Taylor Martino
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Taylor Martino has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Jian Chen
Department of Chemistry University of Western Ontario London Ontario Canada
5 shared publications - James Joseph Noël
Department of Chemistry University of Western Ontario London Ontario Canada
4 shared publications - Nicholas A. Senior
Natural Resources Canada, CanmetMATERIALS, Hamilton Ontario Canada
4 shared publications D. W. Shoesmith
Department of Chemistry, The University of Western Ontario, London, Canada
3 shared publications- Nikitas Diomidis
National Cooperative for the Disposal of Radioactive Waste Wettingen Aargau Switzerland
3 shared publications David W. Shoesmith
Department of Chemistry University of Western Ontario London Ontario Canada
2 shared publications
Latest Publications
- 5 November 2026
- Published by Wiley in Materials and Corrosion
The Use of Low‐Cost Commercial Hydrogen Sensors for Thermal Desorption Research
The corrosion of metallic materials under anoxic deep geological repository (DGR) conditions inevitably results in the evolution of hydrogen. From a research perspective, this hydrogen provides an approach to understanding the uniform corrosion rates of materials as well as the inventory of hydrogen that can accumulate within the repository. The corroding metals themselves are hydrogen sinks; thus, it is important to understand how much hydrogen is absorbed as a function of concentration, pH and temperature. For metallic packages that will contain highly hazardous nuclear waste, potential changes to mechanical properties due to hydrogen absorption must be understood. For experimental work supporting the safety of DGR science, absorption or desorption of hydrogen can impact the corrosion rate calculations, complicating safety assessments. To address these issues, a thermal desorption analyser has been developed to characterise materials used in corrosion experiments. The analyser is simple to construct and operate and yields excellent sensitivity using a commercially‐available hydrogen sensor. This article describes the design and capabilities of this analyser.
- 5 November 2026
- Published by Wiley in Materials and Corrosion
The Use of Low‐Cost Commercial Hydrogen Sensors for Thermal Desorption Research
The corrosion of metallic materials under anoxic deep geological repository (DGR) conditions inevitably results in the evolution of hydrogen. From a research perspective, this hydrogen provides an approach to understanding the uniform corrosion rates of materials as well as the inventory of hydrogen that can accumulate within the repository. The corroding metals themselves are hydrogen sinks; thus, it is important to understand how much hydrogen is absorbed as a function of concentration, pH and temperature. For metallic packages that will contain highly hazardous nuclear waste, potential changes to mechanical properties due to hydrogen absorption must be understood. For experimental work supporting the safety of DGR science, absorption or desorption of hydrogen can impact the corrosion rate calculations, complicating safety assessments. To address these issues, a thermal desorption analyser has been developed to characterise materials used in corrosion experiments. The analyser is simple to construct and operate and yields excellent sensitivity using a commercially‐available hydrogen sensor. This article describes the design and capabilities of this analyser.
- 1 December 2020
- Published by Wiley in Materials and Corrosion
- Vol. 72 (1-2) , 67-74
The corrosion of mild and stainless steel in alkaline anaerobic conditions representing the Belgian “supercontainer” concept and the Swiss L/ILW repository
Deep geological repositories for radioactive waste contain metallic materials, either used to construct disposal canisters or as low‐/intermediate‐level waste (L/ILW). The safety relevance of corrosion is linked to canister lifetime in the former case and gas generation in the latter. More specifically, the Belgian “supercontainer” concept envisages mild steel for the used fuel disposal canister, and in the case of the Swiss L/ILW repository, mild steels are the largest metallic waste component due to the decommissioning of civilian power‐generating facilities. For these circumstances, the corrosion environment is dominated by the chemistry of cement, which is used as buffer or backfill material. The corrosion behaviour of mild steel in anoxic environments was studied through the analysis of the hydrogen end‐product. Hydrogen analysis was conducted by periodically purging the cell head‐space and analysing the gas using a solid‐state hydrogen sensor. While this method is limited to providing only uniform corrosion rates averaged over periods of time, ranging from weeks to months, it provides excellent resolution and sensitivity. The test cell environments were matched against the anticipated Belgian high‐level waste and Swiss L/ILW repository environments, and also against experiments that have been conducted by other researchers for comparative purposes. Samples were exposed to synthetic cement pore waters, representing fresh and degraded cement. In young cement waters, the formation of initial corrosion products resulted in steel wire corrosion rates of the order of µm/year, which, at 80°C rapidly declined to ∼10 nm/year. In contrast, SA516 grade 70 steel plate corroded much more slowly under similar conditions. In aged cement waters, initial corrosion rates were higher but declined faster towards a longer‐term rate of ∼10 nm/year. 316L stainless steel, embedded in cementitious material, corroded at a rate of <1 nm/year at 50°C.
- 1 December 2020
- Published by Wiley in Materials and Corrosion
- Vol. 72 (1-2) , 67-74
The corrosion of mild and stainless steel in alkaline anaerobic conditions representing the Belgian “supercontainer” concept and the Swiss L/ILW repository
Deep geological repositories for radioactive waste contain metallic materials, either used to construct disposal canisters or as low‐/intermediate‐level waste (L/ILW). The safety relevance of corrosion is linked to canister lifetime in the former case and gas generation in the latter. More specifically, the Belgian “supercontainer” concept envisages mild steel for the used fuel disposal canister, and in the case of the Swiss L/ILW repository, mild steels are the largest metallic waste component due to the decommissioning of civilian power‐generating facilities. For these circumstances, the corrosion environment is dominated by the chemistry of cement, which is used as buffer or backfill material. The corrosion behaviour of mild steel in anoxic environments was studied through the analysis of the hydrogen end‐product. Hydrogen analysis was conducted by periodically purging the cell head‐space and analysing the gas using a solid‐state hydrogen sensor. While this method is limited to providing only uniform corrosion rates averaged over periods of time, ranging from weeks to months, it provides excellent resolution and sensitivity. The test cell environments were matched against the anticipated Belgian high‐level waste and Swiss L/ILW repository environments, and also against experiments that have been conducted by other researchers for comparative purposes. Samples were exposed to synthetic cement pore waters, representing fresh and degraded cement. In young cement waters, the formation of initial corrosion products resulted in steel wire corrosion rates of the order of µm/year, which, at 80°C rapidly declined to ∼10 nm/year. In contrast, SA516 grade 70 steel plate corroded much more slowly under similar conditions. In aged cement waters, initial corrosion rates were higher but declined faster towards a longer‐term rate of ∼10 nm/year. 316L stainless steel, embedded in cementitious material, corroded at a rate of <1 nm/year at 50°C.
- 29 July 2020
- Published by Wiley in Materials and Corrosion
- Vol. 72 (1-2) , 282-292
The anoxic corrosion behaviour of copper in the presence of chloride and sulphide
The Canadian used fuel container for the long‐term containment of spent nuclear fuel in a deep geological repository comprises a 3‐mm copper corrosion barrier applied directly to a strong carbon steel container. Although a final site for the Canadian deep geological repository has not yet been chosen, the site selection process has narrowed down to two candidate locations with unique groundwater chemistry, particularly with respect to salinity. Therefore, to ensure the long‐term integrity of the used fuel container, the effect of a range of groundwater chemistries on copper corrosion must be understood. The primary variables of interest are the influence of chloride concentration and the consequences of the interaction of hydrogen sulphide, naturally present in the groundwaters in very low concentrations, with the copper cladding. An additional aspect that has been investigated is the behaviour of copper in pure water. The anoxic corrosion of copper can be inferred by the very slow release of hydrogen gas. In this paper, new data are presented, which demonstrate an extremely sensitive approach to quantify the very limited hydrogen release at 75°C. Initially, corrosion rates under conditions approximating an anticipated Canadian deep geological repository were significantly less than 0.5 nm/year and they invariably declined over the course of several months/years. The presence of chloride or hydrogen sulphide was found, under specific conditions, to stimulate short‐term corrosion behaviour, which was consistent with anion‐assisted surface rearrangement, not bulk corrosion.
- 29 July 2020
- Published by Wiley in Materials and Corrosion
- Vol. 72 (1-2) , 282-292
The anoxic corrosion behaviour of copper in the presence of chloride and sulphide
The Canadian used fuel container for the long‐term containment of spent nuclear fuel in a deep geological repository comprises a 3‐mm copper corrosion barrier applied directly to a strong carbon steel container. Although a final site for the Canadian deep geological repository has not yet been chosen, the site selection process has narrowed down to two candidate locations with unique groundwater chemistry, particularly with respect to salinity. Therefore, to ensure the long‐term integrity of the used fuel container, the effect of a range of groundwater chemistries on copper corrosion must be understood. The primary variables of interest are the influence of chloride concentration and the consequences of the interaction of hydrogen sulphide, naturally present in the groundwaters in very low concentrations, with the copper cladding. An additional aspect that has been investigated is the behaviour of copper in pure water. The anoxic corrosion of copper can be inferred by the very slow release of hydrogen gas. In this paper, new data are presented, which demonstrate an extremely sensitive approach to quantify the very limited hydrogen release at 75°C. Initially, corrosion rates under conditions approximating an anticipated Canadian deep geological repository were significantly less than 0.5 nm/year and they invariably declined over the course of several months/years. The presence of chloride or hydrogen sulphide was found, under specific conditions, to stimulate short‐term corrosion behaviour, which was consistent with anion‐assisted surface rearrangement, not bulk corrosion.
- 29 June 2020
- Published by Wiley in Materials and Corrosion
- Vol. 72 (1-2) , 131-140
The anoxic corrosion behaviour of carbon steel in anoxic alkaline environments simulating a Swiss L/ILW repository environment
The Swiss waste management programme foresees that low‐ and intermediate‐level radioactive waste will be disposed of in a deep geological repository constructed in Opalinus Clay. Gas generation is expected in the repository due to the decomposition of organic materials and the corrosion of metals, with carbon steel being the primary source. The corrosion behaviour of mild steel under anoxic conditions has been studied over the course of several years to better understand the long‐term hydrogen evolution profile under anticipated repository conditions. Steel, either bare or encased within mortar, was tested in water vapour or immersed in electrolytes representative of aged cement waters at 50°C. The corrosion rate was measured indirectly through the hydrogen analysis using a solid‐state probe. The hydrogen evolution behaviour of grout was also monitored to more accurately determine the hydrogen generating from the corrosion of the embedded steel. For steel in water vapour or in alkaline environments, embedded in cementitious material or immersed in simulated aged cement pore water, corrosion rates were invariably <1 nm/year after several years of analysis.
- 29 June 2020
- Published by Wiley in Materials and Corrosion
- Vol. 72 (1-2) , 131-140
The anoxic corrosion behaviour of carbon steel in anoxic alkaline environments simulating a Swiss L/ILW repository environment
The Swiss waste management programme foresees that low‐ and intermediate‐level radioactive waste will be disposed of in a deep geological repository constructed in Opalinus Clay. Gas generation is expected in the repository due to the decomposition of organic materials and the corrosion of metals, with carbon steel being the primary source. The corrosion behaviour of mild steel under anoxic conditions has been studied over the course of several years to better understand the long‐term hydrogen evolution profile under anticipated repository conditions. Steel, either bare or encased within mortar, was tested in water vapour or immersed in electrolytes representative of aged cement waters at 50°C. The corrosion rate was measured indirectly through the hydrogen analysis using a solid‐state probe. The hydrogen evolution behaviour of grout was also monitored to more accurately determine the hydrogen generating from the corrosion of the embedded steel. For steel in water vapour or in alkaline environments, embedded in cementitious material or immersed in simulated aged cement pore water, corrosion rates were invariably <1 nm/year after several years of analysis.
- 5 June 2020
- Published by Wiley in Materials and Corrosion
- Vol. 72 (1-2) , 300-307
The nature of the copper sulfide film grown on copper in aqueous sulfide and chloride solutions
In this paper, the properties of copper sulfide films formed both anodically and naturally in deaerated/anoxic aqueous sulfide and chloride solutions were investigated using a series of electrochemical and surface analytical techniques. A combination of cyclic voltammetric, corrosion potential (Ecorr), and cathodic stripping voltammetric experiments showed that the sulfide film growth kinetics and film morphologies were controlled by the supply of SH− from the bulk solution to the copper surface. There was no passive barrier layer observed on the copper surface under either electrochemical or corrosion conditions. The film morphology was dependent on the type and concentration of anions (SH−, Cl−) present in the solution. Scanning electron microscopy on both surfaces and focused ion beam‐cut cross‐sections showed the growth of a thin, but porous, base layer of chalcocite (Cu2S) after short immersion periods (up to 2 hr) and the continuous growth of a much thicker crystalline outer deposit over longer immersion periods (≥36 hr), suggesting a solution species transport‐based film formation process and the formation of an ineffective thin “barrier‐type” layer on copper.
- 5 June 2020
- Published by Wiley in Materials and Corrosion
- Vol. 72 (1-2) , 300-307
The nature of the copper sulfide film grown on copper in aqueous sulfide and chloride solutions
In this paper, the properties of copper sulfide films formed both anodically and naturally in deaerated/anoxic aqueous sulfide and chloride solutions were investigated using a series of electrochemical and surface analytical techniques. A combination of cyclic voltammetric, corrosion potential (Ecorr), and cathodic stripping voltammetric experiments showed that the sulfide film growth kinetics and film morphologies were controlled by the supply of SH− from the bulk solution to the copper surface. There was no passive barrier layer observed on the copper surface under either electrochemical or corrosion conditions. The film morphology was dependent on the type and concentration of anions (SH−, Cl−) present in the solution. Scanning electron microscopy on both surfaces and focused ion beam‐cut cross‐sections showed the growth of a thin, but porous, base layer of chalcocite (Cu2S) after short immersion periods (up to 2 hr) and the continuous growth of a much thicker crystalline outer deposit over longer immersion periods (≥36 hr), suggesting a solution species transport‐based film formation process and the formation of an ineffective thin “barrier‐type” layer on copper.
- 1 January 2020
- Published by Elsevier in Electrochimica Acta
- Vol. 331
The effect of anions on the anodic formation of copper sulphide films on copper
- 1 January 2020
- Published by Elsevier in Electrochimica Acta
- Vol. 331
The effect of anions on the anodic formation of copper sulphide films on copper
- Open Access
- 6 November 2019
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 166 (15) , C550-C558
The Susceptibility of Copper to Pitting Corrosion in Borate-Buffered Aqueous Solutions Containing Chloride and Sulfide
The formation of sulfide and oxide films on copper (Cu) was studied in chloride solutions with and without added borate and sulfide. Electrochemical experiments demonstrated that Cu sulfide (Cu2S) films formed at considerably lower potentials than oxides (Cu2O/CuO) films. The growth of Cu2S was controlled by a combination of sulfide transport to the reacting Cu surface and the competition between SH− and Cl− ions for adsorption sites on the Cu surface. Scanning electron microscopy on focused ion-beam cut cross sections demonstrated that the films were porous and not passive. At more positive potentials, Raman spectroscopy and X-ray photoelectron spectroscopy demonstrated that the formation of oxide films, likely with the formation of a passive oxide film, dominated over anodic dissolution of Cu as CuI chloride complexes when the borate to chloride concentration ratio was sufficiently high. If pitting is to occur on Cu, it will require oxide not sulfide film growth.
- 6 November 2019
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 166 (15) , C550-C558
Open AccessThe Susceptibility of Copper to Pitting Corrosion in Borate-Buffered Aqueous Solutions Containing Chloride and Sulfide
The formation of sulfide and oxide films on copper (Cu) was studied in chloride solutions with and without added borate and sulfide. Electrochemical experiments demonstrated that Cu sulfide (Cu2S) films formed at considerably lower potentials than oxides (Cu2O/CuO) films. The growth of Cu2S was controlled by a combination of sulfide transport to the reacting Cu surface and the competition between SH− and Cl− ions for adsorption sites on the Cu surface. Scanning electron microscopy on focused ion-beam cut cross sections demonstrated that the films were porous and not passive. At more positive potentials, Raman spectroscopy and X-ray photoelectron spectroscopy demonstrated that the formation of oxide films, likely with the formation of a passive oxide film, dominated over anodic dissolution of Cu as CuI chloride complexes when the borate to chloride concentration ratio was sufficiently high. If pitting is to occur on Cu, it will require oxide not sulfide film growth.
- Open Access
- 10 June 2019
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 166 (10) , Y13-Y16
Comments on E. Huttunen-Saarivirta et al., “Kinetic Properties of the Passive Film on Copper in the Presence of Sulfate-Reducing Bacteria” [J. Electrochem. Soc., 165, C450 (2018)]
- 10 June 2019
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 166 (10) , Y13-Y16
Open AccessComments on E. Huttunen-Saarivirta et al., “Kinetic Properties of the Passive Film on Copper in the Presence of Sulfate-Reducing Bacteria” [J. Electrochem. Soc., 165, C450 (2018)]
- Open Access
- 9 January 2019
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 166 (2) , C9-C18
The Properties of Electrochemically-Grown Copper Sulfide Films
The electrochemical growth of copper sulfide films on copper has been studied voltammetrically and potentiostatically in 0.1 M sodium chloride solutions containing sulfide concentrations ranging from 10−4 M to 10−3 M. The properties of the films formed were investigated using electrochemical impedance spectroscopy. Film growth was observed to occur in two stages: the initial formation of a thin porous base layer at low potentials, followed by film restructuring leading to increased porosity and the deposition of an outer copper sulfide layer at more positive potentials. At more oxidizing potentials the overall film growth rate was determined by the properties of the outer deposit, not by the formation of a passive barrier layer at the Cu/film interface.
- 9 January 2019
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 166 (2) , C9-C18
Open AccessThe Properties of Electrochemically-Grown Copper Sulfide Films
The electrochemical growth of copper sulfide films on copper has been studied voltammetrically and potentiostatically in 0.1 M sodium chloride solutions containing sulfide concentrations ranging from 10−4 M to 10−3 M. The properties of the films formed were investigated using electrochemical impedance spectroscopy. Film growth was observed to occur in two stages: the initial formation of a thin porous base layer at low potentials, followed by film restructuring leading to increased porosity and the deposition of an outer copper sulfide layer at more positive potentials. At more oxidizing potentials the overall film growth rate was determined by the properties of the outer deposit, not by the formation of a passive barrier layer at the Cu/film interface.
- Open Access
- 28 April 2017
- Published by SAGE Publications in Corrosion Engineering, Science and Technology: The International Journal of Corrosion Processes and Corrosion Control
- Vol. 52 (sup1) , 61-64
The kinetics of film growth and their influence on the susceptibility to pitting of copper in aqueous sulphide solutions
The formation of copper sulphide films on copper in aqueous sulphide solutions has been investigated under both natural corrosion and electrochemical conditions. Film growth occurs at the Cu2S/electrolyte interface and involves Cu+ transport through a generally porous film. Both corrosion and anodic film growth are suppressed by high chloride concentrations. Passivity, a pre-requisite for pitting, is achievable only at high sulphide concentrations and transport fluxes, conditions not expected under most geologic repository conditions since both sulphide groundwater concentrations and diffusive transport rates are expected to be low. This paper is part of a supplement on the 6th International Workshop on Long-Term Prediction of Corrosion Damage in Nuclear Waste Systems.
- 28 April 2017
- Published by SAGE Publications in Corrosion Engineering, Science and Technology: The International Journal of Corrosion Processes and Corrosion Control
- Vol. 52 (sup1) , 61-64
Open AccessThe kinetics of film growth and their influence on the susceptibility to pitting of copper in aqueous sulphide solutions
The formation of copper sulphide films on copper in aqueous sulphide solutions has been investigated under both natural corrosion and electrochemical conditions. Film growth occurs at the Cu2S/electrolyte interface and involves Cu+ transport through a generally porous film. Both corrosion and anodic film growth are suppressed by high chloride concentrations. Passivity, a pre-requisite for pitting, is achievable only at high sulphide concentrations and transport fluxes, conditions not expected under most geologic repository conditions since both sulphide groundwater concentrations and diffusive transport rates are expected to be low. This paper is part of a supplement on the 6th International Workshop on Long-Term Prediction of Corrosion Damage in Nuclear Waste Systems.