Oswin Grollmuss
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Oswin Grollmuss has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Ahmed G. Siam
Pediatrics Department, Faculty of Medicine, Zagazig University , Zagazig , Egypt
1 shared publicationAlain Serraf
Department of Pediatric Cardiac Intensive Care, Centre Chirurgical Marie Lannelongue, Le Plessis Robinson, France
1 shared publicationAndré Capderou
Department of Pediatric Cardiac Intensive Care, Centre Chirurgical Marie Lannelongue, INSERM 999, University Paris Sud, Le Plessis Robinson, France
1 shared publicationBasheir A. Hassan
Pediatrics Department, Faculty of Medicine, Zagazig University , Zagazig , Egypt
1 shared publicationEhab A. Albanna
Pediatrics Department, Faculty of Medicine, Zagazig University , Zagazig , Egypt
1 shared publicationEmre Belli
Department of Pediatric Cardiac Intensive Care, Centre Chirurgical Marie Lannelongue, Le Plessis Robinson, France
1 shared publication
Latest Publications
- Open Access
- 15 June 2015
- Published by Frontiers Media SA in Frontiers in Pediatrics
- Vol. 3, 53
Nutritional Status in Children with Un-Operated Congenital Heart Disease: An Egyptian Center Experience
Background: Malnutrition is a common cause of morbidity and mortality in children with congenital heart disease (CHD).This study aimed to identify prevalence and predictors of malnutrition in Egyptian children with symptomatic CHD. Methods: This case-control study included 100 children with symptomatic CHD (76 acyanotic and 24 cyanotic) and 100 age and sex-matched healthy children as a control group. Clinical Evaluation and Laboratory Assessment of Nutritional Status were done. Anthropometric measurements were recorded and Z scores for weight for age (WAZ), weight for height (WHZ) and height for age (HAZ) were calculated. Malnutrition was defined as weight, height and weight/ height z-score ≤ –2. Results: The overall prevalence of malnutrition was 84.0% in patients with CHD and 20% in controls. Severe malnutrition was diagnosed in 71.4% of cases. All anthropometric measurements and levels of biochemical markers of nutritional state were significantly lower in the patients group compared to controls. In patients with acyanotic CHD, stunting was proportionately higher (57.89%) than in cyanotic CHD, while wasting was predominant (45.83%) in the latter. Malnutrition correlated significantly with low hemoglobin level, low arterial oxygen saturation, heart failure, pulmonary hypertension and poor dietary history. Conclusion: Malnutrition is a very common problem in children with symptomatic CHD and predicted by the presence of low hemoglobin level, low arterial oxygen saturation, heart failure, poor dietary history and pulmonary hypertension.
- 15 June 2015
- Published by Frontiers Media SA in Frontiers in Pediatrics
- Vol. 3, 53
Open AccessNutritional Status in Children with Un-Operated Congenital Heart Disease: An Egyptian Center Experience
Background: Malnutrition is a common cause of morbidity and mortality in children with congenital heart disease (CHD).This study aimed to identify prevalence and predictors of malnutrition in Egyptian children with symptomatic CHD. Methods: This case-control study included 100 children with symptomatic CHD (76 acyanotic and 24 cyanotic) and 100 age and sex-matched healthy children as a control group. Clinical Evaluation and Laboratory Assessment of Nutritional Status were done. Anthropometric measurements were recorded and Z scores for weight for age (WAZ), weight for height (WHZ) and height for age (HAZ) were calculated. Malnutrition was defined as weight, height and weight/ height z-score ≤ –2. Results: The overall prevalence of malnutrition was 84.0% in patients with CHD and 20% in controls. Severe malnutrition was diagnosed in 71.4% of cases. All anthropometric measurements and levels of biochemical markers of nutritional state were significantly lower in the patients group compared to controls. In patients with acyanotic CHD, stunting was proportionately higher (57.89%) than in cyanotic CHD, while wasting was predominant (45.83%) in the latter. Malnutrition correlated significantly with low hemoglobin level, low arterial oxygen saturation, heart failure, pulmonary hypertension and poor dietary history. Conclusion: Malnutrition is a very common problem in children with symptomatic CHD and predicted by the presence of low hemoglobin level, low arterial oxygen saturation, heart failure, poor dietary history and pulmonary hypertension.
- Open Access
- 25 March 2014
- Published by Frontiers Media SA in Frontiers in Pediatrics
- Vol. 2, 16
Non-Invasive Cardiac Output Measurement in Low and Very Low Birth Weight: A Method Comparison
Background : Cardiac output (CO) measurement in low (LBW) and very low (VLBW) birth weight infants is difficult. Hitherto, sporadical transthoracic echocardiography (TTE) is the only non-invasive measurement method. Electrical velocimetry (EV) has been evaluated as an alternative in normal weight newborns. Objectives: The study was designed to evaluate if EV could even be interchangeable with TTE in LBW and VLBW infants. Methods: In 28 (17 LBW, 11 VLBW) premature newborns, n = 228 simultaneous TTE (transaortic Doppler) and EV measurements (134 LBW, 94 VLBW) of stroke volume (SV) and heart rate (HR) were performed, thereof calculating body weight indexed SV (= SV*) and CO (= CO*) for all patients and the subgroups. Method comparison was performed by Bland-Altman plot, method precision expressed by calculation of the coefficient of variation (CV). Results: Mean CO* in all patients was 256.4 ± 44.8 (TTE) and 265.3 ± 48.8 (EV) ml/kg/min. Bias and precision were clinically acceptable, limits of agreement within the 30% criterion for method interchangeability (Critchley and Critchley, 1999). According to their different anatomic dimensions and pathophysiology, there were significant differences of SV(*), HR and CO* for LBW and VLBW infants as well for inotropic treatment and ventilation mode.Conclusions: Extending recent publications on EV/TTE comparison in newborns, this study suggests that EV is also applicable in LWB/VLBW infants as a safe and easy to handle method for continuous CO monitoring in the NICU and PCICU.
- 25 March 2014
- Published by Frontiers Media SA in Frontiers in Pediatrics
- Vol. 2, 16
Open AccessNon-Invasive Cardiac Output Measurement in Low and Very Low Birth Weight: A Method Comparison
Background : Cardiac output (CO) measurement in low (LBW) and very low (VLBW) birth weight infants is difficult. Hitherto, sporadical transthoracic echocardiography (TTE) is the only non-invasive measurement method. Electrical velocimetry (EV) has been evaluated as an alternative in normal weight newborns. Objectives: The study was designed to evaluate if EV could even be interchangeable with TTE in LBW and VLBW infants. Methods: In 28 (17 LBW, 11 VLBW) premature newborns, n = 228 simultaneous TTE (transaortic Doppler) and EV measurements (134 LBW, 94 VLBW) of stroke volume (SV) and heart rate (HR) were performed, thereof calculating body weight indexed SV (= SV*) and CO (= CO*) for all patients and the subgroups. Method comparison was performed by Bland-Altman plot, method precision expressed by calculation of the coefficient of variation (CV). Results: Mean CO* in all patients was 256.4 ± 44.8 (TTE) and 265.3 ± 48.8 (EV) ml/kg/min. Bias and precision were clinically acceptable, limits of agreement within the 30% criterion for method interchangeability (Critchley and Critchley, 1999). According to their different anatomic dimensions and pathophysiology, there were significant differences of SV(*), HR and CO* for LBW and VLBW infants as well for inotropic treatment and ventilation mode.Conclusions: Extending recent publications on EV/TTE comparison in newborns, this study suggests that EV is also applicable in LWB/VLBW infants as a safe and easy to handle method for continuous CO monitoring in the NICU and PCICU.
- 30 March 2012
- Published by Springer Nature in Intensive Care Medicine
- Vol. 38 (6) , 1032-1039
Electrical velocimetry as a tool for measuring cardiac output in small infants after heart surgery
Purpose Cardiac output (CO), the product of stroke volume (SV) and heart rate, is essential to guarantee organ perfusion, especially in the intensive care setting. As invasive measurement of CO bears the risk of complications there is a need for non-invasive alternatives. We investigated if electrical velocimetry (EV) and transthoracic Doppler (Doppler-TTE) are interchangeable for the non-invasive measurement of SV and able to reflect the post-surgical SV/CO trend. Methods Comparison of SV measurements by EV and Doppler-TTE was performed in 24 newborns after switch operation (n = 240 measurements). Three subgroups of measurements (=periods) were created according to the patients’ status in the course of post-surgical CO recovery. Results Bland–Altman analysis found acceptable bias and limits of agreement for the interchangeability of the two methods. Mean overall SV was 3.7 ml with a mean overall bias of 0.28 ml (=7.6 %). The mean percentage error of 29 % was acceptable according to the method of Critchley and Critchley. Overall precision expressed by the coefficient of variation (CV) was 6.6 % for SVTTE and 4.4 % for SVEV. SVTTE and SVEV medians in the three periods were significantly different and documented the post-surgical CO trend. Conclusions EV and Doppler-TTE are interchangeable for estimating SV. EV has the advantages of easy handling and allows continuous measurement.
- 30 March 2012
- Published by Springer Nature in Intensive Care Medicine
- Vol. 38 (6) , 1032-1039
Electrical velocimetry as a tool for measuring cardiac output in small infants after heart surgery
Purpose Cardiac output (CO), the product of stroke volume (SV) and heart rate, is essential to guarantee organ perfusion, especially in the intensive care setting. As invasive measurement of CO bears the risk of complications there is a need for non-invasive alternatives. We investigated if electrical velocimetry (EV) and transthoracic Doppler (Doppler-TTE) are interchangeable for the non-invasive measurement of SV and able to reflect the post-surgical SV/CO trend. Methods Comparison of SV measurements by EV and Doppler-TTE was performed in 24 newborns after switch operation (n = 240 measurements). Three subgroups of measurements (=periods) were created according to the patients’ status in the course of post-surgical CO recovery. Results Bland–Altman analysis found acceptable bias and limits of agreement for the interchangeability of the two methods. Mean overall SV was 3.7 ml with a mean overall bias of 0.28 ml (=7.6 %). The mean percentage error of 29 % was acceptable according to the method of Critchley and Critchley. Overall precision expressed by the coefficient of variation (CV) was 6.6 % for SVTTE and 4.4 % for SVEV. SVTTE and SVEV medians in the three periods were significantly different and documented the post-surgical CO trend. Conclusions EV and Doppler-TTE are interchangeable for estimating SV. EV has the advantages of easy handling and allows continuous measurement.