radiofrequency ablationInternational Journal of Hyperthermia, 2013
- RETRACTED ARTICLE: Bipolar radiofrequency ablation with four electrodes: Ex vivo liver experiments and finite element method analysis. Influence of inter-electrode distance on coagulation size and geometryInternational Journal of Hyperthermia, 2012
- Catheter Ablation for Paroxysmal Atrial Fibrillation: A Randomized Comparison between Multielectrode Catheter and Point-by-Point AblationPacing and Clinical Electrophysiology, 2010
- A Theoretical and Experimental Analysis of Radiofrequency Ablation with a Multielectrode, Phased, Duty-Cycled SystemPacing and Clinical Electrophysiology, 2010
- Characterization of In Vitro and In Vivo Lesions Made by a Novel Multichannel Ablation Generator and a Circumlinear Decapolar Ablation CatheterJournal of Cardiovascular Electrophysiology, 2009
- Modeling for radio-frequency conductive keratoplasty: implications for the maximum temperature reached in the corneaPhysiological Measurement, 2005
- Thermal-Electrical Modeling for Epicardial Atrial Radiofrequency AblationIEEE Transactions on Biomedical Engineering, 2004
- Modeling bipolar phase-shifted multielectrode catheter ablationIEEE Transactions on Biomedical Engineering, 2002
- Guidelines for predicting lesion size at common endocardial locations during radio-frequency ablationIEEE Transactions on Biomedical Engineering, 2001
- Anatomy of the Left Atrium:Journal of Cardiovascular Electrophysiology, 1999