    Improved assessment of the cochlear implant and temporal bone structures with ultra-high resolution photon-counting detector CT compared to conventional CT systems

    by Judith van der Bie, Anke W. van der Eerden, Aaike S. van Den Berg, Marcel L. Dijkshoorn, Marcel van Straten, Hylke F.E. van der Toom, Floris V.W.J. van Zijl, Joel de Groen, Robert Jan Pauw, Ronald Booij

    Purpose: This study evaluates the image quality of photon-counting detector CT (PCD-CT) compared to conventional CT systems in cochlear implant imaging and aims to determine optimal scan parameters. Methods: Three cochlear implant models were inserted into three post-mortem human specimen heads. Each head was scanned on three high-end CT systems: SOMATOM Edge, SOMATOM Force and NAEOTOM Alpha. A total of 192 reconstructions were obtained, including various tube voltages (120–150 kV), tin filtering, and slice thicknesses (0.2–0.6 mm). For each scanner, multiple reconstruction kernels were applied. Contrast-to-noise ratios (CNR) for bone-to-soft-tissue were calculated. Two radiologists independently assessed anatomy, implant visibility, and overall image quality on a 5-point Likert scale and scored diagnostic confidence for detecting anatomic dehiscence. Results: PCD-CT showed significantly higher image quality scores across implant, anatomy, and general image quality compared to the Edge and Force ( p < 0.001). PCD-CT also produced significantly higher CNR (mean 23.5 vs. 13.8 [Edge] and 12.7 [Force]) and greater diagnostic confidence. For PCD-CT, optimal image quality was achieved using 0.2 mm slice thickness and the Hr89 kernel at 140 kV. PCD-CT scans acquired with half dose (27.5 mGy) showed no significant difference in CNRs but led to slightly lower subjective scores compared to standard-dose imaging. Conclusion: PCD-CT provides superior image quality and diagnostic confidence in cochlear implant imaging compared to the Edge and Force. Optimal results are achieved using 140 kV, 0.2 mm slices, and the Hr89 kernel. Although dose reduction is feasible, it slightly compromises subjective image quality.

  • Top Cited Papers
    Open Access

    Photon-counting CT: An updated review of clinical results

    by Judith van der Bie, Thom van der Laan, Marcel van Straten, Ronald Booij, Daniel Bos, Marcel L. Dijkshoorn, Alexander Hirsch, Edwin H.G. Oei, Ricardo P.J. Budde


  • Open Access

    Image quality assessment of coronary artery segments using ultra-high resolution dual source photon-counting detector computed tomography

    by Judith van der Bie, Simran P. Sharma, Marcel van Straten, Alexander Hirsch, Putri Annisa Kamila, Daniel Bos, Marcel L. Dijkshoorn, Ronald Booij, Ricardo P.J. Budde


  • Top Cited Papers
    Open Access

    Photon-counting CT: Review of initial clinical results

    by Judith van der Bie, Marcel van Straten, Ronald Booij, Daniel Bos, Marcel L. Dijkshoorn, Alexander Hirsch, Simran P. Sharma, Edwin H.G. Oei, Ricardo P.J. Budde


  • Open Access

    Assessment of Iodine Contrast-To-Noise Ratio in Virtual Monoenergetic Images Reconstructed from Dual-Source Energy-Integrating CT and Photon-Counting CT Data

    by Ronald Booij, Niels R. van der Werf, Marcel L. Dijkshoorn, Aad van der Lugt, Marcel van Straten

    To evaluate whether the contrast-to-noise ratio (CNR) of an iodinated contrast agent in virtual monoenergetic images (VMI) from the first clinical photon-counting detector (PCD) CT scanner is superior to VMI CNR from a dual-source dual-energy CT scanner with energy-integrating detectors (EID), two anthropomorphic phantoms in three different sizes (thorax and abdomen, QRM GmbH), in combination with a custom-built insert containing cavities filled with water, and water with 15 mg iodine/mL, were scanned on an EID-based scanner (Siemens SOMATOM Force) and on a PCD-based scanner (Siemens, NAEOTOM Alpha). VMI (range 40–100 keV) were reconstructed without an iterative reconstruction (IR) technique and with an IR strength of 60% for the EID technique (ADMIRE) and closest matching IR strengths of 50% and 75% for the PCD technique (QIR). CNR was defined as the difference in mean CT numbers of water, and water with iodine, divided by the root mean square value of the measured noise in water, and water with iodine. A two-sample t-test was performed to evaluate differences in CNR between images. A p-value < 0.05 was considered statistically significant. For VMI without IR and below 60 keV, the CNR of the PCD-based images at 120 and 90 kVp was up to 55% and 75% higher than the CNR of the EID-based images, respectively (p < 0.05). For VMI above 60 keV, CNRs of PCD-based images at both 120 and 90 kVp were up to 20% lower than the CNRs of EID-based images. Similar or improved performance of PCD-based images in comparison with EID-based images were observed for VMIs reconstructed with IR techniques. In conclusion, with PCD-CT, iodine CNR on low energy VMI (<60 keV) is better than with EID-CT.


  • Open Access

    Transthoracic 3D echocardiographic left heart chamber quantification in patients with bicuspid aortic valve disease

    by Allard T Van Den Hoven, Jackie S Mc-Ghie, Raluca G Chelu, Anthonie L Duijnhouwer, Vivan J M Baggen, Adriaan Coenen, Wim B Vletter, Marcel L Dijkshoorn, Annemien E Van Den Bosch, Jolien W Roos-Hesselink

    Integration of volumetric heart chamber quantification by 3D echocardiography into clinical practice has been hampered by several factors which a new fully automated algorithm (Left Heart Model, (LHM)) may help overcome. This study therefore aims to evaluate the feasibility and accuracy of the LHM software in quantifying left atrial and left ventricular volumes and left ventricular ejection fraction in a cohort of patients with a bicuspid aortic valve. Patients with a bicuspid aortic valve were prospectively included. All patients underwent 2D and 3D transthoracic echocardiography and computed tomography. Left atrial and ventricular volumes were obtained using the automated program, which did not require manual contour detection. For comparison manual and semi-automated measurements were performed using conventional 2D and 3D datasets. 53 patients were included, in four of those patients no 3D dataset could be acquired. Additionally, 12 patients were excluded based on poor imaging quality. Left ventricular end-diastolic and end-systolic volumes and ejection fraction calculated by the LHM correlated well with manual 2D and 3D measurements (Pearson’s r between 0.43 and 0.97, p < 0.05). Left atrial volume (LAV) also correlated significantly although LHM did estimate larger LAV compared to both 2DE and 3DE (Pearson’s r between 0.61 and 0.81, p < 0.01). The fully automated software works well in a real-world setting and helps to overcome some of the major hurdles in integrating 3D analysis into daily practice, as it is user-independent and highly reproducible in a group of patients with a clearly defined and well-studied valvular abnormality.


  • Open Access

    Efficacy of a dynamic collimator for overranging dose reduction in a second- and third-generation dual source CT scanner

    by Ronald Booij, Marcel L. Dijkshoorn, Marcel van Straten

    Objectives The purpose of this study was to assess the efficacy of the renewed dynamic collimator in a third-generation dual source CT (DSCT) scanner and to determine the improvements over the second-generation scanner. Methods Collimator efficacy is defined as the percentage overranging dose in terms of dose–length product (DLP) that is blocked by the dynamic collimator relative to the total overranging dose in case of a static collimator. Efficacy was assessed at various pitch values and different scan lengths. The number of additional rotations due to overranging and effective scan length were calculated on the basis of reported scanning parameters. On the basis of these values, the efficacy of the collimator was calculated. Results The second-generation scanner showed decreased performance of the dynamic collimator at increasing pitch. Efficacy dropped to 10% at the highest pitch. For the third-generation scanner the efficacy remained above 50% at higher pitch. Noise was for some pitch values slightly higher at the edge of the imaged volume, indicating a reduced scan range to reduce the overranging dose. Conclusions The improved dynamic collimator in the third-generation scanner blocks the overranging dose for more than 50% and is more capable of shielding radiation dose, especially in high pitch scan modes. Key points • Overranging dose is to a large extent blocked by the dynamic collimator • Efficacy is strongly improved within the third-generation DSCT scanner • Reducing the number of additional rotations can reduce overranging with increased noise


  • Cardiovascular imaging in pediatric patients using dual source CT

    by Ronald Booij, Marcel L. Dijkshoorn, Marcel van Straten, Frederik A. du Plessis, Ricardo P.J. Budde, Adriaan Moelker, Gabriel P. Krestin, Mohamed Ouhlous