Maarten Bot
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Maarten Bot has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
Pepijn van Den Munckhof
Department of Neurosurgery, Amsterdam UMC, Amsterdam, the Netherlands
3 shared publicationsBachtiar Burhani
Department of Neurosurgery, St. Elisabeth Hospital, Tilburg, The Netherlands
2 shared publications- Eelco Wieger Hoving
Princess Maxima Center for Pediatric Oncology, Utrecht, The Netherlands
2 shared publications - Jesse A. M. van Doormaal
Department of Neurosurgery, University Medical Center Utrecht, Utrecht, The Netherlands
2 shared publications Joke Dijk
Department of Neurology and Clinical Neurophysiology, Amsterdam University Medical Center, Amsterdam, The Netherlands
2 shared publicationsMartijn Beudel
Department of Neurology and Clinical Neurophysiology, Amsterdam University Medical Center, Amsterdam, The Netherlands
2 shared publications
Latest Publications
- Open Access
- 24 December 2025
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 167 (1)
Comparing augmented reality-assisted and freehand external ventricular drain placement: a multicenter randomized controlled crossover phantom study
Background: External ventricular drain (EVD) placement is a common neurosurgical procedure with high rates of misplacement when performed using the freehand technique. With augmented reality (AR), the accuracy of EVD placement could be improved by providing a 3-D overlay, guiding optimal placement using a virtual trajectory superimposed over the patient. In this study, we aimed to assess the efficacy and usability of an AR application for assisting EVD placements which supported trajectory planning, point-based image-to-patient registration and 3-D stereoscopic projection. Method: We conducted a randomized controlled crossover trial involving 15 neurosurgical residents and one neurosurgeon, who performed 236 EVD procedures (118 AR-assisted and 118 freehand) on biomimetic phantoms. EVD placement accuracy was evaluated using the Kakarla scale, distance-to-target, angular inaccuracy, and depth inaccuracy. The total procedural time was recorded. The user experience was evaluated using the NASA Task Load Index (NASA-TLX) and the Usefulness, Satisfaction, and Ease of Use (USE) questionnaire. Results: AR-assisted placement achieved significantly higher rates of optimal placement (Kakarla grade 1: 57.6% vs 37.3%; p < .001), lower rates of erroneous placement (Kakarla grade 3: 21.2% vs 40.7%; p < .001), a lower distance-to-target (median, 7.2 mm vs 11.4 mm; p < .001) and lower angular inaccuracy (median, 5.58° vs 7.60°; p < .001). Procedural time was longer for AR (median, 7 min 30 s vs 1 min 11 s; p < .001). Participants rated the AR system favorably on the USE for ease of learning (mean, 6.09/7 [SD, 0.94]) and satisfaction (mean, 6.45/7 [SD, 0.69]), while NASA-TLX scores indicated similar workloads between AR and freehand techniques. Conclusions: AR improves the accuracy of EVD placement compared to the freehand technique, which is expected to improve the efficacy in clinical settings. It increases total procedural time but remains within clinically acceptable limits and provides favorable usability.
- 24 December 2025
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 167 (1)
Open AccessComparing augmented reality-assisted and freehand external ventricular drain placement: a multicenter randomized controlled crossover phantom study
Background: External ventricular drain (EVD) placement is a common neurosurgical procedure with high rates of misplacement when performed using the freehand technique. With augmented reality (AR), the accuracy of EVD placement could be improved by providing a 3-D overlay, guiding optimal placement using a virtual trajectory superimposed over the patient. In this study, we aimed to assess the efficacy and usability of an AR application for assisting EVD placements which supported trajectory planning, point-based image-to-patient registration and 3-D stereoscopic projection. Method: We conducted a randomized controlled crossover trial involving 15 neurosurgical residents and one neurosurgeon, who performed 236 EVD procedures (118 AR-assisted and 118 freehand) on biomimetic phantoms. EVD placement accuracy was evaluated using the Kakarla scale, distance-to-target, angular inaccuracy, and depth inaccuracy. The total procedural time was recorded. The user experience was evaluated using the NASA Task Load Index (NASA-TLX) and the Usefulness, Satisfaction, and Ease of Use (USE) questionnaire. Results: AR-assisted placement achieved significantly higher rates of optimal placement (Kakarla grade 1: 57.6% vs 37.3%; p < .001), lower rates of erroneous placement (Kakarla grade 3: 21.2% vs 40.7%; p < .001), a lower distance-to-target (median, 7.2 mm vs 11.4 mm; p < .001) and lower angular inaccuracy (median, 5.58° vs 7.60°; p < .001). Procedural time was longer for AR (median, 7 min 30 s vs 1 min 11 s; p < .001). Participants rated the AR system favorably on the USE for ease of learning (mean, 6.09/7 [SD, 0.94]) and satisfaction (mean, 6.45/7 [SD, 0.69]), while NASA-TLX scores indicated similar workloads between AR and freehand techniques. Conclusions: AR improves the accuracy of EVD placement compared to the freehand technique, which is expected to improve the efficacy in clinical settings. It increases total procedural time but remains within clinically acceptable limits and provides favorable usability.
- Open Access
- 8 September 2025
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 212, 111127
Staged Gamma Knife radiosurgery for large brain metastases: local control and the influence of systemic treatment
- 8 September 2025
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 212, 111127
Open AccessStaged Gamma Knife radiosurgery for large brain metastases: local control and the influence of systemic treatment
- 10 July 2025
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 30 (3) , 414-421
External Ventricular Drain Placement Using Active Augmented Reality Guidance: A Proof of Concept of a Clinically Integrable System
BACKGROUND AND OBJECTIVES: Suboptimal placement occurs in 26% of external ventricular drain (EVD) procedures performed using traditional freehand methods. We developed a low-cost augmented reality stereotactic navigation system aimed at improving accuracy and safety of the procedure, which is readily compatible with existing Picture Archiving and Communication Systems and automated image segmentation algorithms. METHODS: The system integrates cloud storage, image segmentation, trajectory planning, point-based image-to-patient registration, and real-time 3-dimensional guidance superimposed over the surgical field. As a proof of concept, 15 neurosurgeons, neurosurgical residents, and physician assistants used anatomical landmark–based registration to conduct 29 EVD placements on anatomical phantoms with small ventricles within a simulated surgical environment. From postoperative computed tomography, placement accuracy was assessed using the Kakarla grading scale, along with the distance to target and angular deviation. RESULTS: Twenty EVDs (69.0%; 95% CI, 52.1%-85.8%) were graded as optimal Kakarla 1 placements, 4 (13.8%; 95% CI, 1.2%-26.3%) as suboptimal Kakarla 2 placements, and 5 (17.2%; 95% CI, 3.5%-31.0%) as suboptimal Kakarla 3 placements. The mean distance to target was 9.49 mm (SD, 4.64 mm), and the mean angular deviation was 9.20° (SD, 6.35°). The mean workflow time was 22 minutes 45 seconds (SD, 11 minutes 38 seconds), and the system demonstrated a fiducial registration error of 4.00 mm (SD, 1.16 mm). Challenges related to human-computer interaction were identified, suggesting further refinement is needed to optimize usability. CONCLUSION: While the accuracy, user interface, and procedural time of the system require further refinement for clinical implementation, this proof of concept demonstrates the clinical and technical feasibility of an end-to-end 3-dimensional augmented reality system with the potential to enhance the safety and accuracy of EVD placements.
- 10 July 2025
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 30 (3) , 414-421
External Ventricular Drain Placement Using Active Augmented Reality Guidance: A Proof of Concept of a Clinically Integrable System
BACKGROUND AND OBJECTIVES: Suboptimal placement occurs in 26% of external ventricular drain (EVD) procedures performed using traditional freehand methods. We developed a low-cost augmented reality stereotactic navigation system aimed at improving accuracy and safety of the procedure, which is readily compatible with existing Picture Archiving and Communication Systems and automated image segmentation algorithms. METHODS: The system integrates cloud storage, image segmentation, trajectory planning, point-based image-to-patient registration, and real-time 3-dimensional guidance superimposed over the surgical field. As a proof of concept, 15 neurosurgeons, neurosurgical residents, and physician assistants used anatomical landmark–based registration to conduct 29 EVD placements on anatomical phantoms with small ventricles within a simulated surgical environment. From postoperative computed tomography, placement accuracy was assessed using the Kakarla grading scale, along with the distance to target and angular deviation. RESULTS: Twenty EVDs (69.0%; 95% CI, 52.1%-85.8%) were graded as optimal Kakarla 1 placements, 4 (13.8%; 95% CI, 1.2%-26.3%) as suboptimal Kakarla 2 placements, and 5 (17.2%; 95% CI, 3.5%-31.0%) as suboptimal Kakarla 3 placements. The mean distance to target was 9.49 mm (SD, 4.64 mm), and the mean angular deviation was 9.20° (SD, 6.35°). The mean workflow time was 22 minutes 45 seconds (SD, 11 minutes 38 seconds), and the system demonstrated a fiducial registration error of 4.00 mm (SD, 1.16 mm). Challenges related to human-computer interaction were identified, suggesting further refinement is needed to optimize usability. CONCLUSION: While the accuracy, user interface, and procedural time of the system require further refinement for clinical implementation, this proof of concept demonstrates the clinical and technical feasibility of an end-to-end 3-dimensional augmented reality system with the potential to enhance the safety and accuracy of EVD placements.
- Open Access
- 15 February 2023
- Published by Elsevier in Brain Stimulation
- Vol. 16 (1) , 205
Deep brain stimulation of the medial forebrain bundle in treatment-resistant depression: Preliminary results showing shift and sustained antidepressant effects
- 15 February 2023
- Published by Elsevier in Brain Stimulation
- Vol. 16 (1) , 205
Open AccessDeep brain stimulation of the medial forebrain bundle in treatment-resistant depression: Preliminary results showing shift and sustained antidepressant effects
- 23 February 2022
- Published by Elsevier in Neuromodulation: Technology at the Neural Interface
- Vol. 26 (2) , 333-339
Utilizing 7-Tesla Subthalamic Nucleus Connectivity in Deep Brain Stimulation for Parkinson Disease
- 23 February 2022
- Published by Elsevier in Neuromodulation: Technology at the Neural Interface
- Vol. 26 (2) , 333-339
Utilizing 7-Tesla Subthalamic Nucleus Connectivity in Deep Brain Stimulation for Parkinson Disease
- 25 September 2021
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 21 (6) , 533-539
Evaluating and Optimizing Dentato-Rubro-Thalamic-Tract Deterministic Tractography in Deep Brain Stimulation for Essential Tremor
BACKGROUND: Dentato-rubro-thalamic tract (DRT) deep brain stimulation (DBS) suppresses tremor in essential tremor (ET) patients. However, DRT depiction through tractography can vary depending on the included brain regions. Moreover, it is unclear which section of the DRT is optimal for DBS. OBJECTIVE: To evaluate deterministic DRT tractography and tremor control in DBS for ET. METHODS: After DBS surgery, DRT tractography was conducted in 37 trajectories (20 ET patients). Per trajectory, 5 different DRT depictions with various regions of interest (ROI) were constructed. Comparison resulted in a DRT depiction with highest correspondence to intraoperative tremor control. This DRT depiction was subsequently used for evaluation of short-term postoperative adverse and beneficial effects. RESULTS: Postoperative optimized DRT tractography employing the ROI motor cortex, posterior subthalamic area (PSA), and ipsilateral superior cerebellar peduncle and dentate nucleus best corresponded with intraoperative trajectories (92%) and active DBS contacts (93%) showing optimal tremor control. DRT tractography employing a red nucleus or ventral intermediate nucleus of the thalamus (VIM) ROI often resulted in a more medial course. Optimal stimulation was located in the section between VIM and PSA. CONCLUSION: This optimized deterministic DRT tractography strongly correlates with optimal tremor control. This technique is readily implementable for prospective evaluation in DBS target planning for ET.
- 25 September 2021
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 21 (6) , 533-539
Evaluating and Optimizing Dentato-Rubro-Thalamic-Tract Deterministic Tractography in Deep Brain Stimulation for Essential Tremor
BACKGROUND: Dentato-rubro-thalamic tract (DRT) deep brain stimulation (DBS) suppresses tremor in essential tremor (ET) patients. However, DRT depiction through tractography can vary depending on the included brain regions. Moreover, it is unclear which section of the DRT is optimal for DBS. OBJECTIVE: To evaluate deterministic DRT tractography and tremor control in DBS for ET. METHODS: After DBS surgery, DRT tractography was conducted in 37 trajectories (20 ET patients). Per trajectory, 5 different DRT depictions with various regions of interest (ROI) were constructed. Comparison resulted in a DRT depiction with highest correspondence to intraoperative tremor control. This DRT depiction was subsequently used for evaluation of short-term postoperative adverse and beneficial effects. RESULTS: Postoperative optimized DRT tractography employing the ROI motor cortex, posterior subthalamic area (PSA), and ipsilateral superior cerebellar peduncle and dentate nucleus best corresponded with intraoperative trajectories (92%) and active DBS contacts (93%) showing optimal tremor control. DRT tractography employing a red nucleus or ventral intermediate nucleus of the thalamus (VIM) ROI often resulted in a more medial course. Optimal stimulation was located in the section between VIM and PSA. CONCLUSION: This optimized deterministic DRT tractography strongly correlates with optimal tremor control. This technique is readily implementable for prospective evaluation in DBS target planning for ET.