Design and Testing of Pressure Ulcers Preventive Bed for Neonates in Neonatal Intensive Care Units
- 10 April 2023
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 5 (2) , 421-428
Abstract
In neonatal intensive care units (NICUs), preterm infants lie down immobile for long hours in a particular position, which makes them susceptible to develop pressure ulcers (PUs). These are developed due to continuous constant contact pressure generated by the self-weight of the infants with bed surfaces on their sensitive skin, which is 60% less than the thickness of an adult and hampers blood flow from the subcutaneous areas. Therefore, it is necessary to change the posture in a periodic manner. Hospitals manage the position changes by nursing staff, which is of limited effect and puts additional loads on them. Hence, in this paper, an anti-pressure ulcer bed was designed and tested to prevent pressure ulcers and also help in reducing the effort of nurses. The contact pressure of both the neonatal phantom and neonatal baby with the silicone-made bed surface was automatically varied by fluid pressure in the multi-channels based on the actuation mechanism (which rises alternately in inflated regions and falls in deflated regions), and it was measured using the force sensors. The demonstrated work was carried out in finite element modeling (FEM) using Abaqus to validate the results. We anticipate that itll reduce the risk of pressure ulcers, confirming the designed beds performance.Keywords
Funding Information
- Science and Engineering Research Board (SERB) of Government of India under the Start-Up Research Grant (SRG) Scheme (SRG/2020/000448)
This publication has 21 references indexed in Scilit:
- Comparing time and frequency domain estimation of neonatal respiratory rate using pressure-sensitive mats2017
- Global, regional, and national causes of under-5 mortality in 2000–15: an updated systematic analysis with implications for the Sustainable Development GoalsThe Lancet, 2016
- Characteristic analysis of an air cell for active air mattress of prevention for pressure ulcerAdvanced Robotics, 2014
- Innovation in prevention and treatment of pressure ulcer: Nursing implicationTropical Journal of Medical Research, 2014
- A Resource-Efficient Planning for Pressure Ulcer PreventionIEEE Transactions on Information Technology in Biomedicine, 2012
- Design of a smart textile mat to study pressure distribution on multiple foam material configurations2011
- Stress Analyses Coupled With Damage Laws to Determine Biomechanical Risk Factors for Deep Tissue Injury During SittingJournal of Biomechanical Engineering, 2008
- In Vivo Muscle Stiffening Under Bone Compression Promotes Deep Pressure SoresJournal of Biomechanical Engineering, 2005
- Transair® Paediatric Mattress replacement system evaluationBritish Journal of Nursing, 2002
- Decubitus prophylaxis: a prospective trial on the efficiency of alternating-pressure air-mattresses and water-mattressesActa Dermato-Venereologica, 1983