Design of an Archimedes spiral antenna for PD tests under repetitive impulsive voltages with fast rise times
Authors:
- 6 March 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 26 (2) , 423-430
Abstract
Partial discharge inception voltage measurements under repetitive impulsive voltages play an essential role in evaluating the reliability of inverter-fed low voltage rotating machines. Using impulsive voltages, partial discharge (PD) signals and the disturbance induced by power electronics switches have often similar energy distribution in the frequency domain. Thus, PD test technologies used with sinusoidal voltages are no longer effective. Under repetitive impulsive voltages, ultra-high frequency detection is recommended to couple high-frequency spectral components from the PD and remove the low-frequency disturbance coming from power electronics. However, to obtain high signal to noise (S/N) ratio, the parameters of the antenna used for PD detection should be designed considering the PD and the disturbance energy distributions in the frequency domain. In this paper, we discuss the design and show the properties of an antenna with Archimedes plane spiral structure intended for PD detection under repetitive impulse voltages. The simulation shows that the antenna has low voltage standing wave ratio (<2) and improved directivity in the frequency range from 0.5 to 2 GHz. Moreover, PD tests performed using repetitive square waves with different rise times demonstrate that the designed antenna can receive PD signals efficiently with high S/N.Keywords
This publication has 15 references indexed in Scilit:
- Characteristics of PD under square wave voltages and their influence on motor insulation enduranceIEEE Transactions on Dielectrics and Electrical Insulation, 2015
- Detection and analysis of partial discharge using ultra high frequency sensor2014
- The influence of repetitive square wave voltage parameters on PD statistical features2013
- Antenna selection and frequency response study for UHF detection of partial discharges2012
- Optimisation of a sensor for onsite detection of partial discharges in power transformers by the UHF methodIEEE Transactions on Dielectrics and Electrical Insulation, 2008
- Digital detection, grouping and classification of partial discharge signals at DC voltageIEEE Transactions on Dielectrics and Electrical Insulation, 2008
- A UHF Technique for Advanced PD Measurements on Inverter-Fed MotorsIEEE Transactions on Power Electronics, 2008
- Detection and suppression of corona discharges during PD-measurement by means of RI-reception2002
- Failure mechanism of the interturn insulation of low voltage electric machines fed by pulse controlled inverters2002