Suyan Bi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Suyan Bi has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Zhitao Dai
Cancer Hospital Chinese Academy of Medical Sciences
3 shared publications Rui Zhu
Yunyang County People’s Hospital
2 shared publications- Ahmad Lutfi Bin Yusoff
Department of Nuclear Medicine Radiotherapy & Oncology School of Medical Sciences Universiti Sains Malaysia, Health Campus Kubang Kerian Kelantan Malaysia
1 shared publication Bo Yuan
Yunyang County People’s Hospital
1 shared publicationEn Lou
Department of Physics and Key Laboratory of Artificial Micro & Nano‐structures of Ministry of Education School of Physics and Technology Wuhan University Wuhan China
1 shared publicationHuanzi Jiang
Yunyang County People’s Hospital
1 shared publication
Latest Publications
- Open Access
- 27 February 2026
- Published by Elsevier in SSRN Electronic Journal
SFRT vs CRT/SBRT: A Clinical Trials Simulated (CTS) Study on Short-Term Objective Response Rate, Long-Term Local Control Rate, and Efficacy Gain Prediction for Bulky Tumors
Background: Spatially Fractionated Radiation Therapy (SFRT) is a promising modality for bulky tumors (≥5 cm) and lesions adjacent to critical organs-at-risk (OARs), but existing evidence lacks systematic evaluation of its long-term efficacy, subtype heterogeneity, and priority indications.Purpose: This clinical trial simulation (CTS) integrates meta-analysis, the Linear- Quadratic (LQ) model, and Weibull survival model to exclusively assess SFRT’s therapeutic profile, addressing core evidence gaps of SFRT-focused research.Materials and Methods: A SFRT-centric analytical framework was established: (1) Meta-analysis of 19 eligible studies (17 high-quality, 2 moderate-quality) covering 5 SFRT subtypes (LRT, GRID, proton SFGRT, 3D-SFRT, SBRT-PATHY); (2) Subgroup analyses by SFRT subtype, tumor site (bone metastases, visceral metastases, primary tumors), and tumor size (bulky ≥5 cm vs non-bulky <5 cm); (3) Mathematical modeling (LQ model for BED-3-year LCR correlation; Weibull model for long-term OS extrapolation) to fill data gaps. Sensitivity analyses (radiobiological parameter adjustment, alternative statistical models) verified robustness.Results: SFRT exhibited robust long-term efficacy: The LQ model (R²=0.98) confirmed a strong BED-LCR correlation, with a median BED of 78.4 Gy (65.2–95.5 Gy) predicting a 3-year LCR of 77.9% (95%CI:71.5–84.3%). Among subtypes, LRT achieved the highest 3-year LCR (81.3% [95%CI:74.5–88.1%]) and lowest Grade 3+ toxicity (8.5%), followed by proton SFGRT (72.5%, 12.3%) and GRID (68.7%, 15.7%). SFRT showed prominent benefits in bone metastases (3-month pain relief rate=70.0%), visceral metastases (3-year LCR=78.5% [95%CI:69.8–87.2%], 0% OAR dose violation), and bulky tumors (3-year LCR=74.3% [95%CI:66.8–81.8%]). Weibull extrapolation revealed SFRT’s survival profile in advanced lesions: 3-year OS of 27.9% (95%CI:6.1–49.7%) for advanced bulky cervical cancer and 12.9% (95%CI:7.4–18.4%) for bone metastases. Pooled Grade 3+ toxicity of SFRT was 10.2% (95%CI:6.8–15.4%) with no Grade 4–5 toxicity, dominated by mild fatigue and dermatitis.Conclusions: SFRT demonstrates favorable long-term local control and acceptable safety, with LRT as the optimal subtype. It excels in bulky tumors and OAR-adjacent lesions, particularly bone/visceral metastases, providing robust evidence for its prioritized clinical application.
- 27 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessSFRT vs CRT/SBRT: A Clinical Trials Simulated (CTS) Study on Short-Term Objective Response Rate, Long-Term Local Control Rate, and Efficacy Gain Prediction for Bulky Tumors
Background: Spatially Fractionated Radiation Therapy (SFRT) is a promising modality for bulky tumors (≥5 cm) and lesions adjacent to critical organs-at-risk (OARs), but existing evidence lacks systematic evaluation of its long-term efficacy, subtype heterogeneity, and priority indications.Purpose: This clinical trial simulation (CTS) integrates meta-analysis, the Linear- Quadratic (LQ) model, and Weibull survival model to exclusively assess SFRT’s therapeutic profile, addressing core evidence gaps of SFRT-focused research.Materials and Methods: A SFRT-centric analytical framework was established: (1) Meta-analysis of 19 eligible studies (17 high-quality, 2 moderate-quality) covering 5 SFRT subtypes (LRT, GRID, proton SFGRT, 3D-SFRT, SBRT-PATHY); (2) Subgroup analyses by SFRT subtype, tumor site (bone metastases, visceral metastases, primary tumors), and tumor size (bulky ≥5 cm vs non-bulky <5 cm); (3) Mathematical modeling (LQ model for BED-3-year LCR correlation; Weibull model for long-term OS extrapolation) to fill data gaps. Sensitivity analyses (radiobiological parameter adjustment, alternative statistical models) verified robustness.Results: SFRT exhibited robust long-term efficacy: The LQ model (R²=0.98) confirmed a strong BED-LCR correlation, with a median BED of 78.4 Gy (65.2–95.5 Gy) predicting a 3-year LCR of 77.9% (95%CI:71.5–84.3%). Among subtypes, LRT achieved the highest 3-year LCR (81.3% [95%CI:74.5–88.1%]) and lowest Grade 3+ toxicity (8.5%), followed by proton SFGRT (72.5%, 12.3%) and GRID (68.7%, 15.7%). SFRT showed prominent benefits in bone metastases (3-month pain relief rate=70.0%), visceral metastases (3-year LCR=78.5% [95%CI:69.8–87.2%], 0% OAR dose violation), and bulky tumors (3-year LCR=74.3% [95%CI:66.8–81.8%]). Weibull extrapolation revealed SFRT’s survival profile in advanced lesions: 3-year OS of 27.9% (95%CI:6.1–49.7%) for advanced bulky cervical cancer and 12.9% (95%CI:7.4–18.4%) for bone metastases. Pooled Grade 3+ toxicity of SFRT was 10.2% (95%CI:6.8–15.4%) with no Grade 4–5 toxicity, dominated by mild fatigue and dermatitis.Conclusions: SFRT demonstrates favorable long-term local control and acceptable safety, with LRT as the optimal subtype. It excels in bulky tumors and OAR-adjacent lesions, particularly bone/visceral metastases, providing robust evidence for its prioritized clinical application.
- Open Access
- 19 January 2026
- Published by Wiley in Precision Radiation Oncology
- Vol. 10 (1) , 77-87
A novel method for generating a fused ventilation–perfusion map using CT‐derived ventilation and FDG‐PET for lung functional avoidance in radiotherapy: A feasibility study
Background: Pulmonary ventilation–perfusion function plays a crucial role in both radiotherapy planning and prognosis assessment in patients with lung cancer. However, there remains a lack of rapid and cost‐effective imaging modalities capable of accurately capturing this functional parameter. Purpose: This study aimed to develop a lung functional image that reflects ventilation–perfusion characteristics by integrating computed tomography (CT) and (positron emission tomography) PET imaging techniques, with the objective of enhancing lung dose evaluation in radiotherapy planning. Approach: A retrospective analysis was performed on twenty lung cancer patients using CT images acquired at two respiratory phases and FDG‐PET/CT images. The Elastic Distortion algorithm was applied for deformable image registration, with the end‐expiration phase CT serving as the baseline. Values derived from the determinant Jacobian matrices of ventilation CT (V‐CT) images and the gray‐value matrices of PET images were normalized to a range of 0 to 1. These normalized values were multiplied to generate a ventilation–perfusion matrix. Three types of lung functional images were produced from these matrices: ventilation‐imaging (V‐imaging), perfusion‐imaging (P‐imaging), and ventilation–perfusion‐ imaging (VP‐imaging). The Dice Similarity Coefficient (DSC) and Bland–Altman plots were used to assess the correlations and discrepancies among the imaging modalities. Results: The DSC values for the entire lung, regions with low 30% functionality, and regions with high 40% functionality were 0.39 ± 0.05, 0.50 ± 0.03, and 0.20 ± 0.05 for V–P; 0.58 ± 0.03, 0.73 ± 0.03, and 0.32 ± 0.02 for V–VP; and 0.68 ± 0.04, 0.78 ± 0.04, and 0.34 ± 0.04 for P–VP, respectively. Notably, significant concordance was observed between V–VP and P–VP images within the delineated functional lung regions.#x02013;Altman analysis supported the DSC results, revealing high correlation coefficients in the low 30% functional lung region: 0.628 for V–P, 0.857 for V–VP, and 0.779 for P–VP. In contrast, similarity within the high 40% functional regions was markedly lower. Conclusion: This study developed a novel method for generating a fused VP map by integrating CT‐derived ventilation and FDG‐PET data. The method demonstrated feasibility, and the resulting VP map provided a balanced representation of both ventilation and perfusion signals, particularly in regions with reduced lung function.
- 19 January 2026
- Published by Wiley in Precision Radiation Oncology
- Vol. 10 (1) , 77-87
Open AccessA novel method for generating a fused ventilation–perfusion map using CT‐derived ventilation and FDG‐PET for lung functional avoidance in radiotherapy: A feasibility study
Background: Pulmonary ventilation–perfusion function plays a crucial role in both radiotherapy planning and prognosis assessment in patients with lung cancer. However, there remains a lack of rapid and cost‐effective imaging modalities capable of accurately capturing this functional parameter. Purpose: This study aimed to develop a lung functional image that reflects ventilation–perfusion characteristics by integrating computed tomography (CT) and (positron emission tomography) PET imaging techniques, with the objective of enhancing lung dose evaluation in radiotherapy planning. Approach: A retrospective analysis was performed on twenty lung cancer patients using CT images acquired at two respiratory phases and FDG‐PET/CT images. The Elastic Distortion algorithm was applied for deformable image registration, with the end‐expiration phase CT serving as the baseline. Values derived from the determinant Jacobian matrices of ventilation CT (V‐CT) images and the gray‐value matrices of PET images were normalized to a range of 0 to 1. These normalized values were multiplied to generate a ventilation–perfusion matrix. Three types of lung functional images were produced from these matrices: ventilation‐imaging (V‐imaging), perfusion‐imaging (P‐imaging), and ventilation–perfusion‐ imaging (VP‐imaging). The Dice Similarity Coefficient (DSC) and Bland–Altman plots were used to assess the correlations and discrepancies among the imaging modalities. Results: The DSC values for the entire lung, regions with low 30% functionality, and regions with high 40% functionality were 0.39 ± 0.05, 0.50 ± 0.03, and 0.20 ± 0.05 for V–P; 0.58 ± 0.03, 0.73 ± 0.03, and 0.32 ± 0.02 for V–VP; and 0.68 ± 0.04, 0.78 ± 0.04, and 0.34 ± 0.04 for P–VP, respectively. Notably, significant concordance was observed between V–VP and P–VP images within the delineated functional lung regions.#x02013;Altman analysis supported the DSC results, revealing high correlation coefficients in the low 30% functional lung region: 0.628 for V–P, 0.857 for V–VP, and 0.779 for P–VP. In contrast, similarity within the high 40% functional regions was markedly lower. Conclusion: This study developed a novel method for generating a fused VP map by integrating CT‐derived ventilation and FDG‐PET data. The method demonstrated feasibility, and the resulting VP map provided a balanced representation of both ventilation and perfusion signals, particularly in regions with reduced lung function.
- Open Access
- 26 December 2025
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 24
Comparing dose differences of target and cardiac substructures after radiotherapy interruption for left breast cancer: A study of three dose compensatory calculation strategies
Objective: This study aimed to determine the optimal Biological Effective Dose (BED)-based compensation strategy for treatment interruptions in left-sided breast cancer radiotherapy, with a focus on evaluating cardiac substructures to address a previously unmet clinical need. Methods: Twenty patients with left-sided breast cancer who had received radiotherapy were retrospectively enrolled. Simulations assumed treatment interruptions (number of interruption days) occurred after the first week, ranging from 1 to 10 days. Three BED-based compensation strategies were evaluated: (A) maintaining total fractions and days while delivering twice-daily treatments; (B) maintaining total days while increasing the dose per fraction; and (C) keeping the dose per fraction constant while extending the overall treatment course. Original uninterrupted plans served as the baseline. BEDs for the planning target volume (PTV), simultaneous integrated boost (SIB), cardiac substructures and other organs at risk (OARs) were calculated. Physical and BED differences among the schemes were systematically compared. Results: Compared to the original scheme, physical doses to PTV and SIB were lower in Scheme B but higher in Scheme C. As interruptions increased from 1 to 10 days, PTV and SIB doses in Scheme B decreased to minimum values of 42.71 Gy and 50.58 Gy, respectively, while Scheme C resulted in maximum values of 58.60 Gy and 67.15 Gy. Analysis of BED changes (ΔBED) in OARs revealed that the left anterior descending artery (LAD) was the most affected cardiac substructure, with ΔBED values of 0.41, –1.20 and 0.60 for Schemes A, B and C, respectively, at 10 interruption days. Among other OARs, the left lung showed the highest ΔBED changes (0.39, –0.30 and 0.32, respectively). Most OAR comparisons reached statistical significance (ANOVA, p < 0.05). Conclusion: Compensation strategies for radiotherapy interruptions significantly influence the BED of OARs, particularly in the LAD and left lung. Scheme B most effectively reduced the BED of OARs but requires replanning. Schemes A and C offer clinical convenience at the cost of a higher BED of OARs. The choice of compensation strategy should be individualised based on clinical priorities and patient-specific anatomy.
- 26 December 2025
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 24
Open AccessComparing dose differences of target and cardiac substructures after radiotherapy interruption for left breast cancer: A study of three dose compensatory calculation strategies
Objective: This study aimed to determine the optimal Biological Effective Dose (BED)-based compensation strategy for treatment interruptions in left-sided breast cancer radiotherapy, with a focus on evaluating cardiac substructures to address a previously unmet clinical need. Methods: Twenty patients with left-sided breast cancer who had received radiotherapy were retrospectively enrolled. Simulations assumed treatment interruptions (number of interruption days) occurred after the first week, ranging from 1 to 10 days. Three BED-based compensation strategies were evaluated: (A) maintaining total fractions and days while delivering twice-daily treatments; (B) maintaining total days while increasing the dose per fraction; and (C) keeping the dose per fraction constant while extending the overall treatment course. Original uninterrupted plans served as the baseline. BEDs for the planning target volume (PTV), simultaneous integrated boost (SIB), cardiac substructures and other organs at risk (OARs) were calculated. Physical and BED differences among the schemes were systematically compared. Results: Compared to the original scheme, physical doses to PTV and SIB were lower in Scheme B but higher in Scheme C. As interruptions increased from 1 to 10 days, PTV and SIB doses in Scheme B decreased to minimum values of 42.71 Gy and 50.58 Gy, respectively, while Scheme C resulted in maximum values of 58.60 Gy and 67.15 Gy. Analysis of BED changes (ΔBED) in OARs revealed that the left anterior descending artery (LAD) was the most affected cardiac substructure, with ΔBED values of 0.41, –1.20 and 0.60 for Schemes A, B and C, respectively, at 10 interruption days. Among other OARs, the left lung showed the highest ΔBED changes (0.39, –0.30 and 0.32, respectively). Most OAR comparisons reached statistical significance (ANOVA, p < 0.05). Conclusion: Compensation strategies for radiotherapy interruptions significantly influence the BED of OARs, particularly in the LAD and left lung. Scheme B most effectively reduced the BED of OARs but requires replanning. Schemes A and C offer clinical convenience at the cost of a higher BED of OARs. The choice of compensation strategy should be individualised based on clinical priorities and patient-specific anatomy.
- Open Access
- 23 December 2025
- Published by Wiley in Precision Radiation Oncology
- Vol. 10 (2) , 137-146
Automated quality assurance of HDR brachytherapy: Evaluation of Dwell‐position accuracy and Dwell‐time linearity via image processing of radiochromic films
Purpose: To develop and validate a fully automated quality assurance method for high‐dose rate (HDR) brachytherapy, enabling the precise evaluation of source dwell‐position accuracy and dwell‐time linearity using radiochromic film analysis and advanced image processing algorithms. Methods: A novel analytical framework was established to verify HDR source positional precision and dwell‐time linearity. Radiochromic films were irradiated under predefined treatment plans. Image preprocessing involved grayscale conversion, median filtering, rotation correction, and absolute coordinate calibration. The centroid of each dwell position was determined using two‐dimensional Gaussian fitting. Temporal linearity analysis employed radial grayscale summation within the radii of 250–400 pixels. Linearity was quantified using the coefficient of determination (R 2 ), with R 2 approaching 1 indicating optimal performance. Results: Automated Gaussian fitting achieved sub‐millimeter positional accuracy (maximum error ≤ 0.6 mm), eliminating manual intervention. Rotation correction algorithms effectively mitigated positional errors caused by film misalignment. Comparative analysis with commercial software yielded nearly identical results, validating the reliability of the method. Dwell‐time analysis demonstrated excellent linearity ( R 2 ≥ 0.999) over summation radii ranging from 150 to 400 dpi. Conclusions: This study presents a robust and fully automated quality assurance (QA) solution for HDR brachytherapy that simultaneously verifies sub‐millimeter‐level dwell‐position accuracy and temporal linearity. The integration of radiochromic film dosimetry with algorithmic image processing eliminates manual intervention and standardizes QA workflows, representing a substantial advancement in treatment safety and efficiency.
- 23 December 2025
- Published by Wiley in Precision Radiation Oncology
- Vol. 10 (2) , 137-146
Open AccessAutomated quality assurance of HDR brachytherapy: Evaluation of Dwell‐position accuracy and Dwell‐time linearity via image processing of radiochromic films
Purpose: To develop and validate a fully automated quality assurance method for high‐dose rate (HDR) brachytherapy, enabling the precise evaluation of source dwell‐position accuracy and dwell‐time linearity using radiochromic film analysis and advanced image processing algorithms. Methods: A novel analytical framework was established to verify HDR source positional precision and dwell‐time linearity. Radiochromic films were irradiated under predefined treatment plans. Image preprocessing involved grayscale conversion, median filtering, rotation correction, and absolute coordinate calibration. The centroid of each dwell position was determined using two‐dimensional Gaussian fitting. Temporal linearity analysis employed radial grayscale summation within the radii of 250–400 pixels. Linearity was quantified using the coefficient of determination (R 2 ), with R 2 approaching 1 indicating optimal performance. Results: Automated Gaussian fitting achieved sub‐millimeter positional accuracy (maximum error ≤ 0.6 mm), eliminating manual intervention. Rotation correction algorithms effectively mitigated positional errors caused by film misalignment. Comparative analysis with commercial software yielded nearly identical results, validating the reliability of the method. Dwell‐time analysis demonstrated excellent linearity ( R 2 ≥ 0.999) over summation radii ranging from 150 to 400 dpi. Conclusions: This study presents a robust and fully automated quality assurance (QA) solution for HDR brachytherapy that simultaneously verifies sub‐millimeter‐level dwell‐position accuracy and temporal linearity. The integration of radiochromic film dosimetry with algorithmic image processing eliminates manual intervention and standardizes QA workflows, representing a substantial advancement in treatment safety and efficiency.
- Open Access
- 31 August 2022
- Published by Wiley in Precision Radiation Oncology
- Vol. 6 (3) , 234-242
Dosimetric comparison of AcurosBV with AAPM TG43 dose calculation formalism in cervical intraductal high‐dose‐rate brachytherapy using three different applicators
Purpose: To compare the dosimetric effects of American Association of Physicists in Medicine (AAPM) TG43 dose formalism and AcurosBV (grid‐based Boltzmann solver, GBBS) formalism on high‐dose‐rate (HDR) brachytherapy planning for cervical cancer patients irradiated using three different applicators.Methods: A TG43 plan and a AcurosBV plan were generated for each of the 30 patients. Twenty patients who had undergone whole pelvic radiotherapy followed by cervical HDR brachytherapy and the remaining 10 patients who underwent total hysterectomy only gave HDR brachytherapy also were enrolled in this study. The patients were divided into three groups according to the types of applicators used: tandem and ovoid (T&O), tandem and ring (T&R), and cylinder. To compare the dosimetric parameters, the cumulative dose‐volume histograms (DVHs) were measured. We also compared the doses at 90% of the volume (D90%), the volume receiving 100% and 150% of the prescribed dose (V100% and V150%) for the clinical target volume (CTV‐HR), and the doses of point A, the dose receiving 0.1 and 2 cc of the volume (D0.1cc and D2cc) for the organs‐at‐risk (OARs).Results: Compared with the AcurosBV plans, TG43 plans predicted higher D90%, V100%, and V150% of CTV‐HR, dose of point A, and D0.1cc and D2cc of OARs in three types of applicators. Except D2cc of sigmoid in T&R and cylinder applicators, the D90%, V100%, and V150% of CTV‐HR; the dose of point A and the D0.1cc and D2cc of bladder, rectum, and small bowel exhibited significant discrepancies (all p < 0.05). The effects of the three types of applicators on the dose distribution were quite different due to the differences in the materials: The dose difference of CTV‐HR and OARs was greatest (around 10%) for T&O applicators but only 1–5% for T&R and cylinder applicators.Conclusions: AcurosBV was more accurate in calculating the doses in the air cavity and high‐density substance than TG43. In the clinical setting, AcurosBV exhibited different dosimetric distributions in the cervix plans for HDR brachytherapy, especially in treatment planning when using T&O applicators. The AcurosBV algorithm should be considered when using T&O applicators or other materials with a much higher or lower density (metal or air) than soft tissue. However, If the density is close to that of soft tissue, considering AcurosBV algorithm requires more calculation time, TG43 could still be selected when using applicators in clinical.
- 31 August 2022
- Published by Wiley in Precision Radiation Oncology
- Vol. 6 (3) , 234-242
Open AccessDosimetric comparison of AcurosBV with AAPM TG43 dose calculation formalism in cervical intraductal high‐dose‐rate brachytherapy using three different applicators
Purpose: To compare the dosimetric effects of American Association of Physicists in Medicine (AAPM) TG43 dose formalism and AcurosBV (grid‐based Boltzmann solver, GBBS) formalism on high‐dose‐rate (HDR) brachytherapy planning for cervical cancer patients irradiated using three different applicators.Methods: A TG43 plan and a AcurosBV plan were generated for each of the 30 patients. Twenty patients who had undergone whole pelvic radiotherapy followed by cervical HDR brachytherapy and the remaining 10 patients who underwent total hysterectomy only gave HDR brachytherapy also were enrolled in this study. The patients were divided into three groups according to the types of applicators used: tandem and ovoid (T&O), tandem and ring (T&R), and cylinder. To compare the dosimetric parameters, the cumulative dose‐volume histograms (DVHs) were measured. We also compared the doses at 90% of the volume (D90%), the volume receiving 100% and 150% of the prescribed dose (V100% and V150%) for the clinical target volume (CTV‐HR), and the doses of point A, the dose receiving 0.1 and 2 cc of the volume (D0.1cc and D2cc) for the organs‐at‐risk (OARs).Results: Compared with the AcurosBV plans, TG43 plans predicted higher D90%, V100%, and V150% of CTV‐HR, dose of point A, and D0.1cc and D2cc of OARs in three types of applicators. Except D2cc of sigmoid in T&R and cylinder applicators, the D90%, V100%, and V150% of CTV‐HR; the dose of point A and the D0.1cc and D2cc of bladder, rectum, and small bowel exhibited significant discrepancies (all p < 0.05). The effects of the three types of applicators on the dose distribution were quite different due to the differences in the materials: The dose difference of CTV‐HR and OARs was greatest (around 10%) for T&O applicators but only 1–5% for T&R and cylinder applicators.Conclusions: AcurosBV was more accurate in calculating the doses in the air cavity and high‐density substance than TG43. In the clinical setting, AcurosBV exhibited different dosimetric distributions in the cervix plans for HDR brachytherapy, especially in treatment planning when using T&O applicators. The AcurosBV algorithm should be considered when using T&O applicators or other materials with a much higher or lower density (metal or air) than soft tissue. However, If the density is close to that of soft tissue, considering AcurosBV algorithm requires more calculation time, TG43 could still be selected when using applicators in clinical.
- Open Access
- 22 July 2021
- Published by Springer Nature in Research Square
Dosimetric Comparison of IMRT, Hybrid IMRT and Hybrid VMAT For Early Stage Right-Sided Breast Cancer
Purpose This study aimed to evaluate the clinical impact of hybrid intensity-modulated radiotherapy (IMRT) and hybrid volumetric-modulated arc therapy (VMAT) for early-stage breast cancer, including plan quality and second cancer risk (SCR). Methods Three different plans were designed in full IMRT, hybrid IMRT, and hybrid VMAT for each of eight patients with early-stage breast cancer. Target quality, organs at risk (OARs) sparing, and SCR were compared among the three plans. Results Compared with the hybrid IMRT, full IMRT showed deterioration in terms of D2% of simultaneous integrated boost (SIB), V10 of ipsilateral lung, and excess absolute risk (EAR) to contralateral lung and esophagus. The homogeneity index (HI) of SIB, V5 of ipsilateral lung and combined lung, the Dmax and Dmean of the esophagus, the EAR to contralateral breast and lung, and the EAR to the esophagus with hybrid VMAT dramatically increased by 12.5%, 19.49%, 18.87%, 90.59%, 167.69%, 50.14%, 264.68%, and 160.95%, respectively (p = 0.022; 0.040; 0.044; 0.041; 0.003; 0.020; 0.000; 0.003). The EAR to contralateral breast and contralateral lung by full IMRT was significantly decreased compared with the hybrid VMAT (26.97%, p = 0.033; 50.01%, p = 0.026). Conclusion The results confirmed that hybrid IMRT could achieve better target quality and OARs sparing than full IMRT and hybrid VMAT for early-stage right breast cancer. Hybrid IMRT was the best treatment option, while hybrid VMAT performed the worst among the three plans in terms of SCR to peripheral OARs.
- 22 July 2021
- Published by Springer Nature in Research Square
Open AccessDosimetric Comparison of IMRT, Hybrid IMRT and Hybrid VMAT For Early Stage Right-Sided Breast Cancer
Purpose This study aimed to evaluate the clinical impact of hybrid intensity-modulated radiotherapy (IMRT) and hybrid volumetric-modulated arc therapy (VMAT) for early-stage breast cancer, including plan quality and second cancer risk (SCR). Methods Three different plans were designed in full IMRT, hybrid IMRT, and hybrid VMAT for each of eight patients with early-stage breast cancer. Target quality, organs at risk (OARs) sparing, and SCR were compared among the three plans. Results Compared with the hybrid IMRT, full IMRT showed deterioration in terms of D2% of simultaneous integrated boost (SIB), V10 of ipsilateral lung, and excess absolute risk (EAR) to contralateral lung and esophagus. The homogeneity index (HI) of SIB, V5 of ipsilateral lung and combined lung, the Dmax and Dmean of the esophagus, the EAR to contralateral breast and lung, and the EAR to the esophagus with hybrid VMAT dramatically increased by 12.5%, 19.49%, 18.87%, 90.59%, 167.69%, 50.14%, 264.68%, and 160.95%, respectively (p = 0.022; 0.040; 0.044; 0.041; 0.003; 0.020; 0.000; 0.003). The EAR to contralateral breast and contralateral lung by full IMRT was significantly decreased compared with the hybrid VMAT (26.97%, p = 0.033; 50.01%, p = 0.026). Conclusion The results confirmed that hybrid IMRT could achieve better target quality and OARs sparing than full IMRT and hybrid VMAT for early-stage right breast cancer. Hybrid IMRT was the best treatment option, while hybrid VMAT performed the worst among the three plans in terms of SCR to peripheral OARs.
- Open Access
- 7 May 2021
- Published by Wiley in Precision Radiation Oncology
- Vol. 5 (2) , 93-99
Effects of peripherally inserted central catheter on dosimetry of the blood vessel region in volumetric modulated arc therapy planning for lung cancer
- 7 May 2021
- Published by Wiley in Precision Radiation Oncology
- Vol. 5 (2) , 93-99
Open AccessEffects of peripherally inserted central catheter on dosimetry of the blood vessel region in volumetric modulated arc therapy planning for lung cancer
- Open Access
- 30 October 2020
- Published by Wiley in Precision Radiation Oncology
- Vol. 4 (4) , 106-112