Theoretical analysis of full-ring multi-pinhole brain SPECT
Authors:
- M C GoordenMGM C Goorden
- M C M RentmeesterMRM C M Rentmeester
- F J BeekmanFBF J Beekman
- 14 October 2009
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (21) , 6593-6610
Abstract
Presently used clinical brain SPECT suffers from limited spatio-temporal resolution. Here we investigate the feasibility of high-resolution and high-sensitivity full-ring multi-pinhole brain SPECT (MP-SPECT). Using an analytical model we optimized pinhole-detector geometries of MP-SPECT for different detector intrinsic resolutions R(i). System resolution and sensitivity of optimized MP-SPECT were compared to conventional clinical SPECT. The comparison of the system resolution of different systems was done at matched sensitivity, which was achieved by tuning pinhole diameters. Similarly, sensitivities were compared at matched system resolution. For MP-SPECT that uses detectors with intrinsic resolutions of 4 mm > R(i) 0.5 mm a sensitivity can be achieved that is 6.0 times higher than the sensitivity of conventional dual-head SPECT systems with parallel-hole collimators (DualPar), while system resolution can be improved by a factor of 2.4. To achieve these improvements a large detector-to-collimator distance is needed. In contrast, for detectors with intrinsic resolutions 0) can have a system resolution that is 2.0 times better than optimized MP-SPECT with a conventional detector (R(i) approximately 3 mm). The high performance of optimized MP-SPECT may open up completely new molecular imaging applications.Keywords
This publication has 33 references indexed in Scilit:
- The pinhole: gateway to ultra-high-resolution three-dimensional radionuclide imagingEuropean Journal of Nuclear Medicine and Molecular Imaging, 2006
- Is brain imaging clinically useful for psychiatrists?Clinical Psychiatry News, 2006
- Combined 99mTc-ECD SPECT and neuropsychological studies in MCI for the assessment of conversion to ADNeurobiology of Aging, 2006
- Photon-counting gamma camera based on an electron-multiplying CCDIEEE Transactions on Nuclear Science, 2005
- Photon-counting versus an integrating CCD-based gamma camera: important consequences for spatial resolutionPhysics in Medicine & Biology, 2005
- Design and simulation of a high-resolution stationary SPECT system for small animalsPhysics in Medicine & Biology, 2004
- A monolithic array of silicon drift detectors coupled to a single scintillator for γ-ray imaging with sub-millimeter position resolutionNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003
- Analytic Determination of the Resolution-Equivalent Effective Diameter of a Pinhole CollimatorIEEE Transactions on Medical Imaging, 2002
- A cylindrical SPECT camera with de-centralized readout schemeNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2001
- Applications of semiconductor detectors to nuclear medicineNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1999