External Ventricular Drain Placement Using Active Augmented Reality Guidance: A Proof of Concept of a Clinically Integrable System
- 10 July 2025
- journal article
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 30 (3) , 414-421
Abstract
BACKGROUND AND OBJECTIVES: Suboptimal placement occurs in 26% of external ventricular drain (EVD) procedures performed using traditional freehand methods. We developed a low-cost augmented reality stereotactic navigation system aimed at improving accuracy and safety of the procedure, which is readily compatible with existing Picture Archiving and Communication Systems and automated image segmentation algorithms. METHODS: The system integrates cloud storage, image segmentation, trajectory planning, point-based image-to-patient registration, and real-time 3-dimensional guidance superimposed over the surgical field. As a proof of concept, 15 neurosurgeons, neurosurgical residents, and physician assistants used anatomical landmark–based registration to conduct 29 EVD placements on anatomical phantoms with small ventricles within a simulated surgical environment. From postoperative computed tomography, placement accuracy was assessed using the Kakarla grading scale, along with the distance to target and angular deviation. RESULTS: Twenty EVDs (69.0%; 95% CI, 52.1%-85.8%) were graded as optimal Kakarla 1 placements, 4 (13.8%; 95% CI, 1.2%-26.3%) as suboptimal Kakarla 2 placements, and 5 (17.2%; 95% CI, 3.5%-31.0%) as suboptimal Kakarla 3 placements. The mean distance to target was 9.49 mm (SD, 4.64 mm), and the mean angular deviation was 9.20° (SD, 6.35°). The mean workflow time was 22 minutes 45 seconds (SD, 11 minutes 38 seconds), and the system demonstrated a fiducial registration error of 4.00 mm (SD, 1.16 mm). Challenges related to human-computer interaction were identified, suggesting further refinement is needed to optimize usability. CONCLUSION: While the accuracy, user interface, and procedural time of the system require further refinement for clinical implementation, this proof of concept demonstrates the clinical and technical feasibility of an end-to-end 3-dimensional augmented reality system with the potential to enhance the safety and accuracy of EVD placements.Keywords
Funding Information
- HORIZON EUROPE Framework Programme (190106553)
This publication has 28 references indexed in Scilit:
- Development and Validation of a Neurosurgical Phantom for Simulating External Ventricular Drain PlacementJournal of Medical Systems, 2025
- NnU-Net versus mesh growing algorithm as a tool for the robust and timely segmentation of neurosurgical 3D images in contrast-enhanced T1 MRI scansActa Neurochirurgica, 2024
- Nail it! vision-based drift correction for accurate mixed reality surgical guidanceInternational Journal of Computer Assisted Radiology and Surgery, 2023
- Systematic review and meta-analysis of external ventricular drain placement accuracy and narrative review of guidance devicesJournal of Clinical Neuroscience, 2021
- Holographic patient tracking after bed movement for augmented reality neuronavigation using a head-mounted displayActa Neurochirurgica, 2021
- Accuracy and complication rates of external ventricular drain placement with twist drill and bolt system versus standard trephine and tunnelation: a retrospective population-based studyActa Neurochirurgica, 2020
- Inattention blindness in surgerySurgical Endoscopy, 2015
- Ventriculostomy: Frequency, length of stay and in-hospital mortality in the United States of America, 1988–2010Journal of Clinical Neuroscience, 2014
- 3D Slicer as an image computing platform for the Quantitative Imaging NetworkMagnetic Resonance Imaging, 2012
- A survey of ventriculostomy and intracranial pressure monitor placement practicesSurgical Neurology, 2008