Electrical velocimetry as a tool for measuring cardiac output in small infants after heart surgery
Authors:
- 30 March 2012
- journal article
- research article
- Published by Springer Nature in Intensive Care Medicine
- Vol. 38 (6) , 1032-1039
Abstract
Purpose Cardiac output (CO), the product of stroke volume (SV) and heart rate, is essential to guarantee organ perfusion, especially in the intensive care setting. As invasive measurement of CO bears the risk of complications there is a need for non-invasive alternatives. We investigated if electrical velocimetry (EV) and transthoracic Doppler (Doppler-TTE) are interchangeable for the non-invasive measurement of SV and able to reflect the post-surgical SV/CO trend. Methods Comparison of SV measurements by EV and Doppler-TTE was performed in 24 newborns after switch operation (n = 240 measurements). Three subgroups of measurements (=periods) were created according to the patients’ status in the course of post-surgical CO recovery. Results Bland–Altman analysis found acceptable bias and limits of agreement for the interchangeability of the two methods. Mean overall SV was 3.7 ml with a mean overall bias of 0.28 ml (=7.6 %). The mean percentage error of 29 % was acceptable according to the method of Critchley and Critchley. Overall precision expressed by the coefficient of variation (CV) was 6.6 % for SVTTE and 4.4 % for SVEV. SVTTE and SVEV medians in the three periods were significantly different and documented the post-surgical CO trend. Conclusions EV and Doppler-TTE are interchangeable for estimating SV. EV has the advantages of easy handling and allows continuous measurement.Keywords
This publication has 27 references indexed in Scilit:
- Evaluation of the Aesculon cardiac output monitor by subxiphoidal Doppler flow measurement in children with congenital heart defectsEuropean Journal of Anaesthesiology, 2009
- Haemodynamic Changes During Craniotomy Monitored By A Bioimpedance Plethysmographic Noninvasive Cardiac Output MonitorJournal of Clinical Monitoring and Computing, 2009
- A Measure of Confidence in Bland–Altman Analysis for the Interchangeability of Two Methods of MeasurementJournal of Clinical Monitoring and Computing, 2008
- Time Course and Prognostic Value of Plasma B-type Natriuretic Peptide Concentration in Neonates Undergoing the Arterial Switch OperationAnesthesia & Analgesia, 2007
- Clinicians' abilities to estimate cardiac index in ventilated children and infantsArchives of Disease in Childhood, 1997
- A study of the human aortic valve orifice by transesophageal echocardiographyJournal of the American Society of Echocardiography, 1996
- Postoperative Course and Hemodynamic Profile After the Arterial Switch Operation in Neonates and InfantsCirculation, 1995
- Cardiac Output by Transesophageal Echocardiography Using Continuous-wave Doppler across the Aortic ValveAnesthesiology, 1994
- Reproducibility of measurements of cardiac output in newborn infants by Doppler ultrasound.Archives of Disease in Childhood, 1990
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986