    Relative contributions from the ventricle and arterial tree to arterial pressure and its amplification: an experimental study

    by Nicholas Gaddum, Jordi Alastruey, Phil Chowienczyk, Marcel C. M. Rutten, Patrick Segers, Tobias Schaeffter

    Arterial pressure is an important diagnostic parameter for cardiovascular disease. However, relative contributions of individual ventricular and arterial parameters in generating and augmenting pressure are not understood. Using a novel experimental arterial model, our aim was to characterize individual parameter contributions to arterial pressure and its amplification. A piston-driven ventricle provided programmable stroke profiles into various silicone arterial trees and a bovine aorta. Inotropy was varied in the ventricle, and arterial parameters modulated included wall thickness, taper and diameter, the presence of bifurcation, and a native aorta (bovine) versus silicone. Wave reflection at bifurcations was measured and compared with theory, varying parent-to-child tube diameter ratios, and branch angles. Intravascular pressure-tip wires and ultrasonic flow probes measured pressure and flow. Increasing ventricular inotropy independently augmented pressure amplification from 17% to 61% between the lower and higher systolic gradient stroke profiles in the silicone arterial network and from 10% to 32% in the bovine aorta. Amplification increased with presence of a bifurcation, decreasing wall thickness and vessel taper. Pulse pressure increased with increasing wall thickness (stiffness) and taper angle and decreasing diameter. Theoretical predictions of wave transmission through bifurcations werre similar to measurements (correlation: 0.91, R2 = 0.94) but underestimated wave reflection (correlation: 0.75, R2 = 0.94), indicating energy losses during mechanical wave reflection. This study offers the first comprehensive investigation of contributors to hypertensive pressure and its propagation throughout the arterial tree. Importantly, ventricular inotropy plays a crucial role in the amplification of peripheral pressure wave, which offers opportunity for noninvasive assessment of ventricular health. NEW & NOTEWORTHY The present study distinguishes contributions from cardiac and arterial parameters to elevated blood pressure and pressure amplification. Most importantly, it offers the first evidence that ventricular inotropy, an indicator of ventricular function, is an independent determinant of pressure amplification and could be measured with such established devices such as the SphygmoCor.


  • Starling-Like Flow Control of a Left Ventricular Assist Device: In Vitro Validation

    by Nicholas R. Gaddum, Michael Stevens, Einly Lim, John Fraser, Nigel Lovell, David Mason, Daniel Timms, Robert Salamonsen

    The application of rotary left ventricular (LV) assist devices (LVADs) is expanding from bridge to transplant, to destination and bridge to recovery therapy. Conventional constant speed LVAD controllers do not regulate flow according to preload, and can cause over/underpumping, leading to harmful ventricular suction or pulmonary edema, respectively. We implemented a novel adaptive controller which maintains a linear relationship between mean flow and flow pulsatility to imitate native Starling-like flow regulation which requires only the measurement of VAD flow. In vitro controller evaluation was conducted and the flow sensitivity was compared during simulations of postural change, pulmonary hypertension, and the transition from sleep to wake. The Starling-like controller's flow sensitivity to preload was measured as 0.39 L/min/mm Hg, 10 times greater than constant speed control (0.04 L/min/mm Hg). Constant speed control induced LV suction after sudden simulated pulmonary hypertension, whereas Starling-like control reduced mean flow from 4.14 to 3.58 L/min, maintaining safe support. From simulated sleep to wake, Starling-like control increased flow 2.93 to 4.11 L/min as a response to the increased residual LV pulsatility. The proposed controller has the potential to better match device outflow to patient demand in comparison with conventional constant speed control.


  • Beat-to-beat variation in pulse wave velocity during breathing maneuvers

    by Nicholas R. Gaddum, Tobias Schaeffter, Martin Bührer, Marcel Rutten, Lorna Smith, Philip J. Chowienczyk, Philipp B. J. Beerbaum

    Purpose Thoracic pulse wave velocity (PWV) variation due to modulated trans‐mural pressure (TMP) may indicate mechanical properties of the aorta. Our aim was to measure beat‐to‐beat thoracic PWV and TMP to observe its normal variation during respiratory maneuvers. Methods We validated PWV measurements from a real‐time velocity projection MRI scan in a pulsatile phantom. A volunteer study showed inter‐scan repeatability of steady‐state PWV, and observed PWV variation when performing Mueller and Valsalva maneuvers. Synchronized to the real‐time projection velocity data, TMP was measured using a mouth piece and pressure sensor arrangement monitoring the intra‐thoracic pressure and a single arterial pressure measurement. Results In the phantom, beat‐to‐beat PWV derived from real‐time projection (5.33 ± 0.32 m s−1) agreed well with experimentally derived PWV using ultrasound probes (5.72 ± 0.50 m s−1). The within‐subject PWV variation between scans was 0.28 m s−1. Volunteers' PWVs increased during Mueller maneuver (TMP increase of 14.67 ± 10.69 mmHg) by 32% (P < 0.001), and during Valsalva maneuver (TMP decrease of TMP = 17.01 ± 12.91 mmHg), PWV response were inconsistent with an average increase of 14% (P < 0.05). Conclusion Gating TMP to beat‐to‐beat PWV allows insight into how aortic stiffness varies with strain. However, quantifying nonlinear arterial stiffness requires real‐time arterial pressure measurement. Magn Reson Med 72:202–210, 2014.


  • A Technical Assessment of Pulse Wave Velocity Algorithms Applied to Non-invasive Arterial Waveforms

    by N. R. Gaddum, J. Alastruey, P. Beerbaum, P. Chowienczyk, T. Schaeffter

    Non-invasive assessment of arterial stiffness through pulse wave velocity (PWV) analysis is becoming common clinical practice. However, the effects of measurement noise, temporal resolution and similarity of the two waveforms used for PWV calculation upon accuracy and variability are unknown. We studied these effects upon PWV estimates given by foot-to-foot, least squared difference, and cross-correlation algorithms. We assessed accuracy using numerically generated blood pressure and flow waveforms for which the theoretical PWV was known to compare with the algorithm estimates. We assessed variability using clinical measurements in 28 human subjects. Wave shape similarity was quantified using a cross correlation-coefficient (CCCoefficient), which decreases with increasing distance between waveform measurements sites. Based on our results, we propose the following criteria to identify the most accurate and least variable algorithm given the noise, resolution and CCCoefficient of the measured waveforms. (1) Use foot-to-foot when the noise-to-signal ratio ≤10%, and/or temporal resolution ≥100 Hz. Otherwise (2) use a least squares differencing method applied to the systolic upstroke.


  • Increasing the Transmitted Flow Pulse in a Rotary Left Ventricular Assist Device

    by Nicholas Richard Gaddum, John F. Fraser, Daniel Lee Timms


  • Comparison of Preload‐Sensitive Pressure and Flow Controller Strategies for a Dual Device Biventricular Support System

    by Nicholas Richard Gaddum, Daniel Lee Timms, Michael Stevens, David Mason, Nigel Lovell, John F. Fraser

    The use of rotary left ventricular assist devices (LVADs) has extended to destination and recovery therapy for end‐stage heart failure. Incidence of right ventricular failure while on LVAD support requires a second device be implanted to support the failing right ventricle. Without a commercially available implantable rotary right ventricular assist device, rotary LVADs are cannulated into the right heart and operation modified to provide suitable support for the pulmonary system. While this approach can alleviate the demand for transplant through long‐term biventricular support, it uncovers a new challenge with respect to controller strategies for these dual device support systems. This study compares the preload sensitivity of rotary, dual device biventricular assistance controllers in light of their ability to adjust the flow rate according to physiological demand. A Frank–Starling‐like flow controller which requires both inlet pressure and flow sensors is compared to pressure controllers which maintain atrial or inlet cannula pressures through the use of a single pressure sensor. It was found that cannula selection and the location of a pressure controller's single pressure sensor can be tailored to adjust the preload sensitivity. When located within the atria, this sensitivity is effectively infinite. Moving the sensor to the base of a 450‐mm cannula, however, decreased the sensitivity to 0.22 (L/min)/mm Hg. This indicates the potential for simple and reliable VAD controllers with increased preload sensitivity without the need for complex controllers requiring an array of hemodynamic sensors.


  • Biventricular Assist Devices: A Technical Review

    by Shaun D. Gregory, Daniel Timms, Nicholas Gaddum, David G. Mason, John F. Fraser

    The optimal treatment option for end stage heart failure is transplantation; however, the shortage of donor organs necessitates alternative treatment strategies such as mechanical circulatory assistance. Ventricular assist devices (VADs) are employed to support these cases while awaiting cardiac recovery or transplantation, or in some cases as destination therapy. While left ventricular assist device (LVAD) therapy alone is effective in many instances, up to 50% of LVAD recipients demonstrate clinically significant postoperative right ventricular failure and potentially need a biventricular assist device (BiVAD). In these cases, the BiVAD can effectively support both sides of the failing heart. This article presents a technical review of BiVADs, both clinically applied and under development. The BiVADs which have been used clinically are predominantly first generation, pulsatile, and paracorporeal systems that are bulky and prone to device failure, thrombus formation, and infection. While they have saved many lives, they generally necessitate a large external pneumatic driver which inhibits normal movement and quality of life for many patients. In an attempt to alleviate these issues, several smaller, implantable second and third generation devices that use either immersed mechanical blood bearings or hydrodynamic/magnetic levitation systems to support a rotating impeller are under development or in the early stages of clinical use. Although these rotary devices may offer a longer term, completely implantable option for patients with biventricular failure, their control strategies need to be refined to compete with the inherent volume balancing ability of the first generation devices. The BiVAD systems potentially offer an improved quality of life to patients with total heart failure, and thus a viable alternative to heart transplantation is anticipated with continued development.


  • A Passively Controlled Biventricular Support Device

    by Nicholas Richard Gaddum, Daniel Lee Timms, Mark John Pearcy

    Clinical studies have reported the balancing of pump outputs to be a serious control issue for rotary biventricular support (BiVS) systems. Poor reliability of long-term, blood immersed pressure sensors encouraged the development of a new control strategy to improve their viability. A rotary BiVS device was designed and constructed with a mechanical passive controller to autoregulate pump outputs to emulate the native baroreceptor response. In vitro testing in a dual circuit, hydraulic mock circulation loop showed that the prototype was able to maintain arterial pressures when subjected to sudden induced hemodynamic destabilization. However, inlet suction was observed when sudden simulated hypertension briefly reduced venous return to the cannulated ventricle. The results have encouraged further development of the device as a means to create an inherently stable, fully passive biventricular support device.


  • Optimizing the Response From a Passively Controlled Biventricular Assist Device

    by Nicholas Richard Gaddum, Daniel L. Timms, Mark John Pearcy

    Recent studies into rotary biventricular support have indicated that inadequate left/right flow balancing may lead to vascular congestion and/or ventricular suckdown. The implementation of a passive controller that automatically adjusts left/right flow during total and partial cardiac support would improve physiological interaction. This has encouraged the development of a biventricular assist device (BiVAD) prototype that achieves passive control of the two rotary pumps' hydraulic output by way of a nonrotating double pressure plate configuration, the hub, suspended between the ventricular assist device (VAD) impellers. Fluctuations in either the VAD's inlet or outlet pressure will cause the hub to translate, and in doing so, affect each pump's hydraulic outputs. In order to achieve partial support, the floating assembly needed to respond to pathologic blood pressure signals while being insensitive to residual ventricular function. An incorporated mechanical spring-mass-damper assembly affects the passive response to optimize the dynamic interaction between the prototype and the supported cardiovascular system. It was found that increasing the damping from a medium to a high level was effective in filtering out the higher frequency ventricular pressure signals, reducing a modified amplitude ratio by up to 72%. A spring response was also identified as being inherent in the passive response and was characterized as being highly nonlinear at the extremes of the floating assembly's translation range. The results from this study introduce a new means of BiVAD control as well as the characterization of a fully passive mechanical physiological controller.