Stress-strain state of a thoracolumbar spine model with a Th12 type A1 vertebral fracture under short-segment pedicle fixation: analysis of compressive loading
Open Access
- 10 December 2025
- journal article
- Published by Publishing House Zaslavsky in TRAUMA
- Vol. 26 (6) , 393-402
Abstract
Background. Fractures of the thoracolumbar junction (Th11-L2) are among the most common spinal injuries and frequently lead to post-traumatic deformities and neurological complications. The most widespread surgical treatment is short-segment pedicle fixation; however, questions remain regarding the necessity of including the fractured vertebra in the construct and the optimal screw length. Objective: to evaluate the stress-strain state of the thoracolumbar spine with a Th12 vertebral body fracture of type A1 according to the AO Spine classification, and to determine the influence of the main pedicle screw length and the presence of intermediate screws in the fractured vertebra during short-segment fixation. Materials and methods. A three-dimensional finite element model of the thoracolumbar spine (Th9-L5) was constructed based on computed tomography data. A type A1 Th12 vertebral body fracture (AO Spine classification) was simulated. Four short-segment pedicle fixation configurations were analyzed: short screws without intermediate screws; long screws without intermediate screws; short screws with intermediate screws in the Th12 vertebral body; long screws with intermediate screws in the Th12 vertebral body. An axial compressive load of 350 N was applied. Stress distribution was analyzed using the finite element method according to the von Mises criterion. Results. The distribution of stresses in the vertebral bodies showed only minor variations (2–3 %) across the models. The basic four-screw construct provided sufficient unloading of the fractured vertebra. Adding intermediate screws reduced stress in the main screws, particularly at Th11, but doubled stress levels in the supporting rods. The use of long bicortical screws exerted a moderate unloading effect on the bony structures but increased stress within the screws themselves, especially at L1. Conclusions. In cases of type A1 compression fractures requiring surgical management, short-segment four-screw fixation ensures adequate spinal stability while minimizing the mechanical load on the fractured vertebra. The use of long screws and additional intermediate screws is more appropriate for severe injuries, whereas in simple compression fractures such modifications do not offer significant biomechanical advantages but increase surgical invasiveness.Keywords
This publication has 28 references indexed in Scilit:
- Risk factors for failure in short segment pedicle instrumentation in thoracolumbar fracturesBrain and Spine, 2025
- In vitro coupled motions of the whole human thoracic and lumbar spine with rib cageJOR SPINE, 2023
- Failure of Conservatively Managed Traumatic Vertebral Compression Fractures: A Systematic ReviewWorld Neurosurgery, 2022
- Pedicle screw fixation of thoracolumbar fractures: conventional short segment versus short segment with intermediate screws at the fracture level—a systematic review and meta-analysisEuropean Spine Journal, 2020
- A bicortical pedicle screw in the caudad trajectory is the best option for the fixation of an osteoporotic vertebra: An in-vitro experimental study using synthetic lumbar osteoporotic bone modelsClinical Biomechanics, 2020
- A Review of the Fatigue Properties of Additively Manufactured Ti-6Al-4VJOM, 2018
- The Thoracolumbar AOSpine Injury ScoreGlobal Spine Journal, 2015
- AOSpine Thoracolumbar Spine Injury Classification SystemSpine, 2013
- Inclusion of the fracture level in short segment fixation of thoracolumbar fracturesEuropean Spine Journal, 2010
- Mechanical biocompatibilities of titanium alloys for biomedical applicationsJournal of the Mechanical Behavior of Biomedical Materials, 2008