Motion robust coronary MR angiography using zigzag centric ky–kz trajectory and high-resolution deep learning reconstruction
Authors:
- 25 June 2024
- journal article
- research article
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 37 (6) , 1105-1117
Abstract
Purpose To develop a new MR coronary angiography (MRCA) technique by employing a zigzag fan-shaped centric ky–kz k-space trajectory combined with high-resolution deep learning reconstruction (HR-DLR). Methods All imaging data were acquired from 12 healthy subjects and 2 patients using two clinical 3-T MR imagers, with institutional review board approval. Ten healthy subjects underwent both standard 3D fast gradient echo (sFGE) and centric ky–kz k-space trajectory FGE (cFGE) acquisitions to compare the scan time and image quality. Quantitative measures were also performed for signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) as well as sharpness of the vessel. Furthermore, the feasibility of the proposed cFGE sequence was assessed in two patients. For assessing the feasibility of the centric ky–kz trajectory, the navigator-echo window of a 30-mm threshold was applied in cFGE, whereas sFGE was applied using a standard 5-mm threshold. Image quality of MRCA using cFGE with HR-DLR and sFGE without HR-DLR was scored in a 5-point scale (non-diagnostic = 1, fair = 2, moderate = 3, good = 4, and excellent = 5). Image evaluation of cFGE, applying HR-DLR, was compared with sFGE without HR-DLR. Friedman test, Wilcoxon signed-rank test, or paired t tests were performed for the comparison of related variables. Results The actual MRCA scan time of cFGE with a 30-mm threshold was acquired in less than 5 min, achieving nearly 100% efficiency, showcasing its expeditious and robustness. In contrast, sFGE was acquired with a 5-mm threshold and had an average scan time of approximately 15 min. Overall image quality for MRCA was scored 3.3 for sFGE and 2.7 for cFGE without HR-DLR but increased to 3.6 for cFGE with HR-DLR and (p < 0.05). The clinical result of patients obtained within 5 min showed good quality images in both patients, even with a stent, without artifacts. Quantitative measures of SNR, CNR, and sharpness of vessel presented higher in cFGE with HR-DLR. Conclusion Our findings demonstrate a robust, time-efficient solution for high-quality MRCA, enhancing patient comfort and increasing clinical throughput.Keywords
Funding Information
- NIH (R01HL154092)
- Canon Medical Systems Corporation (35938)
This publication has 38 references indexed in Scilit:
- Non-contrast MRI of micro-vascularity of the feet and toesJapanese Journal of Radiology, 2024
- Exploring the impact of super-resolution deep learning on MR angiography image qualityNeuroradiology, 2023
- Ultrashort echo time time‐spatial labeling inversion pulse magnetic resonance angiography with denoising deep learning reconstruction for the assessment of abdominal visceral arteriesJournal of Magnetic Resonance Imaging, 2020
- Natively fat‐suppressed 5D whole‐heart MRI with a radial free‐running fast‐interrupted steady‐state (FISS) sequence at 1.5T and 3TMagnetic Resonance in Medicine, 2019
- Improving Image Resolution of Whole-Heart Coronary MRA Using Convolutional Neural NetworkJournal of Digital Imaging, 2019
- Motion corrected water/fat whole‐heart coronary MR angiography with 100% respiratory efficiencyMagnetic Resonance in Medicine, 2019
- 5D whole‐heart sparse MRIMagnetic Resonance in Medicine, 2017
- Diagnostic accuracy of magnetic resonance angiography for detection of coronary artery disease: a systematic review and meta-analysisEuropean Radiology, 2015
- Highly efficient respiratory motion compensated free‐breathing coronary mra using golden‐step Cartesian acquisitionJournal of Magnetic Resonance Imaging, 2014
- Detection of coronary artery disease by free-breathing, whole heart coronary magnetic resonance angiography: our initial experienceHeart and Vessels, 2009