Energy spectrum and dose enhancement due to the depth of the Lipiodol position using flattened and unflattened beams
Open Access
- 1 January 2018
- journal article
- research article
- Published by VM Media Group sp. z o.o in Reports of Practical Oncology and Radiotherapy
- Vol. 23 (1) , 50-56
Abstract
Lipiodol was used for stereotactic body radiotherapy combining trans arterial chemoembolization. Lipiodol used for tumour seeking in trans arterial chemoembolization remains in stereotactic body radiation therapy. In our previous study, we reported the dose enhancement effect in Lipiodol with 10× flattening-filter-free (FFF). The objective of our study was to evaluate the dose enhancement and energy spectrum of photons and electrons due to the Lipiodol depth with flattened (FF) and FFF beams. FF and FFF for 6 MV beams from TrueBeam were used in this study. The Lipiodol (3 × 3 × 3 cm3) was located at depths of 1, 3, 5, 10, 20, and 30 cm in water. The dose enhancement factor (DEF) and the energy fluence were obtained by Monte Carlo calculations of the particle and heavy ion transport code system (PHITS). The DEFs at the centre of Lipiodol with the FF beam were 6.8, 7.3, 7.6, 7.2, 6.1, and 5.7% and those with the FFF beam were 20.6, 22.0, 21.9, 20.0, 12.3, and 12.1% at depths of 1, 3, 5, 10, 20, and 30 cm, respectively, where Lipiodol was located in water. Moreover, spectrum results showed that more low-energy photons and electrons were present at shallow depth where Lipiodol was located in water. The variation in the low-energy spectrum due to the depth of the Lipiodol position was more explicit with the FFF beam than that with the FF beam. The current study revealed variations in the DEF and energy spectrum due to the depth of the Lipiodol position with the FF and FFF beams. Although the FF beam could reduce the effect of energy dependence due to the depth of the Lipiodol position, the dose enhancement was overall small. To cause a large dose enhancement, the FFF beam with the distance of the patient surface to Lipiodol within 10 cm should be used.Keywords
Funding Information
- Foundation of Cancer Research in Japan
This publication has 16 references indexed in Scilit:
- Dosimetric impact of Lipiodol in stereotactic body radiation therapy on liver after trans‐arterial chemoembolizationMedical Physics, 2016
- Surface dose variations in 6 and 10 MV flattened and flattening filter‐free (FFF) photon beamsJournal of Applied Clinical Medical Physics, 2016
- Implications on clinical scenario of gold nanoparticle radiosensitization in regards to photon energy, nanoparticle size, concentration and locationPhysics in Medicine & Biology, 2011
- Variations in photon energy spectra of a 6 MV beam and their impact on TLD responseMedical Physics, 2011
- Advances in Image-Guided Radiation TherapyJournal of Clinical Oncology, 2007
- Assessment of residual error in liver position using kV cone-beam computed tomography for liver cancer high-precision radiation therapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- A flattening filter free photon treatment concept evaluation with Monte CarloMedical Physics, 2006
- Study Of Local Three-Dimensional Conformal Radiotherapy Combined With Transcatheter Arterial Chemoembolization for Patients With Stage III Hepatocellular CarcinomaAmerican Journal of Clinical Oncology, 2003
- Monte Carlo simulations of the differential beam hardening effect of a flattening filter on a therapeutic x‐ray beamMedical Physics, 1997
- Calculation of x‐ray spectra for radiosurgical beamsMedical Physics, 1995