BBBijit Basumatary

Bijit Basumatary

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bijit Basumatary has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    AI-Enhanced FES for Foot Drop: A Novel Biphasic Charge-Balanced Stimulation Approach

    by Bijit Basumatary, Rajat Suvra Halder, Adarsha Narayan Mallick, Arun Khokhar, Rajinder Bansal, Rajesh Kumar, Ashish Kumar Sahani

    Foot drop is a neuromuscular condition that impairs a patient’s ability to lift their foot while walking, leading to gait abnormalities and increased fall risk. Functional Electrical Stimulation (FES) is a rehabilitation technique that stimulates the peroneal nerve to restore normal movement. However, existing FES devices often lack precise charge balancing and timing accuracy, which can cause patient discomfort and potential tissue damage. To address these challenges, we developed a wearable, compact, and AI-driven FES system capable of generating biphasic, charge-balanced, trapezoidal pulses. The system integrates an ESP32 microcontroller, an OPA452-based stimulation circuit, and machine learning algorithms for foot lift detection. Unlike traditional threshold-based detection methods, our AI-enhanced approach adapts stimulation timing in real-time, improving synchronization with the patient’s gait. Initial testing demonstrated the system’s ability to generate precise charge-balanced stimulation pulses while accurately detecting foot-lift events. The AI-based detection method improved timing accuracy, reducing unwanted stimulation and enhancing patient comfort. The proposed system offers a technological advancement in neurorehabilitation, addressing key limitations of existing FES solutions. By integrating machine learning with FES, this work introduces a personalized, intelligent stimulation system that enhances rehabilitation outcomes for individuals with foot drop. The developed FES system achieved an average accuracy of 92.2%. Stimulation was found to be smooth between 120-220 microseconds and 25-35 Hz.

  • Performance Evaluation of Neonatal Anti-Pressure Ulcer Bed Using a Novel Force-Sensing Array

    by Adarsha Narayan Mallick, Bijit Basumatary, Mukesh Kumar, Kamaldeep Arora, Durba Pal, Ashish Kumar Sahani

    Pressure ulcer (PU) is a serious issue among newborns, particularly those who are premature and have medical conditions that require hospitalization. Existing conventional beds require modifications that can reduce the chance of PU and the extra effort of nursing staff. In this work, a force-sensing resistor array (FSRA) mattress is implemented that detects high-pressure points. The microcontroller processes the data that are collected from the FSRA using an electronic circuit based on the principle of voltage divider circuits. The multiplexer identifies the pixels of high-pressure points and plots the heat maps using matlab. The results of the FSRA mattress use an alternately inflating and deflating pressure channel bed to act as an anti-PU bed and compare it with the currently deployed bed. The demonstrated work was validated using the finite element modeling framework. This anti-PU bed is effective in detecting high-pressure points; based on that, chances of PUs in neonates can be prevented. The performance evaluation of the designed and tested anti-PU bed with more accuracy and automatically varies the contact position to reduce the efforts made by the nursing staff. This innovation significantly improves the quality of life as compared to the conventional methods to avoid PUs for neonatal intensive care units (NICUs).


  • Deep Learning Approach for Gait Detection for Precise Stimulation of FES to Correct Foot Drop

    by Bijit Basumatary, Rajat Suvra Halder, Chirag Singhal, Adarsha Narayan Mallick, Arun Khokhar, Rajinder Bansal, Ashish Kumar Sahani


  • Open Access

    Development of a low-cost, compact, wireless, 16 - channel biopotential data acquisition, signal conditioning and arbitrary waveform stimulator

    by Rajat Suvra Halder, Bijit Basumatary, Ashish Sahani

    The health and fitness of the human body rely heavily on physiological parameters. These parameters can be measured using various tools such as ECG, EMG, EEG, EOG, among others, to obtain real-time physiological data. Analysing the bio-signals obtained from these measurements can provide valuable information that can be used to improve health-care in terms of observation, diagnosis, and treatment. In bio-signal pattern recognition applications, more channels provide multiple information simultaneously. Different biosignal acquisition devices are available in the market, most of which are designed for specific signals like ECG, EMG, EEG etc The gain of the amplifiers and frequency of the filters are designed as per the targeted signals; due to which one device cannot be used for other signals. Also, most of the systems are wired system which is not comfortable for animal studies. In this paper, a low-cost, compact, wireless, 16 channel biopotential data acquisition system with integrated electrical stimulator is designed and implemented. There are several novel and flexible design approaches were incorporated in the proposed design like (1) It has user selectable digital filter in each channel based on the signal frequencies like ECG, EMG, EEG, EOG. The same system will be used to acquire different signals simultaneously. (2) It has variable gain with a configurable analog bandpass filter. (3) It can acquire signals from 4 patients simultaneously. (4) The system is capable to acquire signal from both two-electrode as well as three-electrode configurations. (5) It has integrated stimulator with trapezoidal, charge-balanced, biphasic stimulus output with near zero DC level and user selectable pulse duration or frequency of the stimulus. The developed system has the ability to acquire and transmit data wirelessly in real-time at a high transfer rate. To validate the performance of the system, tests were conducted on the acquired signals using a simulator.


  • A Deep Learning-based System for Detecting Anemia from Eye Conjunctiva Images taken from a Smartphone

    by Pallavi, Bijit Basumatary, Rahul Shukla, Rakesh Kumar, Bodhisatwa Das, Ashish Kumar Sahani


  • Design and Testing of Pressure Ulcers Preventive Bed for Neonates in Neonatal Intensive Care Units

    by Adarsha Narayan Mallick, Mukesh Kumar, Bijit Basumatary, Kamaldeep Arora, Ashish Kumar Sahani

    In neonatal intensive care units (NICUs), preterm infants lie down immobile for long hours in a particular position, which makes them susceptible to develop pressure ulcers (PUs). These are developed due to continuous constant contact pressure generated by the self-weight of the infants with bed surfaces on their sensitive skin, which is 60% less than the thickness of an adult and hampers blood flow from the subcutaneous areas. Therefore, it is necessary to change the posture in a periodic manner. Hospitals manage the position changes by nursing staff, which is of limited effect and puts additional loads on them. Hence, in this paper, an anti-pressure ulcer bed was designed and tested to prevent pressure ulcers and also help in reducing the effort of nurses. The contact pressure of both the neonatal phantom and neonatal baby with the silicone-made bed surface was automatically varied by fluid pressure in the multi-channels based on the actuation mechanism (which rises alternately in inflated regions and falls in deflated regions), and it was measured using the force sensors. The demonstrated work was carried out in finite element modeling (FEM) using Abaqus to validate the results. We anticipate that itll reduce the risk of pressure ulcers, confirming the designed beds performance.


  • A Systematic Review on Muscle Stimulation Techniques

    by Nishtha Kashyap, Vinay Kumar Baranwal, Bijit Basumatary, Rajinder Bansal, Ashish Sahani

    The conventional procedure in retraining a muscle has been physiotherapy, but persistence is required, which often proves to be a limitation in most patients. The electrical stimulation technique has great potential in comparison to conventional methods that are employed in retraining muscles. The neuromuscular electrical stimulation method uses a device that sends electrical impulses to neurones. This input causes the muscle to contract. It can be used to re-educate or retrain a muscle. In this review article, how different types of stimulation strategies can be used for re-educating muscles in different diseased conditions is studied. The force and quality of the muscle contraction depend upon several parameters such as frequency, amplitude, pulse duration and waveforms of stimuli. The Analysis of parameters involved in different stimulation techniques can help in understanding how a particular muscle can be stimulated in different diseased conditions. There are several studies that have reported the efficacy of muscle stimulation strategies. In this review, we investigated 30 research studies that used the muscle stimulation method for re-educating muscle and discussed many considerations in context to muscle stimulation techniques: the stimulation strategies and parameters, electrodes and results. With this review, we investigated a potential intervention for re-educating muscle and tried to recognise the limitations and benefits of the current strategies involved.