Optimizing the Response From a Passively Controlled Biventricular Assist Device
- 5 May 2010
- journal article
- Published by Wiley in Artificial Organs
- Vol. 34 (5) , 393-401
Abstract
Recent studies into rotary biventricular support have indicated that inadequate left/right flow balancing may lead to vascular congestion and/or ventricular suckdown. The implementation of a passive controller that automatically adjusts left/right flow during total and partial cardiac support would improve physiological interaction. This has encouraged the development of a biventricular assist device (BiVAD) prototype that achieves passive control of the two rotary pumps' hydraulic output by way of a nonrotating double pressure plate configuration, the hub, suspended between the ventricular assist device (VAD) impellers. Fluctuations in either the VAD's inlet or outlet pressure will cause the hub to translate, and in doing so, affect each pump's hydraulic outputs. In order to achieve partial support, the floating assembly needed to respond to pathologic blood pressure signals while being insensitive to residual ventricular function. An incorporated mechanical spring-mass-damper assembly affects the passive response to optimize the dynamic interaction between the prototype and the supported cardiovascular system. It was found that increasing the damping from a medium to a high level was effective in filtering out the higher frequency ventricular pressure signals, reducing a modified amplitude ratio by up to 72%. A spring response was also identified as being inherent in the passive response and was characterized as being highly nonlinear at the extremes of the floating assembly's translation range. The results from this study introduce a new means of BiVAD control as well as the characterization of a fully passive mechanical physiological controller.Keywords
This publication has 19 references indexed in Scilit:
- A Passively Controlled Biventricular Support DeviceArtificial Organs, 2010
- Optimizing the Response From a Passively Controlled Biventricular Assist DeviceArtificial Organs, 2010
- The BiVACOR Rotary Biventricular Assist Device: Concept and In Vitro InvestigationArtificial Organs, 2008
- Acute In Vivo Evaluation of an Implantable Continuous Flow Biventricular Assist SystemASAIO Journal, 2008
- Progress of Rotary Blood PumpsArtificial Organs, 2006
- Physiological Control of Blood Pumps Using Intrinsic Pump Parameters: A Computer Simulation StudyArtificial Organs, 2006
- Computational and Experimental Evaluation of the Fluid Dynamics and Hemocompatibility of the CentriMag Blood PumpArtificial Organs, 2006
- Computational Fluid Dynamics of Gap Flow in a Biocentrifugal Blood PumpArtificial Organs, 2005
- A Complete Mock Circulation Loop for the Evaluation of Left, Right, and Biventricular Assist DevicesArtificial Organs, 2005
- Current Status of the Gyro Centrifugal Blood Pump—Development of the Permanently Implantable Centrifugal Blood Pump as a Biventricular Assist Device (NEDO Project)Artificial Organs, 2004