Assessment of Iodine Contrast-To-Noise Ratio in Virtual Monoenergetic Images Reconstructed from Dual-Source Energy-Integrating CT and Photon-Counting CT Data
Open Access
- 14 June 2022
- journal article
- research article
- Published by MDPI AG in Diagnostics
- Vol. 12 (6) , 1467
Abstract
To evaluate whether the contrast-to-noise ratio (CNR) of an iodinated contrast agent in virtual monoenergetic images (VMI) from the first clinical photon-counting detector (PCD) CT scanner is superior to VMI CNR from a dual-source dual-energy CT scanner with energy-integrating detectors (EID), two anthropomorphic phantoms in three different sizes (thorax and abdomen, QRM GmbH), in combination with a custom-built insert containing cavities filled with water, and water with 15 mg iodine/mL, were scanned on an EID-based scanner (Siemens SOMATOM Force) and on a PCD-based scanner (Siemens, NAEOTOM Alpha). VMI (range 40–100 keV) were reconstructed without an iterative reconstruction (IR) technique and with an IR strength of 60% for the EID technique (ADMIRE) and closest matching IR strengths of 50% and 75% for the PCD technique (QIR). CNR was defined as the difference in mean CT numbers of water, and water with iodine, divided by the root mean square value of the measured noise in water, and water with iodine. A two-sample t-test was performed to evaluate differences in CNR between images. A p-value < 0.05 was considered statistically significant. For VMI without IR and below 60 keV, the CNR of the PCD-based images at 120 and 90 kVp was up to 55% and 75% higher than the CNR of the EID-based images, respectively (p < 0.05). For VMI above 60 keV, CNRs of PCD-based images at both 120 and 90 kVp were up to 20% lower than the CNRs of EID-based images. Similar or improved performance of PCD-based images in comparison with EID-based images were observed for VMIs reconstructed with IR techniques. In conclusion, with PCD-CT, iodine CNR on low energy VMI (<60 keV) is better than with EID-CT.Keywords
This publication has 25 references indexed in Scilit:
- Review of an initial experience with an experimental spectral photon-counting computed tomography systemNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2017
- Spectral Photon-counting CT: Initial Experience with Dual–Contrast Agent K-Edge ColonographyRadiology, 2017
- Human Imaging With Photon Counting–Based Computed Tomography at Clinical Dose LevelsInvestigative Radiology, 2016
- Abdominal Imaging with Contrast-enhanced Photon-counting CT: First Human ExperienceRadiology, 2016
- Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical ApplicationsRadiology, 2015
- Assessment of an Advanced Image-Based Technique to Calculate Virtual Monoenergetic Computed Tomographic Images From a Dual-Energy Examination to Improve Contrast-To-Noise Ratio in Examinations Using Iodinated Contrast MediaInvestigative Radiology, 2014
- Dual-Energy CT–Based Monochromatic ImagingAmerican Journal of Roentgenology, 2012
- Effect of Low Tube Voltage on Image Quality, Radiation Dose, and Low-Contrast Detectability at Abdominal Multidetector CT: Phantom StudyJournal of Biomedicine and Biotechnology, 2012
- Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and ApproachesRadiology, 2010
- Coronary Artery Calcium: A Multi-institutional, Multimanufacturer International Standard for Quantification at Cardiac CTRadiology, 2007