A comparative study of sheathing devices to increase robustness in inductively coupled plasma optical emission spectrometry via a nitrogen flow
Open Access
- 22 May 2018
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 33 (7) , 1269-1273
Abstract
Five different glass sheathing devices were used to introduce 20 mL min−1 N2 sheathing gas around the effluent from the spray chamber to see the effect of their dimensions on plasma robustness as measured using the Mg II 280.270 nm/Mg I 285.213 nm emission signal ratio in inductively coupled plasma (ICP) optical emission spectrometry (OES). A clear relationship between device dimensions and the plasma robustness profile along the ICP central channel was observed. With an aerosol inlet having an inner diameter of 1.0 cm in the sheathing device, mixing of N2 with the aerosol was minimised and the resulting sheath increased robustness, the higher thermal conductivity of N2versus Ar likely improving energy transfer between the bulk plasma and the central channel. The configuration of the outlet is also important, as any bottleneck favours mixing of N2 with the aerosol, which in turn cools the plasma, thereby shifting the region of maximum robustness to higher above the load coil. Regardless of device dimensions, plasma robustness was always better with N2 sheathing gas. An increased ion-to-atom emission signal ratio also resulted for other elements than Mg. The presence of N2 also seems to affect excitation mechanisms, such as charge transfer between NO+ and Cd or Ni, which appears to take place at higher observation height, after N2 has had enough time to diffuse into the central channel.Keywords
Funding Information
- Natural Sciences and Engineering Research Council of Canada (39487-2013)
- Conselho Nacional de Desenvolvimento Científico e Tecnológico (201398/2015-0)
This publication has 19 references indexed in Scilit:
- Environmental analysis by inductively coupled plasma mass spectrometryMass Spectrometry Reviews, 2009
- Exploration of robust operating conditions in inductively coupled plasma mass spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 2003
- The effect of sodium on analyte ionic line intensities in inductively coupled plasma atomic emission spectrometry: influence of the operating conditionsSpectrochimica Acta Part B: Atomic Spectroscopy, 1997
- Influence of the operating conditions on the efficiency of internal standardization in inductively coupled plasma atomic emission spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 1997
- Use of magnesium as a test element for inductively coupled plasma atomic emission spectrometry diagnosticsAnalytica Chimica Acta, 1991
- Investigations on mixed-gas plasmas produced by adding nitrogen to the plasma gas in ICP-MSSpectrochimica Acta Part B: Atomic Spectroscopy, 1991
- Improvement of the energy transfer with added-hydrogen in inductively coupled plasma atomic emission spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 1989
- Trace element analysis of organic solutions using inductively coupled plasma-mass spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 1987
- Transfer of energy between the surrounding plasma and the central channel in inductively coupled plasma-atomic emission spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 1987
- Determination of the rare-earth elements in geological materials by inductively coupled plasma mass spectrometryAnalytical Chemistry, 1987