Paulo Jose Coelho Canavezi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Paulo Jose Coelho Canavezi has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Adriana Mendes Vinagre
Departament of Pediatrics, Faculty of Medical Sciences, State University of Campinas, 13083-887 Campinas, SP, Brazil
1 shared publication - Adyléia Aparecida Dalbo Contrera Toro
Department of Pediatric, State University of Campinas (UNICAMP), Campinas, São Paulo, Brazil
1 shared publication - Antonio Fernando Ribeiro
Department of Pediatrics, School of Medical Sciences, University of Campinas, Rua Tessália Vieira de Camargo, 126, Cidade Universitária Zeferino Vaz, Campinas, SP, CEP 13083-887, Brazil
1 shared publication - Carla Cristina Souza Gomez
Center for Investigation in Pediatrics, Department of Pediatrics, Faculdade de Ciências Médicas, Universidade Estadual de Campinas, 126, Tessália Vieira de Camargo, Campinas, São Paulo, 13083-887, Brazil.
1 shared publication - Celia Regina Pavan
Gastrocentro - Endoscopy Unit - State University of Campinas (Unicamp), Cidade Universitária Zeferino Vaz - Barão Geraldo, 13083-872 Campinas, SP, Brazil
1 shared publication - Eduardo Tavares Costa
State University of Campinas (UNICAMP)
1 shared publication
Latest Publications
- Open Access
- 13 December 2014
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 14 (1) , 198
Pulsed direct and constant direct currents in the pilocarpine iontophoresis sweat chloride test
The classic sweat test (CST) is the golden standard for cystic fibrosis (CF) diagnosis. Then, our aim was compare the production and volume of sweat, and side effects caused by pulsed direct current (PDC) and constant direct current (CDC). To determine the optimal stimulation time (ST) for the sweat collection. To verify the PDC as CF diagnosis option. Prospective study with cross-sectional experimental intervention. Experiment 1 (right arm): PDC and CDC. ST at 10 min and sweat collected at 30 min. Currents of 0.5; 0.75; 1.0 and 1.5 mA and frequencies of 0, 200, 1,000 and 5,000 Hz applied. Experiment 2 (left arm): current of 1.0 mA, ST at 5 and 10 min and sweat collected at 15 and 30 min with frequencies of 0; 200; 1,000 and 5,000 Hz applied Experiments 1 and 2 were performed with current density (CD) from 0.07 to 0.21 mA/cm2. Experiment 3: PDC was used in typical CF patients with two CFTR mutations screened and or with CF diagnosis by rectal biopsy and patients with atypical CF. 48 subjects (79.16% female) with average of 29.54 ± 8.87 years old were enrolled. There was no statistical difference between the interaction of frequency and current in the sweat weight (p = 0.7488). Individually, positive association was achieved between weight sweat and stimulation frequency (p = 0.0088); and current (p = 0.0025). The sweat production was higher for 10 min of stimulation (p = 0.0023). The sweat collection was better for 30 min (p = 0.0019). The skin impedance was not influenced by ST and sweat collection (p > 0.05). The current frequency was inversely associated with the skin impedance (p < 0.0001). The skin temperature measured before stimulation was higher than after (p < 0.0001). In Experiment 3 (29 subjects) the PDC showed better kappa index compared to CDC (0.9218 versus 0.5205, respectively). The performance of the CST with CDC and PDC with CD of 0.14 to 0.21 mA/cm2 showed efficacy in steps of stimulation and collection of sweat, without side effects. The optimal stimulation time and sweat collection were, respectively, 10 and 30 min.
- 13 December 2014
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 14 (1) , 198
Open AccessPulsed direct and constant direct currents in the pilocarpine iontophoresis sweat chloride test
The classic sweat test (CST) is the golden standard for cystic fibrosis (CF) diagnosis. Then, our aim was compare the production and volume of sweat, and side effects caused by pulsed direct current (PDC) and constant direct current (CDC). To determine the optimal stimulation time (ST) for the sweat collection. To verify the PDC as CF diagnosis option. Prospective study with cross-sectional experimental intervention. Experiment 1 (right arm): PDC and CDC. ST at 10 min and sweat collected at 30 min. Currents of 0.5; 0.75; 1.0 and 1.5 mA and frequencies of 0, 200, 1,000 and 5,000 Hz applied. Experiment 2 (left arm): current of 1.0 mA, ST at 5 and 10 min and sweat collected at 15 and 30 min with frequencies of 0; 200; 1,000 and 5,000 Hz applied Experiments 1 and 2 were performed with current density (CD) from 0.07 to 0.21 mA/cm2. Experiment 3: PDC was used in typical CF patients with two CFTR mutations screened and or with CF diagnosis by rectal biopsy and patients with atypical CF. 48 subjects (79.16% female) with average of 29.54 ± 8.87 years old were enrolled. There was no statistical difference between the interaction of frequency and current in the sweat weight (p = 0.7488). Individually, positive association was achieved between weight sweat and stimulation frequency (p = 0.0088); and current (p = 0.0025). The sweat production was higher for 10 min of stimulation (p = 0.0023). The sweat collection was better for 30 min (p = 0.0019). The skin impedance was not influenced by ST and sweat collection (p > 0.05). The current frequency was inversely associated with the skin impedance (p < 0.0001). The skin temperature measured before stimulation was higher than after (p < 0.0001). In Experiment 3 (29 subjects) the PDC showed better kappa index compared to CDC (0.9218 versus 0.5205, respectively). The performance of the CST with CDC and PDC with CD of 0.14 to 0.21 mA/cm2 showed efficacy in steps of stimulation and collection of sweat, without side effects. The optimal stimulation time and sweat collection were, respectively, 10 and 30 min.