Mechanical behaviour of tissue mimicking breast phantom materials
- 3 July 2017
- journal article
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 3 (4) , 045010
Abstract
The mechanical properties of soft tissue have long been of interest in biomedical research and applications, and increasingly for breast cancer imaging. In this paper, the mechanical properties of three different materials used to emulate the mechanical behaviour of real breast tissue are measured: agar, gelatine, and silicone, to assess their suitability for use in phantoms in systems assessing tissue mechanics for diagnostics. Two widely recognised measurement procedures are used. Quasi-static uniaxial compression was performed under a strain rate of 0.5 mm min −1 up to 15% strain with preloads of 0.05, 0.1, and 0.2 N, was used to measure the elastic moduli. Dynamic testing over a frequency range of 0.1–50 Hz for agar and 0.1–100 Hz for gelatine and silicone with the same preload was used to measure the storage moduli. Elastic and storage moduli were (5–81 kPa, 17–85 kPa, 5–112 kPa) and (3–128 kPa, 10–109 kPa, 5–73 kPa) for agar, gelatine, and silicone, respectively at the three preloads. All materials can be cast into arbitrary shapes and are suitable for tissue-mimicking phantoms. Silicone was the most consistent across the different preloads and frequencies, and can provide a range of stiffness ratios of adipose to tumour tissue that match experimentally reported values. More specifically, silicone samples for skin, adipose and tumour tissues show nonlinear stress–strain characteristics at 3 preloads characterised using hyperelastic parameters by fitting Neo-Hookean, Mooney Rivlin and Ogden models. Silicone also does not contain water, so environmental influences do not affect its mechanical properties as much as the other materials, and is thus more durable for consistent re-use. Finally, breast shaped mimicking silicone phantoms were fabricated for in vitro trials of a digital image elasto tomography breast cancer screening system assessing changes in mechanical properties.Keywords
This publication has 38 references indexed in Scilit:
- Separate modal analysis for tumor detection with a digital image elasto tomography (DIET) breast cancer screening systemMedical Physics, 2013
- Phantom elasticity reconstruction with Digital Image Elasto-TomographyJournal of the Mechanical Behavior of Biomedical Materials, 2011
- Estimating elasticity in heterogeneous phantoms using Digital Image Elasto-TomographyMedical & Biological Engineering & Computing, 2008
- Mammographic screening before age 50 years in the UK: comparison of the radiation risks with the mortality benefitsBritish Journal of Cancer, 2005
- Polyacrylamide gel containing egg white as new model for irradiation experiments using focused ultrasoundUltrasound in Medicine & Biology, 2004
- Digital Image-Based Elasto-Tomography: Proof of Concept Studies for Surface Based Mechanical Property ReconstructionJSME International Journal Series C, 2004
- High-resolution tensor MR elastography for breast tumour detectionPhysics in Medicine & Biology, 2000
- Development of an example flow test object and comparison of five of these test objects, constructed in various laboratoriesUltrasonics, 1998
- Elastic and Acoustic Properties of Vessel Mimicking Material for Elasticity ImagingUltrasonic Imaging, 1997
- Analysis of clinically occult and mammographically occult breast tumorsAmerican Journal of Roentgenology, 1977