The anoxic corrosion behaviour of copper in the presence of chloride and sulphide
- 29 July 2020
- journal article
- research article
- Published by Wiley in Materials and Corrosion
- Vol. 72 (1-2) , 282-292
Abstract
The Canadian used fuel container for the long‐term containment of spent nuclear fuel in a deep geological repository comprises a 3‐mm copper corrosion barrier applied directly to a strong carbon steel container. Although a final site for the Canadian deep geological repository has not yet been chosen, the site selection process has narrowed down to two candidate locations with unique groundwater chemistry, particularly with respect to salinity. Therefore, to ensure the long‐term integrity of the used fuel container, the effect of a range of groundwater chemistries on copper corrosion must be understood. The primary variables of interest are the influence of chloride concentration and the consequences of the interaction of hydrogen sulphide, naturally present in the groundwaters in very low concentrations, with the copper cladding. An additional aspect that has been investigated is the behaviour of copper in pure water. The anoxic corrosion of copper can be inferred by the very slow release of hydrogen gas. In this paper, new data are presented, which demonstrate an extremely sensitive approach to quantify the very limited hydrogen release at 75°C. Initially, corrosion rates under conditions approximating an anticipated Canadian deep geological repository were significantly less than 0.5 nm/year and they invariably declined over the course of several months/years. The presence of chloride or hydrogen sulphide was found, under specific conditions, to stimulate short‐term corrosion behaviour, which was consistent with anion‐assisted surface rearrangement, not bulk corrosion.Keywords
Funding Information
- Nuclear Waste Management Organization
This publication has 37 references indexed in Scilit:
- Long-term corrosion of copper in a dilute anaerobic sulfide solutionElectrochimica Acta, 2011
- An equilibrium ab initio atomistic thermodynamics study of chlorine adsorption on the Cu(001) surfacePhysical Chemistry Chemical Physics, 2011
- Kinetics of Corrosion Film Growth on Copper in Neutral Chloride Solutions Containing Small Concentrations of SulfideJournal of the Electrochemical Society, 2010
- Oxidation of Polycrystalline Copper Thin Films at Ambient ConditionsThe Journal of Physical Chemistry C, 2008
- The Electrochemical Response of Preoxidized Copper in Aqueous Sulfide SolutionsJournal of the Electrochemical Society, 2007
- Corrosion of Copper by WaterElectrochemical and Solid-State Letters, 2007
- Dissolution of a Complex Borosilicate Glass at 60°C: The Influence of pH and Proton Adsorption on the Congruence of Short-Term LeachingMRS Proceedings, 1997
- Scanning Tunneling Microscopic Study with Atomic Resolution of the Dissolution of Cu(111) in Aqueous Chloride SolutionsJournal of the American Chemical Society, 1994
- Dissolution Rates of Commercial Soda–Lime and Pyrex Borosilicate Glasses: Influence of Solution pHJournal of the American Ceramic Society, 1991
- Computer simulations of corrosion: Selective dissolution of binary alloysPhilosophical Magazine A, 1989