Ola Ibrahim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ola Ibrahim has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Ashraf Soliman
Department of Ophthalmology, Faculty of medicine, Ain-Shams University
2 shared publications - Mohammed Iqbal
Department of Ophthalmology, Faculty of Medicine, Sohag University, Sohag, Egypt
2 shared publications - Ahmed Elmassry
Department of Ophthalmology, Faculty of Medicine, Alexandria University, Alexandria, Egypt
1 shared publication - Amr Mounir
Department of Ophthalmology, Faculty of Medicine, Sohag University, Sohag, Egypt
1 shared publication - Omar M. Said
Department of Ophthalmology, Faculty of Medicine, Fayoum University, Fayoum, Egypt
1 shared publication
Latest Publications
- Open Access
- 1 January 2021
- Published by Wiley in Journal of Ophthalmology
- Vol. 2021 (1)
Visual Sequelae of Computer Vision Syndrome: A Cross‐Sectional Case‐Control Study
Purpose . To assess the visual, ocular, extraocular, and multifocal electroretinography (mfERG) outcomes of computer vision syndrome (CVS) among medical students. Methods . This study was designed as a cross‐sectional case‐control study that included 733 medical students. All students completed a specially designed and validated CVS questionnaire survey (CVS‐F3). Students from the control (No‐CVS) and CVS groups underwent comprehensive ophthalmic examinations including the mfERG examinations. Our main outcome measures included uncorrected and corrected distance visual acuity (UDVA and CDVA, resp.) measurements, subjective and cycloplegic refractions, slit‐lamp examination, intraocular pressure measurement, pupillary reflexes tests, ocular movements’ tests, dry eye disease tests, and fundus and mfERG examinations. Results . The CVS‐F3 identified that 87.9% of students had complaints that might be related to CVS. We documented a 76% prevalence rate in students undergoing an ophthalmologic exam. The most common ocular and extraocular complaints included visual blur and headache (40.9% and 46.8%, resp.). Statistical logistic and linear regression analyses showed that refractive errors, prolonged screen‐hours, close eye‐screen distance, improper gaze angle, poor screen‐resolution, and screen‐glare were risk factors for developing CVS and influencing its severity. In the mfERG subgroup, 42.5% demonstrated reduced amplitudes of mfERG rings and quadrants, indicating reduced foveal responses. Conclusion . Surveys cannot yield an accurate CVS prevalence. However, they help to identify subjects at risk who should be comprehensively assessed to confirm or exclude CVS diagnosis. Smartphone misuse primarily caused CVS among users. Our mfERG findings might be a sign of potential CVS visual sequelae; however, future studies are warranted. Clinicians need to understand these sequelae to appropriately identify and treat CVS.
- 1 January 2021
- Published by Wiley in Journal of Ophthalmology
- Vol. 2021 (1)
Open AccessVisual Sequelae of Computer Vision Syndrome: A Cross‐Sectional Case‐Control Study
Purpose . To assess the visual, ocular, extraocular, and multifocal electroretinography (mfERG) outcomes of computer vision syndrome (CVS) among medical students. Methods . This study was designed as a cross‐sectional case‐control study that included 733 medical students. All students completed a specially designed and validated CVS questionnaire survey (CVS‐F3). Students from the control (No‐CVS) and CVS groups underwent comprehensive ophthalmic examinations including the mfERG examinations. Our main outcome measures included uncorrected and corrected distance visual acuity (UDVA and CDVA, resp.) measurements, subjective and cycloplegic refractions, slit‐lamp examination, intraocular pressure measurement, pupillary reflexes tests, ocular movements’ tests, dry eye disease tests, and fundus and mfERG examinations. Results . The CVS‐F3 identified that 87.9% of students had complaints that might be related to CVS. We documented a 76% prevalence rate in students undergoing an ophthalmologic exam. The most common ocular and extraocular complaints included visual blur and headache (40.9% and 46.8%, resp.). Statistical logistic and linear regression analyses showed that refractive errors, prolonged screen‐hours, close eye‐screen distance, improper gaze angle, poor screen‐resolution, and screen‐glare were risk factors for developing CVS and influencing its severity. In the mfERG subgroup, 42.5% demonstrated reduced amplitudes of mfERG rings and quadrants, indicating reduced foveal responses. Conclusion . Surveys cannot yield an accurate CVS prevalence. However, they help to identify subjects at risk who should be comprehensively assessed to confirm or exclude CVS diagnosis. Smartphone misuse primarily caused CVS among users. Our mfERG findings might be a sign of potential CVS visual sequelae; however, future studies are warranted. Clinicians need to understand these sequelae to appropriately identify and treat CVS.
- Open Access
- 15 September 2020
- Published by Wiley in Acta Ophthalmologica
- Vol. 99 (4) , E501-E511
A novel Q‐value‐based nomogram for single intracorneal ring segment implantation versus standard manufacturer's nomogram combined with accelerated cross‐linking for treatment of keratoconus: a randomized controlled trial
Purpose To compare the efficacy of implanting a single Keraring segment according to a novel Q‐value‐based nomogram (QN) to that of segment implantation according to the manufacturer's standard nomogram (SN), for keratoconus treatment. Methods This was a prospective, randomized controlled trial of 104 patients (104 eyes) with Amsler‐Krumeich grade 1 or 2 keratoconus, and type 1 or 2 cone asymmetry determined according to manufacturer's classification. They were randomly distributed into two groups: group A patients (n = 52) underwent Keraring implantation according to the SN, and group B patients (n = 52) underwent implantation of a single (210° arc‐length) Keraring segment according to the QN. Both treatments were combined with accelerated transepithelial cross‐linking, and follow‐up was 6 months. Main outcome measures were preoperative and postoperative visual acuity, subjective refraction and corneal topography. Results At postoperative month 6, group B exhibited statistically significantly higher values of mean uncorrected distance visual acuity (UDVA), sphere, K2, K‐average, K‐max and Q‐anterior (p = 0.02, 0.01, 0.002, 0.001, 0.0001 and 0.03, respectively) compared to that of group A. However, group A exhibited better refractive cylindrical improvements (p = 0.04). In group A, we documented spontaneous extrusion of one Keraring segment. Conclusion Single 210° arc‐length segment implantation using our objective QN was more efficacious for keratoconus treatment than using the subjective SN. The nomograms were comparable when the Q‐anterior value was >−1.00; however, the QN was superior to the SN when the Q‐anterior value was ≤−1.00. The QN yielded greater postoperative UDVA and smoother corneal remodelling than did the SN for treatment of grade 1 and 2 keratoconic eyes.
- 15 September 2020
- Published by Wiley in Acta Ophthalmologica
- Vol. 99 (4) , E501-E511
Open AccessA novel Q‐value‐based nomogram for single intracorneal ring segment implantation versus standard manufacturer's nomogram combined with accelerated cross‐linking for treatment of keratoconus: a randomized controlled trial
Purpose To compare the efficacy of implanting a single Keraring segment according to a novel Q‐value‐based nomogram (QN) to that of segment implantation according to the manufacturer's standard nomogram (SN), for keratoconus treatment. Methods This was a prospective, randomized controlled trial of 104 patients (104 eyes) with Amsler‐Krumeich grade 1 or 2 keratoconus, and type 1 or 2 cone asymmetry determined according to manufacturer's classification. They were randomly distributed into two groups: group A patients (n = 52) underwent Keraring implantation according to the SN, and group B patients (n = 52) underwent implantation of a single (210° arc‐length) Keraring segment according to the QN. Both treatments were combined with accelerated transepithelial cross‐linking, and follow‐up was 6 months. Main outcome measures were preoperative and postoperative visual acuity, subjective refraction and corneal topography. Results At postoperative month 6, group B exhibited statistically significantly higher values of mean uncorrected distance visual acuity (UDVA), sphere, K2, K‐average, K‐max and Q‐anterior (p = 0.02, 0.01, 0.002, 0.001, 0.0001 and 0.03, respectively) compared to that of group A. However, group A exhibited better refractive cylindrical improvements (p = 0.04). In group A, we documented spontaneous extrusion of one Keraring segment. Conclusion Single 210° arc‐length segment implantation using our objective QN was more efficacious for keratoconus treatment than using the subjective SN. The nomograms were comparable when the Q‐anterior value was >−1.00; however, the QN was superior to the SN when the Q‐anterior value was ≤−1.00. The QN yielded greater postoperative UDVA and smoother corneal remodelling than did the SN for treatment of grade 1 and 2 keratoconic eyes.