Bond strength of AH Plus and Epiphany sealers on root dentine irradiated with 980 nm diode laser
- 12 August 2008
- journal article
- research article
- Published by Wiley in International Endodontic Journal
- Vol. 41 (9) , 733-740
Abstract
Aim To evaluate the bond strength of AH Plus and Epiphany sealers to human root canal dentine irradiated with a 980 nm diode laser at different power and frequency parameters, using the push‐out test.Methodology Sixty canine roots were sectioned below the cementoenamel junction to provide 4‐mm‐thick dentine discs that had their root canals prepared with a tapered bur and irrigated with sodium hypochlorite, ethylenediaminetetraacetic acid and distilled water. The specimens were assigned to five groups (n = 12): one control (no laser) and four experimental groups that were submitted to 980 nm diode laser irradiation at different power (1.5 and 3.0 W) and frequency (continuous wave and 100 Hz) parameters. Half of specimens in each group had their canals filled with AH Plus sealer and half with Epiphany. The push‐out test was performed and data (MPa) were analysed statistically by anova and Tukey’s test (P < 0.05). The specimens were split longitudinally and examined under SEM to assess the failure modes after sealer displacement.Results The specimens irradiated with the diode laser and filled with AH Plus had significantly higher bond strength values (8.69 ± 2.44) than those irradiated and filled with Epiphany (3.28 ± 1.58) and the nonirradiated controls (3.86 ± 0.60). The specimens filled with Epiphany did not differ significantly to each other or to the control (1.75 ± 0.69). There was a predominance of adhesive failures at Epiphany–dentine interface (77%) and mixed failures at AH Plus–dentine interface (67%).Conclusions The 980 nm diode laser irradiation of root canal dentine increased the bond strength of AH Plus sealer, but did not affect the adhesion of Epiphany sealer.Keywords
This publication has 32 references indexed in Scilit:
- Temperature variation at the external root surface during 980-nm diode laser irradiation in the root canalJournal of Dentistry, 2008
- Innovative wavelengths in endodontic treatmentLasers in Surgery and Medicine, 2006
- A comparative study of physicochemical properties of AH PlusTM and EpiphanyTM root canal sealantsInternational Endodontic Journal, 2006
- Bactericidal effects of diode laser on Streptococcus mutans after irradiation through different thickness of dentinLasers in Surgery and Medicine, 2006
- Effects of Diode Laser Irradiation on Smear Layer Removal from Root Canal Walls and Apical Leakage after ObturationPhotomedicine and Laser Surgery, 2005
- Ex vivo study of the adhesion of an epoxy‐based sealer to human dentine submitted to irradiation with Er : YAG and Nd : YAG lasersInternational Endodontic Journal, 2005
- Short‐term antibacterial activity of root canal sealers towards Enterococcus faecalisInternational Endodontic Journal, 2005
- Comparison of 980- and 1064-nm Wavelengths for Interstitial Laser Thermotherapy of the LiverPhotomedicine and Laser Surgery, 2005
- Removal of Epithelium in Periodontal Pockets following Diode (980 nm) Laser Application in the Animal Model: An in Vitro StudyPhotomedicine and Laser Surgery, 2004
- Bactericidal Effect of a 980-nm Diode Laser in the Root Canal Wall Dentin of Bovine TeethJournal of Clinical Laser Medicine & Surgery, 2004