A novel method of emittance matching to increase beam transmission for cyclotron-based proton therapy facilities: simulation study
Open Access
- 1 January 2023
- conference paper
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2420 (1) , 012107
Abstract
In proton therapy, high dose rates can reduce treatment delivery times, allowing for efficient mitigation of tumor motion and increased patient throughput. With cyclotrons however, high dose rates are difficult to achieve for low-energies as, typically, the emittance after the degrader is matched in both transversal planes using circular collimators, which does not provide an optimal matching to the acceptance of the following beamline. Transmission can however be substantially improved by transporting maximum acceptable emittances in both orthogonal planes, but at the cost of gantry angle-dependent beam shapes at isocenter. Here we demonstrate that equal emittances in both planes can be recovered at the gantry entrance using a thin scattering foil, thus ensuring gantry angle-independent beam shapes at the isocenter. We demonstrate in simulation that low-energy beam transmission can be increased by a factor of 3 using this approach compared to the currently used beam optics, whilst gantry angle-independent beam shapes are preserved. We expect that this universal approach could also bring a similar transmission improvement in other cyclotron-based proton therapy facilities.Keywords
This publication has 10 references indexed in Scilit:
- Ultra-fast pencil beam scanning proton therapy for locally advanced non-small-cell lung cancers: Field delivery within a single breath-holdRadiotherapy and Oncology, 2022
- A new emittance selection system to maximize beam transmission for low‐energy beams in cyclotron‐based proton therapy facilities with gantryMedical Physics, 2021
- PO-1762 Feasibility study to achieve hypofractionated IMPT PBS within a single breath-hold for lung cancerRadiotherapy and Oncology, 2021
- The impact of pencil beam scanning techniques on the effectiveness and efficiency of rescanning moving targetsPhysics in Medicine & Biology, 2018
- Robustness of the Voluntary Breath-Hold Approach for the Treatment of Peripheral Lung Tumors Using Hypofractionated Pencil Beam Scanning Proton TherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2016
- The effectiveness of combined gating and re-scanning for treating mobile targets with proton spot scanning. An experimental and simulation-based investigationPhysics in Medicine & Biology, 2014
- More than 10 years experience of beam monitoring with the Gantry 1 spot scanning proton therapy facility at PSIMedical Physics, 2009
- Compensation of the asymmetric phase–space distribution for a slowly extracted beam from a synchrotronNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2006
- The 200‐MeV proton therapy project at the Paul Scherrer Institute: Conceptual design and practical realizationMedical Physics, 1995
- New Gantry Beam Optics Solution for Minimising Treatment Time in Cyclotron-based Proton Therapy Facilities