Spatial analysis of the impact of UVGI technology in occupied rooms using ray‐tracing simulation
Authors:
- 26 March 2021
- journal article
- research article
- Published by Wiley in Indoor Air
- Vol. 31 (5) , 1625-1638
Abstract
The use of Ultraviolet Germicidal Irradiation (UVGI) devices in the upper zones of occupied buildings has gained increased attention as one of the most effective mitigation technologies for the transmission of COVID‐19. To ensure safe and effective use of upper‐room UVGI, it is necessary to devise a simulation technique that enables engineers, designers, and users to explore the impact of different design and operational parameters. We have developed a simulation technique for calculating UV‐C fluence rate within the volume of the upper zone and planar irradiance in the lower occupied zone. Our method is based on established ray‐tracing light simulation methods adapted to the UV‐C wavelength range. We have included a case study of a typical hospital patient room. In it, we explored the impact of several design parameters: ceiling height, device location, room configuration, proportions, and surface materials. We present a spatially mapped parametric study of the UV‐C irradiance distribution in three dimensions. We found that the ceiling height and mounting height of the UVGI fixtures combined can cause the largest variation (up to 22%) in upper zone fluence rate. One of the most important findings of this study is that it is crucial to consider interreflections in the room. This is because surface reflectance is the design parameter with the largest impact on the occupant exposure in the lower zone: Applying materials with high reflectance ratio in the upper portion of the room has the highest negative impact (over 700% variation) on increasing hot spots that may receive over 6 mJ/cm2 UV dose in the lower occupied zone.Keywords
This publication has 28 references indexed in Scilit:
- Indoor environmental control of tuberculosis and other airborne infectionsIndoor Air, 2015
- Influence of ceiling fan's speed and direction on efficacy of upperroom, ultraviolet germicidal irradiation: ExperimentalBuilding and Environment, 2015
- Application of CFD Simulation to Predicting Upper‐Room UVGI EffectivenessPhotochemistry and Photobiology, 2012
- Ultraviolet Spectral Reflectance of Ceiling Tiles, and Implications for the Safe Use of Upper‐Room Ultraviolet Germicidal IrradiationPhotochemistry and Photobiology, 2012
- In Situ Measurement of UV Fluence Rate Distribution by Use of a Micro Fluorescent Silica DetectorEnvironmental Science & Technology, 2011
- Monitoring Human Exposures to Upper-Room Germicidal Ultraviolet IrradiationJournal of Occupational and Environmental Hygiene, 2005
- The use of ultraviolet germicidal irradiation (UVGI) in disinfection of airborne bacteriaEnvironmental Engineering and Policy, 2001
- Cubic illuminationLighting Research & Technology, 1997
- Development of Visualization System of Spatial Illuminance.Journal of Light & Visual Environment, 1997
- The Effect of Sunlight Upon Hydrogen Peroxide 2Nature, 1879