Abstract
Objectives: Iodinated contrast media (ICM) could be more appropriately dosed on patient lean body weight (LBW) than on total body weight (TBW). Methods: After Ethics Committee approval, trial registration NCT03384979, patients aged ≥ 18 years scheduled for multiphasic abdominal CT were randomised for ICM dose to LBW group (0.63 gI/kg of LBW) or TBW group (0.44 gI/kg of TBW). Abdominal 64-row CT was performed using 120 kVp, 100–200 mAs, rotation time 0.5 s, pitch 1, Iopamidol (370 mgI/mL), and flow rate 3 mL/s. Levene, Mann–Whitney U, and χ2 tests were used. The primary endpoint was liver contrast enhancement (LCE). Results: Of 335 enrolled patients, 17 were screening failures; 44 dropped out after randomisation; 274 patients were analysed (133 LBW group, 141 TBW group). The median age of LBW group (66 years) was slightly lower than that of TBW group (70 years). Although the median ICM-injected volume was comparable between groups, its variability was larger in the former (interquartile range 27 mL versus 21 mL, p = 0.01). The same was for unenhanced liver density (IQR 10 versus 7 HU) (p = 0.02). Median LCE was 40 (35–46) HU in the LBW group and 40 (35–44) HU in the TBW group, without significant difference for median (p = 0.41) and variability (p = 0.23). Suboptimal LCE (< 40 HU) was found in 64/133 (48%) patients in the LBW group and 69/141 (49%) in the TBW group, but no examination needed repeating. Conclusions: The calculation of the ICM volume to be administered for abdominal CT based on the LBW does not imply a more consistent LCE.Keywords
This publication has 42 references indexed in Scilit:
- Body size indices to determine iodine mass with contrast-enhanced multi-detector computed tomography of the upper abdomen: does body surface area outperform total body weight or lean body weight?European Radiology, 2013
- Hepatic contrast medium enhancement at computed tomography and its correlation with various body size measuresActa Radiologica, 2012
- Aortic and hepatic enhancement at multidetector CT: Evaluation of optimal iodine dose determined by lean body weightEuropean Journal of Radiology, 2011
- Abdominal multi-detector row CT: Effectiveness of determining contrast medium dose on basis of body surface areaEuropean Journal of Radiology, 2011
- Cost reduction in abdominal CT by weight-adjusted doseEuropean Journal of Radiology, 2009
- Is bioelectrical impedance accurate for use in large epidemiological studies?Nutrition Journal, 2008
- Multiphasic contrast-enhanced multidetector-row CT of liver: Contrast-enhancement theory and practical scan protocol with a combination of fixed injection duration and patients’ body-weight-tailored dose of contrast materialEuropean Journal of Radiology, 2006
- Lean Body Mass as a Predictor of Drug DosageClinical Pharmacokinetics, 1994
- The Meaning and Measurement of Lean Body MassNutrition Reviews, 1991
- Dynamic Contrast Enhancement of the Upper AbdomenInvestigative Radiology, 1983