Background and Objective Posterior capsular opacification (PCO) is the most frequent complication after cataract surgery. The most used method in order to disrupt the opacified posterior capsule is Nd‐YAG laser posterior capsulotomy. Our aim was to evaluate the impact of Nd‐YAG laser posterior capsulotomy on ocular pulse amplitude (OPA), central corneal thickness (CCT), corneal volume (CV), iridocorneal angle (ICA), and anterior chamber depth (ACD). Materials and Methods Thirty‐three eyes of 30 pseudophakic patients who underwent Nd‐YAG capsulotomy due to posterior capsule opacification, were included in this prospective cross‐sectional consecutive case series. The OPA was measured with the Pascal dynamic contour tonometer. The CCT, CV, ICA, and ACD measurements were taken with the Scheimpflug imaging system (Pentacam HR). The examinations were performed preoperatively, and repeated at the postoperative first hour, week, and month. Results The mean OPA, ICA, and ACD values did not change statistically significantly after the posterior capsulotomy (P > 0.05). The mean CCT increased markedly and the mean CV increased slightly after one hour from the capsulotomy (P = 0.001 and P = 0.02, respectively), and then returned to the baseline values at the first week and first month visits (P > 0.05). Conclusions Nd:YAG capsulotomy does not significantly alter OPA, ICA, and ACD; but it causes temporary increase of CCT and CV in the short term. Lasers Surg. Med. 46:553–557, 2014.Keywords
This publication has 26 references indexed in Scilit:
- THE STUDY OF COMPLICATIONS OF ND: YAG LASER CAPSULOTOMYInternational Journal of Bioinformatics Research, 2012
- Relationship between ocular pulse amplitude and systemic blood pressure measurementsActa Ophthalmologica, 2009
- Dynamic contour tonometry: principle and useClinical & Experimental Ophthalmology, 2006
- Intraocular pressure and ocular pulse amplitude using dynamic contour tonometry and contact lens tonometryBMC Ophthalmology, 2004
- Episodic acute hypotonia after Nd:YAG laser capsulotomy—retinal function and choroidal swellingVision Research, 1997
- Posterior capsule opacificationSurvey of Ophthalmology, 1992
- Ciliochoroidal effusions after neodymium:YAG posterior capsulotomy: Association with pre-existing glaucoma and uveitisJournal of Cataract & Refractive Surgery, 1989
- Long-term results of Nd:YAG laser posterior capsulotomy with the Swiss laserJournal of Cataract & Refractive Surgery, 1986
- Long-term follow-up of Nd:YAG laser posterior capsulotomyAmerican Intra-Ocular Implant Society Journal, 1984
- Posterior Capsule Opacification in Pseudophakic EyesOphthalmology, 1983