David Meer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
David Meer has a total of 398 co-authors. Here are the top co-authors by number of shared publications:
- Serena Psoroulas
Department of Radiation Oncology, University Hospital Zurich and University of Zurich, Zurich, Switzerland
5 shared publications - Antony John Lomax
Paul Scherrer Institute, Villigen, Switzerland
3 shared publications - Eric R. Weeks
Emory University
3 shared publications - Vivek Maradia
Department of Radiation Oncology Stanford University School of Medicine Stanford California USA
3 shared publications A. Astvatsatourov
DESY, Zeuthen, Germany
2 shared publicationsA. Belousov
Lebedev Physical Institute, Moscow, Russia
2 shared publications
Latest Publications
- Open Access
- 10 March 2026
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 22 (15) , 2809-2822
Droplet breakup against an isolated obstacle
We describe combined experiments and simulations of droplet breakup during flow-driven interactions with a circular obstacle in a quasi-two-dimensional microfluidic chamber. Due to a lack of in-plane confinement, the droplets can also slip past the obstacle without breaking. Droplets are more likely to break when they have a higher flow velocity, larger size (relative to the obstacle radius R), smaller surface tension, and for head-on collisions with the obstacle. We also observe that droplet-obstacle collisions are more likely to result in breakup when the height of the sample chamber is increased. We define a nondimensional breakup number Bk ∼ Ca, where Ca is the Capillary number, that accounts for changes in the likelihood of droplet break up with variations in these parameters. As Bk increases, we find in both experiments and discrete element method (DEM) simulations of the deformable particle model that the behavior changes from droplets never breaking (Bk ≪ 1) to always breaking for Bk ≫ 1, with a rapid change in the probability of droplet breakup near Bk = 1. We also find that Bk ∼ S4/3, where S characterizes the symmetry of the collision, which implies that the minimum symmetry required for breakup is controlled by a characteristic distance h ∼ R.
- 10 March 2026
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 22 (15) , 2809-2822
Open AccessDroplet breakup against an isolated obstacle
We describe combined experiments and simulations of droplet breakup during flow-driven interactions with a circular obstacle in a quasi-two-dimensional microfluidic chamber. Due to a lack of in-plane confinement, the droplets can also slip past the obstacle without breaking. Droplets are more likely to break when they have a higher flow velocity, larger size (relative to the obstacle radius R), smaller surface tension, and for head-on collisions with the obstacle. We also observe that droplet-obstacle collisions are more likely to result in breakup when the height of the sample chamber is increased. We define a nondimensional breakup number Bk ∼ Ca, where Ca is the Capillary number, that accounts for changes in the likelihood of droplet break up with variations in these parameters. As Bk increases, we find in both experiments and discrete element method (DEM) simulations of the deformable particle model that the behavior changes from droplets never breaking (Bk ≪ 1) to always breaking for Bk ≫ 1, with a rapid change in the probability of droplet breakup near Bk = 1. We also find that Bk ∼ S4/3, where S characterizes the symmetry of the collision, which implies that the minimum symmetry required for breakup is controlled by a characteristic distance h ∼ R.
- 17 June 2024
- Published by American Physical Society (APS) in Physical Review E
- Vol. 109 (6) , 064905
Estimating random close packing density from circle radius distributions
Circles of a single size can pack together densely in a hexagonal lattice, but adding in size variety disrupts the order of those packings. We conduct simulations which generate dense random packings of circles with specified size distributions and measure the area fraction in each case. While the size distributions can be arbitrary, we find that for a wide range of size distributions the random close-packing area fraction under this general protocol is determined to high accuracy by the polydispersity and skewness of the size distribution. At low skewness, all packings tend to a minimum packing fraction independent of polydispersity. In the limit of high skewness, becomes independent of skewness, asymptoting to a polydispersity-dependent limit. We show how these results can be predicted from the behavior of bidisperse or bi-Gaussian circle size distributions.- 17 June 2024
- Published by American Physical Society (APS) in Physical Review E
- Vol. 109 (6) , 064905
Estimating random close packing density from circle radius distributions
Circles of a single size can pack together densely in a hexagonal lattice, but adding in size variety disrupts the order of those packings. We conduct simulations which generate dense random packings of circles with specified size distributions and measure the area fraction in each case. While the size distributions can be arbitrary, we find that for a wide range of size distributions the random close-packing area fraction under this general protocol is determined to high accuracy by the polydispersity and skewness of the size distribution. At low skewness, all packings tend to a minimum packing fraction independent of polydispersity. In the limit of high skewness, becomes independent of skewness, asymptoting to a polydispersity-dependent limit. We show how these results can be predicted from the behavior of bidisperse or bi-Gaussian circle size distributions.- Open Access
Circle radius distributions determine random close packing density
Circles of a single size can pack together densely in a hexagonal lattice, but adding in size variety disrupts the order of those packings. We conduct simulations which generate dense random packings of circles with specified size distributions, and measure the area fraction in each case. While the size distributions can be arbitrary, we find that for a wide range of size distributions the random close packing area fraction $φ_{rcp}$ is determined to high accuracy by the polydispersity and skewness of the size distribution. At low skewness, all packings tend to a minimum packing fraction $φ_0 \approx 0.840$ independent of polydispersity. In the limit of high skewness, $φ_{rcp}$ becomes independent of skewness, asymptoting to a polydispersity-dependent limit. We show how these results can be predicted from the behavior of simple, bidisperse or bi-Gaussian circle size distributions.Open AccessCircle radius distributions determine random close packing density
Circles of a single size can pack together densely in a hexagonal lattice, but adding in size variety disrupts the order of those packings. We conduct simulations which generate dense random packings of circles with specified size distributions, and measure the area fraction in each case. While the size distributions can be arbitrary, we find that for a wide range of size distributions the random close packing area fraction $φ_{rcp}$ is determined to high accuracy by the polydispersity and skewness of the size distribution. At low skewness, all packings tend to a minimum packing fraction $φ_0 \approx 0.840$ independent of polydispersity. In the limit of high skewness, $φ_{rcp}$ becomes independent of skewness, asymptoting to a polydispersity-dependent limit. We show how these results can be predicted from the behavior of simple, bidisperse or bi-Gaussian circle size distributions. - Open Access
- 9 February 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (2) , e0297862
Bounded distributions place limits on skewness and larger moments
Distributions of strictly positive numbers are common and can be characterized by standard statistical measures such as mean, standard deviation, and skewness. We demonstrate that for these distributions the skewnessD3is bounded from below by a function of the coefficient of variation (CoV)δasD3>δ− 1/δ. The results are extended to any distribution that is bounded with minimum valuexminand/or bounded with maximum valuexmax. We build on the results to provide bounds for kurtosisD4, and conjecture analogous bounds exists for higher statistical moments.
- 9 February 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (2) , e0297862
Open AccessBounded distributions place limits on skewness and larger moments
Distributions of strictly positive numbers are common and can be characterized by standard statistical measures such as mean, standard deviation, and skewness. We demonstrate that for these distributions the skewnessD3is bounded from below by a function of the coefficient of variation (CoV)δasD3>δ− 1/δ. The results are extended to any distribution that is bounded with minimum valuexminand/or bounded with maximum valuexmax. We build on the results to provide bounds for kurtosisD4, and conjecture analogous bounds exists for higher statistical moments.
- Open Access
Bounded Distributions place Limits on Skewness and Larger Moments
Distributions of strictly positive numbers are common and can be characterized by standard statistical measures such as mean, standard deviation, and skewness. We demonstrate that for these distributions the skewness $D_3$ is bounded from below by a function of the coefficient of variation (CoV) $δ$ as $D_3 \ge δ-1/δ$. The results are extended to any distribution that is bounded with minimum value $x_{\rm min}$ and/or bounded with maximum value $x_{\rm max}$. We build on the results to provide bounds for kurtosis $D_4$, and conjecture analogous bounds exists for higher statistical moments.Open AccessBounded Distributions place Limits on Skewness and Larger Moments
Distributions of strictly positive numbers are common and can be characterized by standard statistical measures such as mean, standard deviation, and skewness. We demonstrate that for these distributions the skewness $D_3$ is bounded from below by a function of the coefficient of variation (CoV) $δ$ as $D_3 \ge δ-1/δ$. The results are extended to any distribution that is bounded with minimum value $x_{\rm min}$ and/or bounded with maximum value $x_{\rm max}$. We build on the results to provide bounds for kurtosis $D_4$, and conjecture analogous bounds exists for higher statistical moments. - Open Access
- 1 January 2023
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2420 (1) , 012106
A novel intensity compensation method to achieve energy independent beam intensity at the patient location for cyclotron based proton therapy facilities
In cyclotron-based proton therapy facilities, an energy selection system is typically used to lower the beam energy from the fixed value provided by the accelerator (250/230 MeV) to the one needed for the treatment (230-70 MeV). Such a system has the drawback of increase beam emittance and introducing an energy-dependent beam current at the patient location, resulting in energy dependent beam intensity ratios of about 103 between high and low energies. This complicates treatment delivery and challenges patient safety systems. As such, we propose the use of a dual energy degrader method that can reduce beam intensity for high-energy beams. The first degrader is made of high Z material and the second is made of low Z material and are placed next to each other. For high energies (190-230 MeV), we use only the first degrader to increase beam emittance after the degrader and thus lose intensity in the emittance selection collimators. For intermediate energy beams (110-190 MeV) we use the combination of both degraders, whereas for low energy beams (70-110 MeV), only the second degrader limits the increase in emittance. With this approach, energy-independent beam intensities at the patient location can be achieved, whilst localizing beam losses around the degrader.
- 1 January 2023
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2420 (1) , 012106
Open AccessA novel intensity compensation method to achieve energy independent beam intensity at the patient location for cyclotron based proton therapy facilities
In cyclotron-based proton therapy facilities, an energy selection system is typically used to lower the beam energy from the fixed value provided by the accelerator (250/230 MeV) to the one needed for the treatment (230-70 MeV). Such a system has the drawback of increase beam emittance and introducing an energy-dependent beam current at the patient location, resulting in energy dependent beam intensity ratios of about 103 between high and low energies. This complicates treatment delivery and challenges patient safety systems. As such, we propose the use of a dual energy degrader method that can reduce beam intensity for high-energy beams. The first degrader is made of high Z material and the second is made of low Z material and are placed next to each other. For high energies (190-230 MeV), we use only the first degrader to increase beam emittance after the degrader and thus lose intensity in the emittance selection collimators. For intermediate energy beams (110-190 MeV) we use the combination of both degraders, whereas for low energy beams (70-110 MeV), only the second degrader limits the increase in emittance. With this approach, energy-independent beam intensities at the patient location can be achieved, whilst localizing beam losses around the degrader.
- Open Access
- 1 January 2023
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2420 (1) , 012107
A novel method of emittance matching to increase beam transmission for cyclotron-based proton therapy facilities: simulation study
In proton therapy, high dose rates can reduce treatment delivery times, allowing for efficient mitigation of tumor motion and increased patient throughput. With cyclotrons however, high dose rates are difficult to achieve for low-energies as, typically, the emittance after the degrader is matched in both transversal planes using circular collimators, which does not provide an optimal matching to the acceptance of the following beamline. Transmission can however be substantially improved by transporting maximum acceptable emittances in both orthogonal planes, but at the cost of gantry angle-dependent beam shapes at isocenter. Here we demonstrate that equal emittances in both planes can be recovered at the gantry entrance using a thin scattering foil, thus ensuring gantry angle-independent beam shapes at the isocenter. We demonstrate in simulation that low-energy beam transmission can be increased by a factor of 3 using this approach compared to the currently used beam optics, whilst gantry angle-independent beam shapes are preserved. We expect that this universal approach could also bring a similar transmission improvement in other cyclotron-based proton therapy facilities.
- 1 January 2023
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2420 (1) , 012107
Open AccessA novel method of emittance matching to increase beam transmission for cyclotron-based proton therapy facilities: simulation study
In proton therapy, high dose rates can reduce treatment delivery times, allowing for efficient mitigation of tumor motion and increased patient throughput. With cyclotrons however, high dose rates are difficult to achieve for low-energies as, typically, the emittance after the degrader is matched in both transversal planes using circular collimators, which does not provide an optimal matching to the acceptance of the following beamline. Transmission can however be substantially improved by transporting maximum acceptable emittances in both orthogonal planes, but at the cost of gantry angle-dependent beam shapes at isocenter. Here we demonstrate that equal emittances in both planes can be recovered at the gantry entrance using a thin scattering foil, thus ensuring gantry angle-independent beam shapes at the isocenter. We demonstrate in simulation that low-energy beam transmission can be increased by a factor of 3 using this approach compared to the currently used beam optics, whilst gantry angle-independent beam shapes are preserved. We expect that this universal approach could also bring a similar transmission improvement in other cyclotron-based proton therapy facilities.
- Open Access
Universal and dynamic ridge filter for pencil beam scanning particle therapy: novel concept for ultra-fast treatment delivery
Purpose In PBS particle therapy, short treatment delivery time is paramount for the efficient treatment of moving targets with motion mitigation techniques (such as breath-hold, rescanning, and gating). Energy and spot position change time are limiting factors in reducing treatment time. In this study, we designed a universal and dynamic energy modulator (ridge filter, RF) to broaden the Bragg peak, to reduce the number of energies and spots required to cover the target volume, thus lowering the treatment time. Methods Our RF unit comprises two identical RFs placed just before the isocenter. Both RFs move relative to each other, changing the Bragg peaks characteristics dynamically. We simulated different Bragg peak shapes with the RF in TOPAS and validated them experimentally. We then delivered single-field plans with 1Gy/fraction to different geometrical targets in water, to measure the dose delivery time using the RF and compare it with the clinical settings. Results Aligning the RFs in different positions produces different broadening in the Bragg peak; we achieved a maximum broadening of 2 cm. With RF we reduced the number of energies in a field by more than 60%, and the dose delivery time by 50%, for all geometrical targets investigated, without compromising the dose distribution transverse and distal fall-off. Conclusions Our novel universal and dynamic RF allows for the adaptation of the Bragg peak broadening for a spot and/or energy layer based on the requirement of dose shaping in the target volume. It significantly reduces the number of energy layers and spots to cover the target volume, and thus the treatment time. This RF design is ideal for ultra-fast treatment delivery within a single breath-hold (5-10 sec), efficient delivery of motion mitigation techniques, and small animal irradiation with ultra-high dose rates (FLASH).
Open AccessUniversal and dynamic ridge filter for pencil beam scanning particle therapy: novel concept for ultra-fast treatment delivery
Purpose In PBS particle therapy, short treatment delivery time is paramount for the efficient treatment of moving targets with motion mitigation techniques (such as breath-hold, rescanning, and gating). Energy and spot position change time are limiting factors in reducing treatment time. In this study, we designed a universal and dynamic energy modulator (ridge filter, RF) to broaden the Bragg peak, to reduce the number of energies and spots required to cover the target volume, thus lowering the treatment time. Methods Our RF unit comprises two identical RFs placed just before the isocenter. Both RFs move relative to each other, changing the Bragg peaks characteristics dynamically. We simulated different Bragg peak shapes with the RF in TOPAS and validated them experimentally. We then delivered single-field plans with 1Gy/fraction to different geometrical targets in water, to measure the dose delivery time using the RF and compare it with the clinical settings. Results Aligning the RFs in different positions produces different broadening in the Bragg peak; we achieved a maximum broadening of 2 cm. With RF we reduced the number of energies in a field by more than 60%, and the dose delivery time by 50%, for all geometrical targets investigated, without compromising the dose distribution transverse and distal fall-off. Conclusions Our novel universal and dynamic RF allows for the adaptation of the Bragg peak broadening for a spot and/or energy layer based on the requirement of dose shaping in the target volume. It significantly reduces the number of energy layers and spots to cover the target volume, and thus the treatment time. This RF design is ideal for ultra-fast treatment delivery within a single breath-hold (5-10 sec), efficient delivery of motion mitigation techniques, and small animal irradiation with ultra-high dose rates (FLASH).
- 25 February 2022
- Published by Elsevier in Physica Medica
- Vol. 94, S33
FLASH in the Clinic Track (Oral Presentations) OPTICALLY STIMULATED LUMINESCENCE DETECTORS (OSLDS) FOR ULTRA-HIGH DOSE RATE PROTON DOSIMETRY
- 25 February 2022
- Published by Elsevier in Physica Medica
- Vol. 94, S33
FLASH in the Clinic Track (Oral Presentations) OPTICALLY STIMULATED LUMINESCENCE DETECTORS (OSLDS) FOR ULTRA-HIGH DOSE RATE PROTON DOSIMETRY
- 25 February 2022
- Published by Elsevier in Physica Medica
- Vol. 94, S33-S34
FLASH in the Clinic Track (Oral Presentations) ULTRA-HIGH DOSE RATE DOSIMETRY FOR PRE-CLINICAL EXPERIMENTS WITH MM-SMALL PROTON FIELDS
- 25 February 2022
- Published by Elsevier in Physica Medica
- Vol. 94, S33-S34
FLASH in the Clinic Track (Oral Presentations) ULTRA-HIGH DOSE RATE DOSIMETRY FOR PRE-CLINICAL EXPERIMENTS WITH MM-SMALL PROTON FIELDS