Cold Junction Compensation Technique of Thermocouple Thermometer Using Radiation-Hardened-by-Design Voltage Reference for Harsh Radiation Environment
- 14 September 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-7
Abstract
This article introduces a radiation-hardened-by-design (RHBD) cold junction compensation (CJC) circuit to compensate for the voltage variation at the cold junction of a thermocouple used in a nuclear power plant (NPP) to detect the reactor temperature. The key idea of the RHBD circuit is to cancel the error induced by radiation, subtracting two reference voltages. In this design, two conditions should be satisfied to realize the first-order cancellation. First, the two voltages should have similar changes according to temperature and radiation. Therefore, two identical voltage generators are used in the proposed circuit. Second, the two reference voltages might have different values. The proposed circuit was fabricated using general purpose 0.18- $\mu \text{m}$ complementary metal–oxide–semiconductor (CMOS) technology with a shallow trench isolation (STI) process. The RHBD CJC circuit showed a reference voltage of 275 mV at room temperature. The final output voltage variation was 5.2 mV under irradiation up to 2 Mrad, and the temperature coefficient (TC) was 2.9 ppm/°C in a range of 20 °–110 °C without additional trimming and annealing. The proposed circuit showed improvements of 60% and 90% for the radiation effect and temperature variation, respectively, compared with the conventional reference circuit. The active area and power consumption were 0.035 mm2 and 1.716 mW, respectively.Keywords
Funding Information
- Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science and Information and Communication Technology (2020M2A8A1000830, 2017M2A8A4017932)
This publication has 24 references indexed in Scilit:
- Monte Carlo Simulation of Radiation Effects *2017
- Radiation Hardening of Voltage References Using Chopper StabilizationIEEE Transactions on Nuclear Science, 2015
- A Wide Temperature, Radiation Tolerant, CMOS-Compatible Precision Voltage Referencefor Extreme Radiation Environment Instrumentation SystemsIEEE Transactions on Nuclear Science, 2013
- A Radiation Hard Bandgap Reference Circuit in a Standard 0.13 $\mu$m CMOS TechnologyIEEE Transactions on Nuclear Science, 2007
- A method to eliminate the effect of radiation on thermocouple performanceNuclear Engineering and Design, 2007
- Comparison of ionizing radiation effects in 0.18 and 0.25 /spl mu/m CMOS technologies for analog applicationsIEEE Transactions on Nuclear Science, 2003
- A new NMOS layout structure for radiation toleranceIEEE Transactions on Nuclear Science, 2002
- Simultaneous calibration of a large number of thermocouplesIEEE Transactions on Instrumentation and Measurement, 2002
- A CMOS bandgap reference circuit with sub-1-V operationIEEE Journal of Solid-State Circuits, 1999
- An automated thermocouple calibration systemIEEE Transactions on Instrumentation and Measurement, 1992