MBMaarten Bot

Maarten Bot

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Maarten Bot has a total of 56 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparing augmented reality-assisted and freehand external ventricular drain placement: a multicenter randomized controlled crossover phantom study

    by Jesse A. M. van Doormaal, Elisa Colombo, Jasper M. van der Zee, Wouter D. Maathuis, Maarten Bot, Patrick O’dOnnell, Bachtiar Burhani, Luca Regli, Pierre A. J. T. Robe, Eelco W. Hoving, et al.

    Background: External ventricular drain (EVD) placement is a common neurosurgical procedure with high rates of misplacement when performed using the freehand technique. With augmented reality (AR), the accuracy of EVD placement could be improved by providing a 3-D overlay, guiding optimal placement using a virtual trajectory superimposed over the patient. In this study, we aimed to assess the efficacy and usability of an AR application for assisting EVD placements which supported trajectory planning, point-based image-to-patient registration and 3-D stereoscopic projection. Method: We conducted a randomized controlled crossover trial involving 15 neurosurgical residents and one neurosurgeon, who performed 236 EVD procedures (118 AR-assisted and 118 freehand) on biomimetic phantoms. EVD placement accuracy was evaluated using the Kakarla scale, distance-to-target, angular inaccuracy, and depth inaccuracy. The total procedural time was recorded. The user experience was evaluated using the NASA Task Load Index (NASA-TLX) and the Usefulness, Satisfaction, and Ease of Use (USE) questionnaire. Results: AR-assisted placement achieved significantly higher rates of optimal placement (Kakarla grade 1: 57.6% vs 37.3%; p < .001), lower rates of erroneous placement (Kakarla grade 3: 21.2% vs 40.7%; p < .001), a lower distance-to-target (median, 7.2 mm vs 11.4 mm; p < .001) and lower angular inaccuracy (median, 5.58° vs 7.60°; p < .001). Procedural time was longer for AR (median, 7 min 30 s vs 1 min 11 s; p < .001). Participants rated the AR system favorably on the USE for ease of learning (mean, 6.09/7 [SD, 0.94]) and satisfaction (mean, 6.45/7 [SD, 0.69]), while NASA-TLX scores indicated similar workloads between AR and freehand techniques. Conclusions: AR improves the accuracy of EVD placement compared to the freehand technique, which is expected to improve the efficacy in clinical settings. It increases total procedural time but remains within clinically acceptable limits and provides favorable usability.


  • Open Access

    Staged Gamma Knife radiosurgery for large brain metastases: local control and the influence of systemic treatment

    by R.G. Huisman, P. van Schie, L.G. Merckel, T. Wiersma, J.L. Knegjens, E.P.M. Jansen, A. Compter, D. Brandsma, M. Bot, J. Hoogmoed, et al.


  • External Ventricular Drain Placement Using Active Augmented Reality Guidance: A Proof of Concept of a Clinically Integrable System

    by Jesse A. M. van Doormaal, Tim Fick, Jene W. Meulstee, Tessa M. Kos, Maarten Bot, Patrick O'DOnnell, Bachtiar Burhani, Pierre A. J. T. Robe, Eelco W. Hoving, Tristan P. C. van Doormaal

    BACKGROUND AND OBJECTIVES: Suboptimal placement occurs in 26% of external ventricular drain (EVD) procedures performed using traditional freehand methods. We developed a low-cost augmented reality stereotactic navigation system aimed at improving accuracy and safety of the procedure, which is readily compatible with existing Picture Archiving and Communication Systems and automated image segmentation algorithms. METHODS: The system integrates cloud storage, image segmentation, trajectory planning, point-based image-to-patient registration, and real-time 3-dimensional guidance superimposed over the surgical field. As a proof of concept, 15 neurosurgeons, neurosurgical residents, and physician assistants used anatomical landmark–based registration to conduct 29 EVD placements on anatomical phantoms with small ventricles within a simulated surgical environment. From postoperative computed tomography, placement accuracy was assessed using the Kakarla grading scale, along with the distance to target and angular deviation. RESULTS: Twenty EVDs (69.0%; 95% CI, 52.1%-85.8%) were graded as optimal Kakarla 1 placements, 4 (13.8%; 95% CI, 1.2%-26.3%) as suboptimal Kakarla 2 placements, and 5 (17.2%; 95% CI, 3.5%-31.0%) as suboptimal Kakarla 3 placements. The mean distance to target was 9.49 mm (SD, 4.64 mm), and the mean angular deviation was 9.20° (SD, 6.35°). The mean workflow time was 22 minutes 45 seconds (SD, 11 minutes 38 seconds), and the system demonstrated a fiducial registration error of 4.00 mm (SD, 1.16 mm). Challenges related to human-computer interaction were identified, suggesting further refinement is needed to optimize usability. CONCLUSION: While the accuracy, user interface, and procedural time of the system require further refinement for clinical implementation, this proof of concept demonstrates the clinical and technical feasibility of an end-to-end 3-dimensional augmented reality system with the potential to enhance the safety and accuracy of EVD placements.


  • Open Access

    Deep brain stimulation of the medial forebrain bundle in treatment-resistant depression: Preliminary results showing shift and sustained antidepressant effects

    by Gosse Jacobus Johannes Mol, Nora Runia, Roel J.T. Mocking, Dirk de Knijff, Pepijn van Den Munckhof, Maarten Bot, Hilko Ardon, Dieuwertje A. de Waardt, Geert-Jan M. Rutten, P. Rick Schuurman, et al.

  • Utilizing 7-Tesla Subthalamic Nucleus Connectivity in Deep Brain Stimulation for Parkinson Disease

    by Varvara Mathiopoulou, Niels Rijks, Matthan W.A. Caan, Luka C. Liebrand, Francisca Ferreira, Rob M.A. de Bie, Pepijn van Den Munckhof, P. Richard Schuurman, Maarten Bot


  • The Fast Gray Matter Acquisition T1 Inversion Recovery Sequence in Deep Brain Stimulation: Introducing the Rubral Wing for Dentato-Rubro-Thalamic Tract Depiction and Tremor Control

    by Maarten Bot, Rik Pauwels, Pepijn van Den Munckhof, Maartje de Win, Vincent J.J. Odekerken, Martijn Beudel, Joke Dijk, Rob M.A. de Bie, P. Richard Schuurman


  • Evaluating and Optimizing Dentato-Rubro-Thalamic-Tract Deterministic Tractography in Deep Brain Stimulation for Essential Tremor

    by Maarten Bot, Anne-Fleur van Rootselaari, Vincent Odekerken, Joke Dijk, Rob M A de Bie, Martijn Beudel, Pepijn van Den Munckhof, P Richard Schuurman

    BACKGROUND: Dentato-rubro-thalamic tract (DRT) deep brain stimulation (DBS) suppresses tremor in essential tremor (ET) patients. However, DRT depiction through tractography can vary depending on the included brain regions. Moreover, it is unclear which section of the DRT is optimal for DBS. OBJECTIVE: To evaluate deterministic DRT tractography and tremor control in DBS for ET. METHODS: After DBS surgery, DRT tractography was conducted in 37 trajectories (20 ET patients). Per trajectory, 5 different DRT depictions with various regions of interest (ROI) were constructed. Comparison resulted in a DRT depiction with highest correspondence to intraoperative tremor control. This DRT depiction was subsequently used for evaluation of short-term postoperative adverse and beneficial effects. RESULTS: Postoperative optimized DRT tractography employing the ROI motor cortex, posterior subthalamic area (PSA), and ipsilateral superior cerebellar peduncle and dentate nucleus best corresponded with intraoperative trajectories (92%) and active DBS contacts (93%) showing optimal tremor control. DRT tractography employing a red nucleus or ventral intermediate nucleus of the thalamus (VIM) ROI often resulted in a more medial course. Optimal stimulation was located in the section between VIM and PSA. CONCLUSION: This optimized deterministic DRT tractography strongly correlates with optimal tremor control. This technique is readily implementable for prospective evaluation in DBS target planning for ET.