Matthew K. Signal
Matthew K. Signal has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Christopher G. Pretty
Department of Mechanical Engineering, University of Canterbury, New Zealand
3 shared publications - Hina M. Ismail
University of Canterbury, 20 Kirkwood Ave, Upper Riccarton, Christchurch, 8041, New Zealand.
3 shared publications - James Geoffrey Chase
University of Canterbury
3 shared publications - Marcus Haggers
Tiro Medical Limited, Building Dg7, Dovedale Village, Dovedale Avenue, Ilam, Christchurch, 8041, New Zealand
3 shared publications - Cong Zhou
University of Canterbury
2 shared publications - Geoffrey William Rodgers
Department of Mechanical Engineering University of Canterbury Christchurch New Zealand
1 shared publication
Latest Publications
- 1 September 2018
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 56 (9) , 1715-1729
Finite element modelling and validation for breast cancer detection using digital image elasto-tomography
Finite element (FE) models are increasingly used to validate experimental data in breast cancer. This research constructed a biomechanical FE model for breast shaped phantoms used to develop and validate a mechanical vibration based screening system. Such models do not currently exist but would enhance development of this screening technology. Three phantoms were modelled: healthy, with 10 and 20 mm inclusions. The overall goal was to create models with enough accuracy to replace experimental phantoms in providing data to optimize diagnostic algorithms for digital image-based elasto-tomography (DIET) screening technologies. FE model results were validating against experimental DIET phantom data for over 4000 collected points on each model and phantom using cross-correlation coefficients between experimental simulated data and direct comparison. Results showed good to strong correlation ranging from 0.7 to 1.0 in all cases with over 90% having a value over 0.9. Magnitudes for each frame of the dynamic response also matched well, indicating that the material properties and geometry were accurate enough to provide this level of correlation. These results justify the use of FE model generated data for in silico diagnostic algorithm development testing. The overall modelling and validation approach is not overly complex, and thus generalizable to similar problems using mechanical properties of silicone phantoms, and might be extensible to human cases with further work.
- 1 September 2018
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 56 (9) , 1715-1729
Finite element modelling and validation for breast cancer detection using digital image elasto-tomography
Finite element (FE) models are increasingly used to validate experimental data in breast cancer. This research constructed a biomechanical FE model for breast shaped phantoms used to develop and validate a mechanical vibration based screening system. Such models do not currently exist but would enhance development of this screening technology. Three phantoms were modelled: healthy, with 10 and 20 mm inclusions. The overall goal was to create models with enough accuracy to replace experimental phantoms in providing data to optimize diagnostic algorithms for digital image-based elasto-tomography (DIET) screening technologies. FE model results were validating against experimental DIET phantom data for over 4000 collected points on each model and phantom using cross-correlation coefficients between experimental simulated data and direct comparison. Results showed good to strong correlation ranging from 0.7 to 1.0 in all cases with over 90% having a value over 0.9. Magnitudes for each frame of the dynamic response also matched well, indicating that the material properties and geometry were accurate enough to provide this level of correlation. These results justify the use of FE model generated data for in silico diagnostic algorithm development testing. The overall modelling and validation approach is not overly complex, and thus generalizable to similar problems using mechanical properties of silicone phantoms, and might be extensible to human cases with further work.
- 3 July 2017
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 3 (4) , 045010
Mechanical behaviour of tissue mimicking breast phantom materials
The mechanical properties of soft tissue have long been of interest in biomedical research and applications, and increasingly for breast cancer imaging. In this paper, the mechanical properties of three different materials used to emulate the mechanical behaviour of real breast tissue are measured: agar, gelatine, and silicone, to assess their suitability for use in phantoms in systems assessing tissue mechanics for diagnostics. Two widely recognised measurement procedures are used. Quasi-static uniaxial compression was performed under a strain rate of 0.5 mm min −1 up to 15% strain with preloads of 0.05, 0.1, and 0.2 N, was used to measure the elastic moduli. Dynamic testing over a frequency range of 0.1–50 Hz for agar and 0.1–100 Hz for gelatine and silicone with the same preload was used to measure the storage moduli. Elastic and storage moduli were (5–81 kPa, 17–85 kPa, 5–112 kPa) and (3–128 kPa, 10–109 kPa, 5–73 kPa) for agar, gelatine, and silicone, respectively at the three preloads. All materials can be cast into arbitrary shapes and are suitable for tissue-mimicking phantoms. Silicone was the most consistent across the different preloads and frequencies, and can provide a range of stiffness ratios of adipose to tumour tissue that match experimentally reported values. More specifically, silicone samples for skin, adipose and tumour tissues show nonlinear stress–strain characteristics at 3 preloads characterised using hyperelastic parameters by fitting Neo-Hookean, Mooney Rivlin and Ogden models. Silicone also does not contain water, so environmental influences do not affect its mechanical properties as much as the other materials, and is thus more durable for consistent re-use. Finally, breast shaped mimicking silicone phantoms were fabricated for in vitro trials of a digital image elasto tomography breast cancer screening system assessing changes in mechanical properties.
- 3 July 2017
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 3 (4) , 045010
Mechanical behaviour of tissue mimicking breast phantom materials
The mechanical properties of soft tissue have long been of interest in biomedical research and applications, and increasingly for breast cancer imaging. In this paper, the mechanical properties of three different materials used to emulate the mechanical behaviour of real breast tissue are measured: agar, gelatine, and silicone, to assess their suitability for use in phantoms in systems assessing tissue mechanics for diagnostics. Two widely recognised measurement procedures are used. Quasi-static uniaxial compression was performed under a strain rate of 0.5 mm min −1 up to 15% strain with preloads of 0.05, 0.1, and 0.2 N, was used to measure the elastic moduli. Dynamic testing over a frequency range of 0.1–50 Hz for agar and 0.1–100 Hz for gelatine and silicone with the same preload was used to measure the storage moduli. Elastic and storage moduli were (5–81 kPa, 17–85 kPa, 5–112 kPa) and (3–128 kPa, 10–109 kPa, 5–73 kPa) for agar, gelatine, and silicone, respectively at the three preloads. All materials can be cast into arbitrary shapes and are suitable for tissue-mimicking phantoms. Silicone was the most consistent across the different preloads and frequencies, and can provide a range of stiffness ratios of adipose to tumour tissue that match experimentally reported values. More specifically, silicone samples for skin, adipose and tumour tissues show nonlinear stress–strain characteristics at 3 preloads characterised using hyperelastic parameters by fitting Neo-Hookean, Mooney Rivlin and Ogden models. Silicone also does not contain water, so environmental influences do not affect its mechanical properties as much as the other materials, and is thus more durable for consistent re-use. Finally, breast shaped mimicking silicone phantoms were fabricated for in vitro trials of a digital image elasto tomography breast cancer screening system assessing changes in mechanical properties.
- 1 July 2017
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 50 (1) , 2037-2042
Sensitivity Analysis for Stiffness Identification Using a DIET Breast Cancer Screening System
- 1 July 2017
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 50 (1) , 2037-2042
Sensitivity Analysis for Stiffness Identification Using a DIET Breast Cancer Screening System