Effect of implant neck design on primary and secondary implant stability in the posterior maxilla: A prospective randomized controlled study
- 13 September 2019
- journal article
- research article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 30 (12) , 1220-1228
Abstract
Objective: To compare the early changes in implant stability of implants with different neck design during the first 3 months of healing in the posterior maxilla.Materials and methods: Patients were randomized to receive triangular neck implant (test), or round neck implant (control). Resonance frequency analysis (ISQ) measurements were obtained at surgery and at 2, 4, 7, 14, 21, 28, 45, 60, and 90 days following implant placement. Non‐parametric statistic was used for data analysis.Results: Thirty‐two patients were included (17 test and 15 controls). Initial ISQ values of the test implants were high (mean: 68.4, SD = 8.4) and increased over time (mean: 74.4, SD = 6.0). Control implants presented a statistically significant higher initial ISQ value at implant placement (mean: 76.9, SD = 8.7), which was maintained over the healing period (mean: 77.6, SD = 3.6) with no significant changes between time intervals. After 6 weeks of healing, both implants displayed comparable ISQ values with no differences between the groups. All implants exhibited a decrease in stability on days 2 and 21 post‐placement. All roundneck implants used, and 82% of the triangularneck implants showed initial ISQ values above the suggested threshold for immediate loading (>60).Conclusions: Implant neck design plays a role in implant primary stability in the posterior maxilla. Both implants show high primary stability, with significantly higher values for the round neck. However, these differences disappeared after 6 weeks of healing. While primary implant stability is partially governed by implant neck design, the role of this result is negligible for the achievement of secondary stability.Keywords
This publication has 34 references indexed in Scilit:
- Retrospective Multicenter Evaluation of Tapered Implant With a Sandblasted and Acid-Etched Surface at 1 to 4 Years of FunctionImplant Dentistry, 2011
- The role of primary stability for successful immediate loading of dental implants. A literature reviewJournal of Dentistry, 2010
- Histological, histomorphometrical, and radiological evaluation of an experimental implant design with a high insertion torqueClinical Oral Implants Research, 2010
- Initial Torque Stability of a New Bone Condensing Dental Implant. A Cohort Study of 140 Consecutively Placed ImplantsJournal of Oral Implantology, 2009
- Early Loading of Nonsubmerged Titanium Implants with a Chemically Modified Sand‐Blasted and Acid‐Etched Surface: 6‐Month Results of a Prospective Case Series Study in the Posterior Mandible Focusing on Peri‐Implant Crestal Bone Changes and Implant Stability Quotient (ISQ) ValuesClinical Implant Dentistry and Related Research, 2009
- Impact of local and systemic factors on the incidence of late oral implant lossClinical Oral Implants Research, 2008
- Removable Prostheses May Enhance Marginal Bone Loss Around Dental Implants: A Long‐Term Retrospective AnalysisJournal of Periodontology, 2007
- Evaluation of Two Different Resonance Frequency Devices to Detect Implant Stability: A Clinical TrialJournal of Periodontology, 2007
- Resonance Frequency Analysis of One‐ Stage Dental Implant Stability During the Osseointegration PeriodJournal of Periodontology, 2005
- Resonance frequency analysis of implants subjected to immediate or early functional occlusal loadingClinical Oral Implants Research, 2004