Our aim was to evaluate if a recently introduced TOF PET system with digital photon counting technology (Philips Healthcare), potentially providing an improved image quality over analogue systems, can fulfil EANM research Ltd (EARL) accreditation specifications for tumour imaging with FDG-PET/CT. We have performed a phantom study on a digital TOF PET system using a NEMA NU2-2001 image quality phantom with six fillable spheres. Phantom preparation and PET/CT acquisition were performed according to the European Association of Nuclear Medicine (EANM) guidelines. We made list-mode ordered-subsets expectation maximization (OSEM) TOF PET reconstructions, with default settings, three voxel sizes (4 × 4 × 4 mm3, 2 × 2 × 2 mm3 and 1 × 1 × 1 mm3) and with/without point spread function (PSF) modelling. On each PET dataset, mean and maximum activity concentration recovery coefficients (RCmean and RCmax) were calculated for all phantom spheres and compared to EARL accreditation specifications. The RCs of the 4 × 4 × 4 mm3 voxel dataset without PSF modelling proved closest to EARL specifications. Next, we added a Gaussian post-smoothing filter with varying kernel widths of 1–7 mm. EARL specifications were fulfilled when using kernel widths of 2 to 4 mm. TOF PET using digital photon counting technology fulfils EARL accreditation specifications for FDG-PET/CT tumour imaging when using an OSEM reconstruction with 4 × 4 × 4 mm3 voxels, no PSF modelling and including a Gaussian post-smoothing filter of 2 to 4 mm.Keywords
Funding Information
- Philips
This publication has 12 references indexed in Scilit:
- Generating harmonized SUV within the EANM EARL accreditation program: software approach versus EARL-compliant reconstructionAnnals of Nuclear Medicine, 2016
- Recent Advances and Future Progress in PET InstrumentationSeminars in Nuclear Medicine, 2016
- Image Quality and Diagnostic Performance of a Digital PET Prototype in Patients with Oncologic Diseases: Initial Experience and Comparison with Analog PETJournal of Nuclear Medicine, 2015
- Improving the Detection of Small Lesions Using a State-of-the-Art Time-of-Flight PET/CT System and Small-Voxel ReconstructionsJournal of Nuclear Medicine Technology, 2015
- FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0European Journal of Nuclear Medicine and Molecular Imaging, 2014
- Harmonizing SUVs in multicentre trials when using different generation PET systems: prospective validation in non-small cell lung cancer patientsEuropean Journal of Nuclear Medicine and Molecular Imaging, 2013
- Performance evaluation of a prototype Positron Emission Tomography scanner using Digital Photon Counters (DPC)2012
- FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0European Journal of Nuclear Medicine and Molecular Imaging, 2009
- The digital silicon photomultiplier — Principle of operation and intrinsic detector performance2009
- The digital Silicon Photomultiplier — A novel sensor for the detection of scintillation light2009