Experience and complications associated with use of guide extension catheters in percutaneous coronary intervention
Authors:
- 23 December 2015
- journal article
- case report
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 88 (7) , 1057-1065
Abstract
Objectives: To investigate the utility and safety of the GuideLiner “mother‐and‐child” catheter system during transradial and transfemoral percutaneous coronary intervention (PCI).Background: In patients with complex coronary anatomy, stent delivery can be challenging and result in procedural failure and complications. The GuideLiner is a coaxial guide extension system designed to enable deep vessel engagement and facilitate device delivery. The purpose of this study was to evaluate procedural success and safety in a series of GuideLiner‐facilitated PCI.Methods: Single center retrospective study of PCI utilizing the GuideLiner catheter between February 2010 and October 2014. Patients who underwent PCI without GuideLiner use during the same time period were used as controls for comparison.Results: A total of 363 cases of GuideLiner‐facilitated PCI were identified from 6,088 unique PCI procedures performed during this same time period. Patients in the GuideLiner group were older (mean age 71.5 vs. 67.8, P < 0.001) and had more multivessel disease (72% vs. 63%, P = 0.001) compared with controls. Type C lesions were present in 78% of GuideLiner cases. Procedural success resulting in successful device delivery with the GuideLiner catheter was 80.2%. Stent deformation associated with GuideLiner use occurred in 2.2% (8/363), with the incidence of this complication decreasing over device iterations. Coronary dissection attributed to GuideLiner occurred in 3.3% (12/363) and became less frequent over the study period.Conclusions: In this consecutive series of GuideLiner supported PCI, the guide extension system enabled procedural success in the majority. A decline in device‐associated complications over time may be attributed to operator learning curve, patient selection, and improvement in catheter design.Keywords
This publication has 12 references indexed in Scilit:
- GuideLiner Mother‐and‐Child Guide Catheter Extension: A Simple Adjunctive Tool in PCI for Balloon Uncrossable Chronic Total OcclusionsJournal of Interventional Cardiology, 2013
- Left main coronary artery bidirectional dissection caused by ejection of guideliner catheter from the guiding catheterCatheterization and Cardiovascular Interventions, 2013
- Guideliner® catheter—Friend or foe?Catheterization and Cardiovascular Interventions, 2011
- Transfemoral use of the guideLiner catheter in complex coronary and bypass graft interventionsCatheterization and Cardiovascular Interventions, 2011
- Novel use of the guideLiner catheter to minimize contrast use during PCI in a patient with chronic kidney diseaseCatheterization and Cardiovascular Interventions, 2011
- The Guideliner™ Catheter for Stent Delivery in Difficult Cases: Tips and TricksJournal of Interventional Cardiology, 2011
- The use of a guide catheter extension system as an aid during transradial percutaneous coronary intervention of coronary artery bypass graftsCatheterization and Cardiovascular Interventions, 2011
- Distal stent delivery with guideliner catheter: First in man experienceCatheterization and Cardiovascular Interventions, 2010
- Incidence, retrieval methods, and outcomes of stent loss during percutaneous coronary intervention: A large single‐center experienceCatheterization and Cardiovascular Interventions, 2005
- Coronary morphologic and clinical determinants of procedural outcome with angioplasty for multivessel coronary disease. Implications for patient selection. Multivessel Angioplasty Prognosis Study Group.Circulation, 1990