Open Access
- 21 November 2022
- journal article
- research article
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 23 (22) , 14444
Abstract
Bionic-engineered tissues have been proposed for testing the performance of cardiovascular medical devices and predicting clinical outcomes ex vivo. Progress has been made in the development of compliant electronics that are capable of monitoring treatment parameters and being coupled to engineered tissues; however, the scale of most engineered tissues is too small to accommodate the size of clinical-grade medical devices. Here, we show substantial progress toward bionic tissues for evaluating cardiac ablation tools by generating a centimeter-scale human cardiac disk and coupling it to a hydrogel-based soft-pressure sensor. The cardiac tissue with contiguous electromechanical function was made possible by our recently established method to 3D bioprint human pluripotent stem cells in an extracellular matrix-based bioink that allows for in situ cell expansion prior to cardiac differentiation. The pressure sensor described here utilized electrical impedance tomography to enable the real-time spatiotemporal mapping of pressure distribution. A cryoablation tip catheter was applied to the composite bionic tissues with varied pressure. We found a close correlation between the cell response to ablation and the applied pressure. Under some conditions, cardiomyocytes could survive in the ablated region with more rounded morphology compared to the unablated controls, and connectivity was disrupted. This is the first known functional characterization of living human cardiomyocytes following an ablation procedure that suggests several mechanisms by which arrhythmia might redevelop following an ablation. Thus, bionic-engineered testbeds of this type can be indicators of tissue health and function and provide unique insight into human cell responses to ablative interventions.Keywords
Funding Information
- MnDRIVE Initiative on Robotics, Sensors, and Advanced Manufacturing
- Medtronic (Contract# 75772)
This publication has 59 references indexed in Scilit:
- Stretchable, Transparent, Ionic ConductorsScience, 2013
- Hybrid Gel Composed of Native Heart Matrix and Collagen Induces Cardiac Differentiation of Human Embryonic Stem Cells without Supplemental Growth FactorsJournal of Cardiovascular Translational Research, 2011
- Materials for multifunctional balloon catheters with capabilities in cardiac electrophysiological mapping and ablation therapyNature Materials, 2011
- Cryoablation Versus Radiofrequency Energy for the Ablation of Atrioventricular Nodal Reentrant Tachycardia (the CYRANO Study)Circulation, 2010
- Importance of Catheter Contact Force During Irrigated Radiofrequency Ablation: Evaluation in a Porcine Ex Vivo Model Using a Force‐Sensing CatheterJournal of Cardiovascular Electrophysiology, 2010
- Lethal Isotherms of Cryoablation in a Phantom Study: Effects of Heat Load, Probe Size, and NumberJournal of Vascular and Interventional Radiology, 2009
- Contrasting Effects of Convective Flow on Catheter Ablation Lesion Size: Cryo Versus Radiofrequency EnergyPacing and Clinical Electrophysiology, 2008
- Transcatheter Cryoablation Part II: Clinical UtilityPacing and Clinical Electrophysiology, 2008
- Indication of the radiofrequency induced lesion size by pre-ablation measurementsEP Europace, 2005
- Cryocatheter Ablation of Right Ventricular Outflow Tract TachycardiaJournal of Cardiovascular Electrophysiology, 2005