Jesse A. M. van Doormaal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jesse A. M. van Doormaal has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Tristan P. C. van Doormaal
Department of Neurosurgery, University Medical Center Utrecht, Utrecht, The Netherlands
4 shared publications - Eelco Wieger Hoving
Princess Maxima Center for Pediatric Oncology, Utrecht, The Netherlands
3 shared publications - Pierre A. Robe
Department of Neurosurgery, University Medical Center Utrecht, Utrecht, The Netherlands
3 shared publications Bachtiar Burhani
Department of Neurosurgery, St. Elisabeth Hospital, Tilburg, The Netherlands
2 shared publications- Maarten Bot
Department of Neurosurgery, Amsterdam University Medical Center, Amsterdam, The Netherlands
2 shared publications - Tim Fick
Department of Neurosurgery, University Medical Center Utrecht, Utrecht, The Netherlands
2 shared publications
Latest Publications
- Open Access
- 24 December 2025
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 167 (1)
Comparing augmented reality-assisted and freehand external ventricular drain placement: a multicenter randomized controlled crossover phantom study
Background: External ventricular drain (EVD) placement is a common neurosurgical procedure with high rates of misplacement when performed using the freehand technique. With augmented reality (AR), the accuracy of EVD placement could be improved by providing a 3-D overlay, guiding optimal placement using a virtual trajectory superimposed over the patient. In this study, we aimed to assess the efficacy and usability of an AR application for assisting EVD placements which supported trajectory planning, point-based image-to-patient registration and 3-D stereoscopic projection. Method: We conducted a randomized controlled crossover trial involving 15 neurosurgical residents and one neurosurgeon, who performed 236 EVD procedures (118 AR-assisted and 118 freehand) on biomimetic phantoms. EVD placement accuracy was evaluated using the Kakarla scale, distance-to-target, angular inaccuracy, and depth inaccuracy. The total procedural time was recorded. The user experience was evaluated using the NASA Task Load Index (NASA-TLX) and the Usefulness, Satisfaction, and Ease of Use (USE) questionnaire. Results: AR-assisted placement achieved significantly higher rates of optimal placement (Kakarla grade 1: 57.6% vs 37.3%; p < .001), lower rates of erroneous placement (Kakarla grade 3: 21.2% vs 40.7%; p < .001), a lower distance-to-target (median, 7.2 mm vs 11.4 mm; p < .001) and lower angular inaccuracy (median, 5.58° vs 7.60°; p < .001). Procedural time was longer for AR (median, 7 min 30 s vs 1 min 11 s; p < .001). Participants rated the AR system favorably on the USE for ease of learning (mean, 6.09/7 [SD, 0.94]) and satisfaction (mean, 6.45/7 [SD, 0.69]), while NASA-TLX scores indicated similar workloads between AR and freehand techniques. Conclusions: AR improves the accuracy of EVD placement compared to the freehand technique, which is expected to improve the efficacy in clinical settings. It increases total procedural time but remains within clinically acceptable limits and provides favorable usability.
- 24 December 2025
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 167 (1)
Open AccessComparing augmented reality-assisted and freehand external ventricular drain placement: a multicenter randomized controlled crossover phantom study
Background: External ventricular drain (EVD) placement is a common neurosurgical procedure with high rates of misplacement when performed using the freehand technique. With augmented reality (AR), the accuracy of EVD placement could be improved by providing a 3-D overlay, guiding optimal placement using a virtual trajectory superimposed over the patient. In this study, we aimed to assess the efficacy and usability of an AR application for assisting EVD placements which supported trajectory planning, point-based image-to-patient registration and 3-D stereoscopic projection. Method: We conducted a randomized controlled crossover trial involving 15 neurosurgical residents and one neurosurgeon, who performed 236 EVD procedures (118 AR-assisted and 118 freehand) on biomimetic phantoms. EVD placement accuracy was evaluated using the Kakarla scale, distance-to-target, angular inaccuracy, and depth inaccuracy. The total procedural time was recorded. The user experience was evaluated using the NASA Task Load Index (NASA-TLX) and the Usefulness, Satisfaction, and Ease of Use (USE) questionnaire. Results: AR-assisted placement achieved significantly higher rates of optimal placement (Kakarla grade 1: 57.6% vs 37.3%; p < .001), lower rates of erroneous placement (Kakarla grade 3: 21.2% vs 40.7%; p < .001), a lower distance-to-target (median, 7.2 mm vs 11.4 mm; p < .001) and lower angular inaccuracy (median, 5.58° vs 7.60°; p < .001). Procedural time was longer for AR (median, 7 min 30 s vs 1 min 11 s; p < .001). Participants rated the AR system favorably on the USE for ease of learning (mean, 6.09/7 [SD, 0.94]) and satisfaction (mean, 6.45/7 [SD, 0.69]), while NASA-TLX scores indicated similar workloads between AR and freehand techniques. Conclusions: AR improves the accuracy of EVD placement compared to the freehand technique, which is expected to improve the efficacy in clinical settings. It increases total procedural time but remains within clinically acceptable limits and provides favorable usability.
- 10 July 2025
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 30 (3) , 414-421
External Ventricular Drain Placement Using Active Augmented Reality Guidance: A Proof of Concept of a Clinically Integrable System
BACKGROUND AND OBJECTIVES: Suboptimal placement occurs in 26% of external ventricular drain (EVD) procedures performed using traditional freehand methods. We developed a low-cost augmented reality stereotactic navigation system aimed at improving accuracy and safety of the procedure, which is readily compatible with existing Picture Archiving and Communication Systems and automated image segmentation algorithms. METHODS: The system integrates cloud storage, image segmentation, trajectory planning, point-based image-to-patient registration, and real-time 3-dimensional guidance superimposed over the surgical field. As a proof of concept, 15 neurosurgeons, neurosurgical residents, and physician assistants used anatomical landmark–based registration to conduct 29 EVD placements on anatomical phantoms with small ventricles within a simulated surgical environment. From postoperative computed tomography, placement accuracy was assessed using the Kakarla grading scale, along with the distance to target and angular deviation. RESULTS: Twenty EVDs (69.0%; 95% CI, 52.1%-85.8%) were graded as optimal Kakarla 1 placements, 4 (13.8%; 95% CI, 1.2%-26.3%) as suboptimal Kakarla 2 placements, and 5 (17.2%; 95% CI, 3.5%-31.0%) as suboptimal Kakarla 3 placements. The mean distance to target was 9.49 mm (SD, 4.64 mm), and the mean angular deviation was 9.20° (SD, 6.35°). The mean workflow time was 22 minutes 45 seconds (SD, 11 minutes 38 seconds), and the system demonstrated a fiducial registration error of 4.00 mm (SD, 1.16 mm). Challenges related to human-computer interaction were identified, suggesting further refinement is needed to optimize usability. CONCLUSION: While the accuracy, user interface, and procedural time of the system require further refinement for clinical implementation, this proof of concept demonstrates the clinical and technical feasibility of an end-to-end 3-dimensional augmented reality system with the potential to enhance the safety and accuracy of EVD placements.
- 10 July 2025
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 30 (3) , 414-421
External Ventricular Drain Placement Using Active Augmented Reality Guidance: A Proof of Concept of a Clinically Integrable System
BACKGROUND AND OBJECTIVES: Suboptimal placement occurs in 26% of external ventricular drain (EVD) procedures performed using traditional freehand methods. We developed a low-cost augmented reality stereotactic navigation system aimed at improving accuracy and safety of the procedure, which is readily compatible with existing Picture Archiving and Communication Systems and automated image segmentation algorithms. METHODS: The system integrates cloud storage, image segmentation, trajectory planning, point-based image-to-patient registration, and real-time 3-dimensional guidance superimposed over the surgical field. As a proof of concept, 15 neurosurgeons, neurosurgical residents, and physician assistants used anatomical landmark–based registration to conduct 29 EVD placements on anatomical phantoms with small ventricles within a simulated surgical environment. From postoperative computed tomography, placement accuracy was assessed using the Kakarla grading scale, along with the distance to target and angular deviation. RESULTS: Twenty EVDs (69.0%; 95% CI, 52.1%-85.8%) were graded as optimal Kakarla 1 placements, 4 (13.8%; 95% CI, 1.2%-26.3%) as suboptimal Kakarla 2 placements, and 5 (17.2%; 95% CI, 3.5%-31.0%) as suboptimal Kakarla 3 placements. The mean distance to target was 9.49 mm (SD, 4.64 mm), and the mean angular deviation was 9.20° (SD, 6.35°). The mean workflow time was 22 minutes 45 seconds (SD, 11 minutes 38 seconds), and the system demonstrated a fiducial registration error of 4.00 mm (SD, 1.16 mm). Challenges related to human-computer interaction were identified, suggesting further refinement is needed to optimize usability. CONCLUSION: While the accuracy, user interface, and procedural time of the system require further refinement for clinical implementation, this proof of concept demonstrates the clinical and technical feasibility of an end-to-end 3-dimensional augmented reality system with the potential to enhance the safety and accuracy of EVD placements.
- Open Access
- 3 January 2025
- Published by Springer Nature in Journal of Medical Systems
- Vol. 49 (1) , 1-10
Development and Validation of a Neurosurgical Phantom for Simulating External Ventricular Drain Placement
This study aimed to develop and validate a cost-effective, customizable patient-specific phantom for simulating external ventricular drain placement, combining image segmentation, 3-D printing and molding techniques. Two variations of the phantom were created based on patient MRI data, integrating a realistic skin layer with anatomical landmarks, a 3-D printed skull, an agarose polysaccharide gel brain, and a ventricular cavity. To validate the phantom, 15 neurosurgeons, residents, and physician assistants performed 30 EVD placements. The effectiveness of the phantom as a training tool was assessed through a standardized user experience questionnaire, which evaluated the physical attributes, realism, and overall satisfaction. The mechanical properties of the phantom brain were quantified by measuring catheter insertion forces using a linear force tester to compare them to those experienced in real brain tissue. The study participants successfully completed EVD placements with a 76.7% optimal placement rate, which aligns with rates observed in clinical practice. Feedback highlighted the anatomical accuracy of the phantom and its value in enhancing surgical skills, though it also identified areas for improvement, particularly in the realism of the skin layer. Mechanical testing demonstrated that the insertion forces required were comparable to those encountered in actual brain tissue. The developed phantom offers a realistic, low-cost, and adaptable model for EVD simulation. This tool is particularly beneficial for both training and research, with future enhancements planned to improve the realism of the skin and incorporate more anatomical features to increase the fidelity of the simulation.
- 3 January 2025
- Published by Springer Nature in Journal of Medical Systems
- Vol. 49 (1) , 1-10
Open AccessDevelopment and Validation of a Neurosurgical Phantom for Simulating External Ventricular Drain Placement
This study aimed to develop and validate a cost-effective, customizable patient-specific phantom for simulating external ventricular drain placement, combining image segmentation, 3-D printing and molding techniques. Two variations of the phantom were created based on patient MRI data, integrating a realistic skin layer with anatomical landmarks, a 3-D printed skull, an agarose polysaccharide gel brain, and a ventricular cavity. To validate the phantom, 15 neurosurgeons, residents, and physician assistants performed 30 EVD placements. The effectiveness of the phantom as a training tool was assessed through a standardized user experience questionnaire, which evaluated the physical attributes, realism, and overall satisfaction. The mechanical properties of the phantom brain were quantified by measuring catheter insertion forces using a linear force tester to compare them to those experienced in real brain tissue. The study participants successfully completed EVD placements with a 76.7% optimal placement rate, which aligns with rates observed in clinical practice. Feedback highlighted the anatomical accuracy of the phantom and its value in enhancing surgical skills, though it also identified areas for improvement, particularly in the realism of the skin layer. Mechanical testing demonstrated that the insertion forces required were comparable to those encountered in actual brain tissue. The developed phantom offers a realistic, low-cost, and adaptable model for EVD simulation. This tool is particularly beneficial for both training and research, with future enhancements planned to improve the realism of the skin and incorporate more anatomical features to increase the fidelity of the simulation.
- 11 November 2024
- Published by Springer Nature
- Vol. 1462, 351-374
Augmented Reality in Neurosurgery
Augmented Reality (AR) involves superimposing digital content onto the real environment. AR has evolved into a viable tool in neurosurgery, enhancing intraoperative navigation, medical education and surgical training by integrating anatomical data with the real world. Neurosurgical AR relies on several key techniques to be successful, which includes image segmentation, model rendering, AR projection, and image-to-patient registration. For each of these technical components, different solutions exist, with each having their own advantages and limitations. Intraoperative AR applications cover diverse neurosurgical disciplines including vascular, oncological, spinal, and functional surgeries. Preliminary studies indicate that AR may improve the understanding of complex anatomical structures and offer sufficient accuracy for use as a navigational tool. Additionally, AR shows promise in enhancing surgical training and patient education through interactive 3D models, aiding in the comprehension of intricate anatomical details. Despite its potential, the widespread adoption of AR in clinical settings depends on overcoming technical limitations and validating its clinical efficacy.
- 11 November 2024
- Published by Springer Nature
- Vol. 1462, 351-374
Augmented Reality in Neurosurgery
Augmented Reality (AR) involves superimposing digital content onto the real environment. AR has evolved into a viable tool in neurosurgery, enhancing intraoperative navigation, medical education and surgical training by integrating anatomical data with the real world. Neurosurgical AR relies on several key techniques to be successful, which includes image segmentation, model rendering, AR projection, and image-to-patient registration. For each of these technical components, different solutions exist, with each having their own advantages and limitations. Intraoperative AR applications cover diverse neurosurgical disciplines including vascular, oncological, spinal, and functional surgeries. Preliminary studies indicate that AR may improve the understanding of complex anatomical structures and offer sufficient accuracy for use as a navigational tool. Additionally, AR shows promise in enhancing surgical training and patient education through interactive 3D models, aiding in the comprehension of intricate anatomical details. Despite its potential, the widespread adoption of AR in clinical settings depends on overcoming technical limitations and validating its clinical efficacy.
- Open Access
- 13 May 2019
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 17 (6) , 588-593
Clinical Accuracy of Holographic Navigation Using Point-Based Registration on Augmented-Reality Glasses
BACKGROUND: As current augmented-reality (AR) smart glasses are self-contained, powerful computers that project 3-dimensional holograms that can maintain their position in physical space, they could theoretically be used as a low-cost, stand-alone neuronavigation system. OBJECTIVE: To determine feasibility and accuracy of holographic neuronavigation (HN) using AR smart glasses. METHODS: We programmed a fully functioning neuronavigation system on commercially available smart glasses (HoloLens®, Microsoft, Redmond, Washington) and tested its accuracy and feasibility in the operating room. The fiducial registration error (FRE) was measured for both HN and conventional neuronavigation (CN) (Brainlab, Munich, Germany) by using point-based registration on a plastic head model. Subsequently, we measured HN and CN FRE on 3 patients. RESULTS: A stereoscopic view of the holograms was successfully achieved in all experiments. In plastic head measurements, the mean HN FRE was 7.2 ± 1.8 mm compared to the mean CN FRE of 1.9 ± 0.45 (mean difference: –5.3 mm; 95% confidence interval [CI]: –6.7 to –3.9). In the 3 patients, the mean HN FRE was 4.4 ± 2.5 mm compared to the mean CN FRE of 3.6 ± 0.5 (mean difference: –0.8 mm; 95% CI: –3.0 to 4.6). CONCLUSION: Owing to the potential benefits and promising results, we believe that HN could eventually find application in operating rooms. However, several improvements will have to be made before the device can be used in clinical practice.
- 13 May 2019
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 17 (6) , 588-593
Open AccessClinical Accuracy of Holographic Navigation Using Point-Based Registration on Augmented-Reality Glasses
BACKGROUND: As current augmented-reality (AR) smart glasses are self-contained, powerful computers that project 3-dimensional holograms that can maintain their position in physical space, they could theoretically be used as a low-cost, stand-alone neuronavigation system. OBJECTIVE: To determine feasibility and accuracy of holographic neuronavigation (HN) using AR smart glasses. METHODS: We programmed a fully functioning neuronavigation system on commercially available smart glasses (HoloLens®, Microsoft, Redmond, Washington) and tested its accuracy and feasibility in the operating room. The fiducial registration error (FRE) was measured for both HN and conventional neuronavigation (CN) (Brainlab, Munich, Germany) by using point-based registration on a plastic head model. Subsequently, we measured HN and CN FRE on 3 patients. RESULTS: A stereoscopic view of the holograms was successfully achieved in all experiments. In plastic head measurements, the mean HN FRE was 7.2 ± 1.8 mm compared to the mean CN FRE of 1.9 ± 0.45 (mean difference: –5.3 mm; 95% confidence interval [CI]: –6.7 to –3.9). In the 3 patients, the mean HN FRE was 4.4 ± 2.5 mm compared to the mean CN FRE of 3.6 ± 0.5 (mean difference: –0.8 mm; 95% CI: –3.0 to 4.6). CONCLUSION: Owing to the potential benefits and promising results, we believe that HN could eventually find application in operating rooms. However, several improvements will have to be made before the device can be used in clinical practice.