Marcel van Straten has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Improved assessment of the cochlear implant and temporal bone structures with ultra-high resolution photon-counting detector CT compared to conventional CT systems

    by Judith van der Bie, Anke W. van der Eerden, Aaike S. van Den Berg, Marcel L. Dijkshoorn, Marcel van Straten, Hylke F.E. van der Toom, Floris V.W.J. van Zijl, Joel de Groen, Robert Jan Pauw, Ronald Booij

    Purpose: This study evaluates the image quality of photon-counting detector CT (PCD-CT) compared to conventional CT systems in cochlear implant imaging and aims to determine optimal scan parameters. Methods: Three cochlear implant models were inserted into three post-mortem human specimen heads. Each head was scanned on three high-end CT systems: SOMATOM Edge, SOMATOM Force and NAEOTOM Alpha. A total of 192 reconstructions were obtained, including various tube voltages (120–150 kV), tin filtering, and slice thicknesses (0.2–0.6 mm). For each scanner, multiple reconstruction kernels were applied. Contrast-to-noise ratios (CNR) for bone-to-soft-tissue were calculated. Two radiologists independently assessed anatomy, implant visibility, and overall image quality on a 5-point Likert scale and scored diagnostic confidence for detecting anatomic dehiscence. Results: PCD-CT showed significantly higher image quality scores across implant, anatomy, and general image quality compared to the Edge and Force ( p < 0.001). PCD-CT also produced significantly higher CNR (mean 23.5 vs. 13.8 [Edge] and 12.7 [Force]) and greater diagnostic confidence. For PCD-CT, optimal image quality was achieved using 0.2 mm slice thickness and the Hr89 kernel at 140 kV. PCD-CT scans acquired with half dose (27.5 mGy) showed no significant difference in CNRs but led to slightly lower subjective scores compared to standard-dose imaging. Conclusion: PCD-CT provides superior image quality and diagnostic confidence in cochlear implant imaging compared to the Edge and Force. Optimal results are achieved using 140 kV, 0.2 mm slices, and the Hr89 kernel. Although dose reduction is feasible, it slightly compromises subjective image quality.

  • Open Access

    Detectability and Volumetric Accuracy of Pulmonary Nodules in Low-Dose Photon-Counting Detector Computed Tomography: An Anthropomorphic Phantom Study

    by Joost F. Hop, Anna N. H. Walstra, Gert-Jan Pelgrim, Xueqian Xie, Noor A. Panneman, Niels W. Schurink, Sebastian Faby, Marcel van Straten, Geertruida H. de Bock, Rozemarijn Vliegenthart, et al.

    The aim of this phantom study was to assess the detectability and volumetric accuracy of pulmonary nodules on photon-counting detector CT (PCD-CT) at different low-dose levels compared to conventional energy-integrating detector CT (EID-CT). In-house fabricated artificial nodules of different shapes (spherical, lobulated, spiculated), sizes (2.5–10 mm and 5–1222 mm3), and densities (−330 HU and 100 HU) were randomly inserted into an anthropomorphic thorax phantom. The phantom was scanned with a low-dose chest protocol with PCD-CT and EID-CT, in which the dose with PCD-CT was lowered from 100% to 10% with respect to the EID-CT reference dose. Two blinded observers independently assessed the CT examinations of the nodules. A third observer measured the nodule volumes using commercial software. The influence of the scanner type, dose, observer, physical nodule volume, shape, and density on the detectability and volumetric accuracy was assessed by a multivariable regression analysis. In 120 CT examinations, 642 nodules were present. Observer 1 and 2 detected 367 (57%) and 289 nodules (45%), respectively. With PCD-CT and EID-CT, the nodule detectability was similar. The physical nodule volumes were underestimated by 20% (range 8–52%) with PCD-CT and 24% (range 9–52%) with EID-CT. With PCD-CT, no significant decrease in the detectability and volumetric accuracy was found at dose reductions down to 10% of the reference dose (p > 0.05). The detectability and volumetric accuracy were significantly influenced by the observer, nodule volume, and a spiculated nodule shape (p < 0.05), but not by dose, CT scanner type, and nodule density (p > 0.05). Low-dose PCD-CT demonstrates potential to detect and assess the volumes of pulmonary nodules, even with a radiation dose reduction of up to 90%.


  • Top Cited Papers
    Open Access

    Photon-counting CT: Review of initial clinical results

    by Judith van der Bie, Marcel van Straten, Ronald Booij, Daniel Bos, Marcel L. Dijkshoorn, Alexander Hirsch, Simran P. Sharma, Edwin H.G. Oei, Ricardo P.J. Budde


  • Open Access

    Assessment of Iodine Contrast-To-Noise Ratio in Virtual Monoenergetic Images Reconstructed from Dual-Source Energy-Integrating CT and Photon-Counting CT Data

    by Ronald Booij, Niels R. van der Werf, Marcel L. Dijkshoorn, Aad van der Lugt, Marcel van Straten

    To evaluate whether the contrast-to-noise ratio (CNR) of an iodinated contrast agent in virtual monoenergetic images (VMI) from the first clinical photon-counting detector (PCD) CT scanner is superior to VMI CNR from a dual-source dual-energy CT scanner with energy-integrating detectors (EID), two anthropomorphic phantoms in three different sizes (thorax and abdomen, QRM GmbH), in combination with a custom-built insert containing cavities filled with water, and water with 15 mg iodine/mL, were scanned on an EID-based scanner (Siemens SOMATOM Force) and on a PCD-based scanner (Siemens, NAEOTOM Alpha). VMI (range 40–100 keV) were reconstructed without an iterative reconstruction (IR) technique and with an IR strength of 60% for the EID technique (ADMIRE) and closest matching IR strengths of 50% and 75% for the PCD technique (QIR). CNR was defined as the difference in mean CT numbers of water, and water with iodine, divided by the root mean square value of the measured noise in water, and water with iodine. A two-sample t-test was performed to evaluate differences in CNR between images. A p-value < 0.05 was considered statistically significant. For VMI without IR and below 60 keV, the CNR of the PCD-based images at 120 and 90 kVp was up to 55% and 75% higher than the CNR of the EID-based images, respectively (p < 0.05). For VMI above 60 keV, CNRs of PCD-based images at both 120 and 90 kVp were up to 20% lower than the CNRs of EID-based images. Similar or improved performance of PCD-based images in comparison with EID-based images were observed for VMIs reconstructed with IR techniques. In conclusion, with PCD-CT, iodine CNR on low energy VMI (<60 keV) is better than with EID-CT.


  • Open Access

    Dose Reduction in Coronary Artery Calcium Scoring Using Mono-Energetic Images from Reduced Tube Voltage Dual-Source Photon-Counting CT Data: A Dynamic Phantom Study

    by Niels R. van der Werf, Margo van Gent, Ronald Booij, Daniel Bos, Aad van der Lugt, Ricardo P. J. Budde, Marcel J. W. Greuter, Marcel van Straten

    In order to assess coronary artery calcium (CAC) quantification reproducibility for photon-counting computed tomography (PCCT) at reduced tube potential, an anthropomorphic thorax phantom with low-, medium-, and high-density CAC inserts was scanned with PCCT (NAEOTOM Alpha, Siemens Healthineers) at two heart rates: 0 and 60–75 beats per minute (bpm). Five imaging protocols were used: 120 kVp standard dose (IQ level 16, reference), 90 kVp at standard (IQ level 16), 75% and 45% dose and tin-filtered 100 kVp at standard dose (IQ level 16). Each scan was repeated five times. Images were reconstructed using monoE reconstruction at 70 keV. For each heart rate, CAC values, quantified as Agatston scores, were compared with the reference, whereby deviations >10% were deemed clinically relevant. Reference protocol radiation dose (as volumetric CT dose index) was 4.06 mGy. Radiation dose was reduced by 27%, 44%, 67%, and 46% for the 90 kVp standard dose, 90 kVp 75% dose, 90 kVp 45% dose, and Sn100 standard dose protocol, respectively. For the low-density CAC, all reduced tube current protocols resulted in clinically relevant differences with the reference. For the medium- and high-density CAC, the implemented 90 kVp protocols and heart rates revealed no clinically relevant differences in Agatston score based on 95% confidence intervals. In conclusion, PCCT allows for reproducible Agatston scores at a reduced tube voltage of 90 kVp with radiation dose reductions up to 67% for medium- and high-density CAC.


  • Open Access

    Efficacy of a dynamic collimator for overranging dose reduction in a second- and third-generation dual source CT scanner

    by Ronald Booij, Marcel L. Dijkshoorn, Marcel van Straten

    Objectives The purpose of this study was to assess the efficacy of the renewed dynamic collimator in a third-generation dual source CT (DSCT) scanner and to determine the improvements over the second-generation scanner. Methods Collimator efficacy is defined as the percentage overranging dose in terms of dose–length product (DLP) that is blocked by the dynamic collimator relative to the total overranging dose in case of a static collimator. Efficacy was assessed at various pitch values and different scan lengths. The number of additional rotations due to overranging and effective scan length were calculated on the basis of reported scanning parameters. On the basis of these values, the efficacy of the collimator was calculated. Results The second-generation scanner showed decreased performance of the dynamic collimator at increasing pitch. Efficacy dropped to 10% at the highest pitch. For the third-generation scanner the efficacy remained above 50% at higher pitch. Noise was for some pitch values slightly higher at the edge of the imaged volume, indicating a reduced scan range to reduce the overranging dose. Conclusions The improved dynamic collimator in the third-generation scanner blocks the overranging dose for more than 50% and is more capable of shielding radiation dose, especially in high pitch scan modes. Key points • Overranging dose is to a large extent blocked by the dynamic collimator • Efficacy is strongly improved within the third-generation DSCT scanner • Reducing the number of additional rotations can reduce overranging with increased noise


  • Multicentre chest computed tomography standardisation in children and adolescents with cystic fibrosis: the way forward

    by Wieying Kuo, Mariette P C Kemner-Van De Corput, Adria Perez-Rovira, Marleen De Bruijne, Isabelle Fajac, Harm A W M Tiddens, Marcel Van Straten, ECFS-CTN/SCIFI CF study group

    Progressive cystic fibrosis (CF) lung disease is the main cause of mortality in CF patients. CF lung disease starts in early childhood. With current standards of care, respiratory function remains largely normal in children and more sensitive outcome measures are needed to monitor early CF lung disease. Chest CT is currently the most sensitive imaging modality to monitor pulmonary structural changes in children and adolescents with CF. To quantify structural lung disease reliably among multiple centres, standardisation of chest CT protocols is needed. SCIFI CF (Standardised Chest Imaging Framework for Interventions and Personalised Medicine in CF) was founded to characterise chest CT image quality and radiation doses among 16 participating European CF centres in 10 different countries. We aimed to optimise CT protocols in children and adolescents among several CF centres. A large variety was found in CT protocols, image quality and radiation dose usage among the centres. However, the performance of all CT scanners was found to be very similar, when taking spatial resolution and radiation dose into account. We conclude that multicentre standardisation of chest CT in children and adolescents with CF can be achieved for future clinical trials.


  • Cardiovascular imaging in pediatric patients using dual source CT

    by Ronald Booij, Marcel L. Dijkshoorn, Marcel van Straten, Frederik A. du Plessis, Ricardo P.J. Budde, Adriaan Moelker, Gabriel P. Krestin, Mohamed Ouhlous


  • Three-Section Expiratory CT: Insufficient for Trapped Air Assessment in Patients with Cystic Fibrosis?

    by Martine Loeve, Marleen de Bruijne, Ieneke C. J. Hartmann, Marcel van Straten, Wim C. J. Hop, Harm A. W. M. Tiddens

    Purpose: To estimate the effect of the number of computed tomography (CT) sections on trapped air (TA) assessment in patients with cystic fibrosis (CF) by using an established scoring system and a new quantitative scoring system and to compare CT and pulmonary function test (PFT) estimates of TA in a cross-sectional and longitudinal study. Materials and Methods: In this institutional review board-approved pilot study, 20 subjects aged 6-20 years (12 female and eight male; median age, 12.6 years) contributed two expiratory CT studies (three-section baseline CT, volumetric follow-up CT) and two PFT studies over 2 years after parental informed consent was obtained. From follow-up CT studies, seven sets were composed: Set 1 was volumetric. Sets 2, 3, 4, and 5, had spacing of 2.4, 4.8, 9.6, and 20.4 mm, respectively, between sections. Sets 6 and 7 contained five and three sections, respectively. Longitudinal follow-up was performed with three sections. All images were deidentified and randomized, and TA was scored with the Brody II system and a new quantitative system. Statistical analysis included the Wilcoxon signed rank test, calculation of Spearman and intraclass correlation coefficients, and use of three-section and linear mixed models. Results: For the Brody II system, the intraclass correlation coefficient for set 1 versus those for sets 2 through 7 was 0.75 versus 0.87; however, mean scores from sets 6 and 7 were significantly lower than the mean score from set 1 (P = .01 and P < .001, respectively). For the quantitative system, the number of sections did not affect TA assessment (intraclass correlation coefficient range, 0.82-0.88; P > .13 for all). CT and PFT estimates were not correlated (r s = 20.19 to 0.09, P = .43-.93). No change in TA over time was found for CT or PFT (P > .16 for all). Conclusion: The number of sections affected Brody II estimates, suggesting that three-section protocols lead to underestimation of TA assessment in patients with CF when using the Brody II system; CT and PFT estimates of TA showed no correlation and no significant change over time