Abstract
Magnetic flux leakage (MFL) detection technology is often used for the inspection of steel wire ropes. Due to the weak leakage magnetic field, weak signal defects are often difficult to detect in MFL detection. For this problem, the influencing parameters that affect the sensitivity of the coil sensor are analyzed theoretically and experimentally, and a sensor suitable for weak signal defect detection is designed. On the other hand, magnetic sensitive direction adjustment method was introduced to suppress the strand signal. Based on the finite element simulation and experimental research results, the optimal direction adjustment angle of the magnetic sensitive direction was set. Based on the above design, a combined weak signal processing method based on morphological filtering, circumferential wavelet, and morphological reconstruction was further designed. The experimental results show that the proposed method of using magnetic sensitive direction adjustment to suppress strand signals combined with weak signal filtering can effectively enhance the quality of weak signals and improve the identifiability of defects. Both multi-case and comparative experiments have proved that the proposed method has good performance and effectively improves the detection rate of weak signal defects.
Funding Information
  • National Natural Science Foundation of China (52275532)
  • National Natural Science Foundation of China (52274159)
  • National Key Research and Development Program of China (2021YFF0501000)

This publication has 21 references indexed in Scilit: