IPEM topical report: the first UK survey of dose indices from radiotherapy treatment planning computed tomography scans for adult patients
- 1 September 2018
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (18) , 185008
Abstract
CT scans are an integral component of modern radiotherapy treatments, enabling the accurate localisation of the treatment target and organs-at-risk, and providing the tissue density information required for the calculation of dose in the treatment planning system. For these reasons, it is important to ensure exposures are optimised to give the required clinical image quality with doses that are as low as reasonably achievable. However, there is little guidance in the literature on dose levels in radiotherapy CT imaging either within the UK or internationally. This IPEM topical report presents the results of the first UK wide survey of dose indices in radiotherapy CT planning scans. Patient dose indices were collected for prostate, gynaecological, breast, lung 3D, lung 4D, brain and head and neck scans. Median values per scanner and examination type were calculated and national dose reference levels and ‘achievable levels’ of CT dose index (CTDI vol ), dose-length-product (DLP) and scan length are proposed based on the third quartile and median values of these distributions, respectively. A total of 68 radiotherapy CT scanners were included in this audit. The proposed dose reference levels for CTDI vol and DLP are; prostate 16 mGy and 570 mGy · cm, gynaecological 16 mGy and 610 mGy · cm, breast 10 mGy and 390 mGy · cm, lung 3D 14 mGy and 550 mGy · cm, lung 4D 63 mGy and 1750 mGy · cm, brain 50 mGy and 1500 mGy · cm and head and neck 49 mGy and 2150 mGy · cm. Significant variations in dose indices were noted, with head and neck and lung 4D yielding a factor of eighteen difference between the lowest and highest dose scanners. There was also evidence of some clustering in the data by scanner manufacturer, which may be indicative of a lack of local optimisation of individual systems to the clinical task. It is anticipated that providing this data to the UK and wider radiotherapy community will aid the optimisation of treatment planning CT scan protocols.Keywords
This publication has 8 references indexed in Scilit:
- Doses from cervical spine computed tomography (CT) examinations in the UKBritish Journal of Radiology, 2018
- Can CT scan protocols used for radiotherapy treatment planning be adjusted to optimize image quality and patient dose? A systematic reviewBritish Journal of Radiology, 2017
- A national survey of computed tomography doses in hybrid PET-CT and SPECT-CT examinations in the UKNuclear Medicine Communications, 2017
- Establishment of national diagnostic reference levels for breast cancer CT protocols in radiation therapyBritish Journal of Radiology, 2016
- A Comprehensive Method for Calculating Patient Effective Dose and Other Dosimetric Quantities From CT DICOM ImagesAmerican Journal of Roentgenology, 2012
- Volume CT Dose Index and Dose-Length Product Displayed during CT: What Good Are They?Radiology, 2011
- Quality assurance for computed-tomography simulators and the computed-tomography-simulation process: Report of the AAPM Radiation Therapy Committee Task Group No. 66Medical Physics, 2003
- American Association of Physicists in Medicine Radiation Therapy Committee Task Group 53: Quality assurance for clinical radiotherapy treatment planningMedical Physics, 1998