A novel Q‐value‐based nomogram for single intracorneal ring segment implantation versus standard manufacturer's nomogram combined with accelerated cross‐linking for treatment of keratoconus: a randomized controlled trial
Open Access
- 15 September 2020
- journal article
- research article
- Published by Wiley in Acta Ophthalmologica
- Vol. 99 (4) , E501-E511
Abstract
Purpose To compare the efficacy of implanting a single Keraring segment according to a novel Q‐value‐based nomogram (QN) to that of segment implantation according to the manufacturer's standard nomogram (SN), for keratoconus treatment. Methods This was a prospective, randomized controlled trial of 104 patients (104 eyes) with Amsler‐Krumeich grade 1 or 2 keratoconus, and type 1 or 2 cone asymmetry determined according to manufacturer's classification. They were randomly distributed into two groups: group A patients (n = 52) underwent Keraring implantation according to the SN, and group B patients (n = 52) underwent implantation of a single (210° arc‐length) Keraring segment according to the QN. Both treatments were combined with accelerated transepithelial cross‐linking, and follow‐up was 6 months. Main outcome measures were preoperative and postoperative visual acuity, subjective refraction and corneal topography. Results At postoperative month 6, group B exhibited statistically significantly higher values of mean uncorrected distance visual acuity (UDVA), sphere, K2, K‐average, K‐max and Q‐anterior (p = 0.02, 0.01, 0.002, 0.001, 0.0001 and 0.03, respectively) compared to that of group A. However, group A exhibited better refractive cylindrical improvements (p = 0.04). In group A, we documented spontaneous extrusion of one Keraring segment. Conclusion Single 210° arc‐length segment implantation using our objective QN was more efficacious for keratoconus treatment than using the subjective SN. The nomograms were comparable when the Q‐anterior value was >−1.00; however, the QN was superior to the SN when the Q‐anterior value was ≤−1.00. The QN yielded greater postoperative UDVA and smoother corneal remodelling than did the SN for treatment of grade 1 and 2 keratoconic eyes.Keywords
This publication has 44 references indexed in Scilit:
- Transepithelial Versus Epithelium-off Corneal Cross-linking for the Treatment of Progressive Keratoconus: A Randomized Controlled TrialAmerican Journal of Ophthalmology, 2015
- Femtosecond laser intracorneal ring segment implantation based on a nomogram modification in type 1 and type 2 ectasiaJournal of the Egyptian Ophthalmological Society, 2015
- Corneal Collagen Cross-linking (CXL) Combined With Refractive Procedures for the Treatment of Corneal Ectatic Disorders: CXL PlusJournal of Refractive Surgery, 2014
- Intrastromal corneal ring segments: How successful is the surgical treatment of keratoconus?Middle East African Journal of Ophthalmology, 2014
- Outcomes of intrastromal corneal ring segments for treatment of keratoconus: Five-year follow-up analysisJournal of Cataract & Refractive Surgery, 2013
- Correlation of Anterior Segment Parameters in Keratoconus PatientsInternational Journal of Keratoconus and Ectatic Corneal Diseases, 2012
- Detection of Biomechanical Changes After Corneal Cross-Linking Using Ocular Response Analyzer SoftwareJournal of Refractive Surgery, 2011
- Histopathological findings after intracorneal ring segment implantation in keratoconic human corneasJournal of Cataract & Refractive Surgery, 2007
- Evaluation of Intrastromal Lipid Deposits After Intacs Implantation Using In Vivo Confocal MicroscopyEye & Contact Lens: Science & Clinical Practice, 2006
- The Mean Shape of the Human CorneaOptica Acta: International Journal of Optics, 1982