The Asymmetrical Half Bridge converter (AHBC) has proven to be a promising candidate for LED lighting applications. It provides high efficiency, galvanic isolation and, at the same time, its output filter can be very small and, therefore, easily implemented without electrolytic capacitor. On the other hand, its main drawback is its poor attainable bandwidth. In any ac-dc LED lighting application, the input voltage of the AHBC is provided by a Power Factor Corrector (PFC) converter which has to be also implemented without electrolytic capacitor in order to assure the long lifetime of the whole LED driver. As a consequence, its output voltage (input voltage of the AHBC) is affected by a low-frequency ripple. Due to the poor bandwidth of the AHBC, this voltage ripple will be transferred to the converter output voltage, leading to flickering. A possible solution is using a feedforward loop for cancelling the effect of this low-frequency ripple without affecting stability. Due to the complex and non-linear transfer function of the AHBC, any analog feedforward loop has to be tuned for a given operating point, leading to a poor performance (i.e., high flickering, high ripple) when the AHBC moves away from that point. Dimming, which is a very frequent requirement in many LED drivers, implies large variations of the output voltage and, consequently, moving away from the aforementioned operating point. In this paper, a digital feedforward loop is proposed in order to solve this problem. The digital implementation allows the feedforward loop to perfectly cancel the ripple under any condition (e.g., output voltage variation due to dimming). Besides, despite its complex transfer function, this digital feedforward loop has been designed and optimized for its implementation in small-size microcontrollers. Experimental results with a 40-W prototype prove the usefulness of the proposed feedforward loop and the validity of the equations used in the optimized design.Keywords
This publication has 12 references indexed in Scilit:
- High-Efficiency Asymmetrical Half-Bridge Converter Without Electrolytic Capacitor for Low-Output-Voltage AC–DC LED DriversIEEE Transactions on Power Electronics, 2013
- A primary side control Scheme for Triac dimmable LED driver based on indirect output current sensing2012
- Elimination of an Electrolytic Capacitor in AC/DC Light-Emitting Diode (LED) Driver With High Input Power Factor and Constant Output CurrentIEEE Transactions on Power Electronics, 2012
- An Overview of the AC-DC and DC-DC Converters for LED Lighting ApplicationsAutomatika, 2012
- Proposing measures of flicker in the low frequencies for lighting applications2011
- LED lighting flicker and potential health concerns: IEEE standard PAR1789 update2010
- Means of Eliminating Electrolytic Capacitor in AC/DC Power Supplies for LED LightingsIEEE Transactions on Power Electronics, 2009
- Zero voltage switching in the PWM half bridge topology with complementary control and synchronous rectification1995
- An overall study of the half-bridge complementary-control DC-to-DC converter1995
- Optimized synchronous rectification stage for low output voltage (3.3 V) DC/DC conversion1994