NSNicholas A. Senior

Nicholas A. Senior

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nicholas A. Senior has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Characterization of the Corrosion of Copper Materials Exposed to Anoxic Gaseous Hydrogen Sulfide Environments

    by Benjamin D. C. Hackett, Kevin Daub, Jason D. Giallonardo, Mehran Behazin, Peter G. Keech, Nicholas A. Senior, Suraj Y. Persaud

    In this study, the corrosion behavior of electrodeposited and cold‐sprayed copper materials were systematically investigated under controlled exposure to hydrogen sulfide (H 2 S) gas in an inert atmosphere, with emphasis on the roles of surface condition, humidity, and exposure duration. In dry H 2 S, dense copper(I) sulfide films are formed with morphology largely independent of underlying copper microstructure, consistent with diffusion‐controlled growth. Pre‐oxidation delayed initial film formation, indicating slower oxide‐to‐sulfide conversion in the absence of a liquid electrolyte, though sulfide film thickness differences diminished over time. In contrast, humidity fundamentally altered corrosion behavior by introducing microscale aqueous environments via surface condensation. This led to localized corrosion features, including droplet‐induced structures and previously unreported hollow sulfide pillars governed by droplet geometry.

  • The Use of Low‐Cost Commercial Hydrogen Sensors for Thermal Desorption Research

    by Nicholas Senior, Taylor Martino, Nikitas Diomidis, Peter George Keech, Jason Giallonardo, Roberto Gaggiano, Christina Lilja, Erik Bergendal

    The corrosion of metallic materials under anoxic deep geological repository (DGR) conditions inevitably results in the evolution of hydrogen. From a research perspective, this hydrogen provides an approach to understanding the uniform corrosion rates of materials as well as the inventory of hydrogen that can accumulate within the repository. The corroding metals themselves are hydrogen sinks; thus, it is important to understand how much hydrogen is absorbed as a function of concentration, pH and temperature. For metallic packages that will contain highly hazardous nuclear waste, potential changes to mechanical properties due to hydrogen absorption must be understood. For experimental work supporting the safety of DGR science, absorption or desorption of hydrogen can impact the corrosion rate calculations, complicating safety assessments. To address these issues, a thermal desorption analyser has been developed to characterise materials used in corrosion experiments. The analyser is simple to construct and operate and yields excellent sensitivity using a commercially‐available hydrogen sensor. This article describes the design and capabilities of this analyser.

  • Open Access

    Characterization of Corrosion Products Formed from the Exposure of Cold Sprayed Copper to Anoxic Gaseous Hydrogen Sulfide

    by Benjamin Hackett, Kevin Daub, Jason D. Giallonardo, Nicholas Senior, Jeffrey D. Henderson, Mehran Behazin, Peter Keech, Suraj Persaud

    The corrosion of cold-sprayed copper was investigated in a gaseous mixture of 100 ppm H2S in dry N2. Both pristine and thermally pre-oxidized samples were exposed, and the resulting sulfide films were characterized using x-ray photoelectron spectroscopy and scanning electron microscopy. The films were all identified as copper(I) sulfide. No traces of oxide from the thermal pre-oxidation process were detectible through the film. Samples exposed for six-months exhibited surface platelets with altered chemistry; however, these features were attributed to post-exposure storage and are not representative of the as-formed corrosion products. The chemical conversion of oxide to sulfide on pre-oxidized samples was observed to be slower than sulfide formation on pristine surfaces. This behavior contrasts with the kinetics reported for similar oxide-sulfide interactions in equivalent aqueous environments and is likely due to differences in oxide-sulfide conversion mechanisms under gaseous conditions. These results advance the understanding of copper corrosion processes relevant to used fuel containers proposed for the long-term management of used nuclear fuel.

  • Open Access

    Materials Acceleration Platform for Electrochemistry: a Platform for Autonomous Electrochemistry

    by Daniel Persaud, Mike Werezak, Mark Xu, Melyne Zhou, Frank Benkel, Xin Pang, Vahid Attari, Brian DeCost, Ashley S. Dale, Nicholas Senior, et al.

    Corrosion testing is slow, labor-intensive, and sensitive to operator technique, limiting the generation of large, high-quality datasets for data-driven materials discovery. The Materials Acceleration Platform for Electrochemistry (MAP-E) is an autonomous, high-throughput system, capable of performing parallel electrochemical experiments. It integrates robotic liquid handling and sample transfer with a multi-channel potentiostatic control to extract corrosion metrics without human intervention. Validation against an ASTM G61-analog benchmark demonstrates good reproducibility, with a standard deviation of 75 mV in pitting potential across 32 automated measurements. The platform was then employed to autonomously construct pH-chloride stability diagrams for 304 stainless steel using an uncertainty-driven sampling strategy on a Gaussian process surrogate model. This approach reduces operator involvement and accelerates the exploration of environmental spaces. The MAP-E establishes a framework for autonomous electrochemical experimentation, enabling generation of corrosion datasets that inform materials discovery, alloy design, and durability assessment in service environments.


  • Corrosion Behavior of Unprotected Weldments in Marine Environments

    by Nicholas A. Senior, Lawrence Parkinson, Magdalene Matchim, Jennifer Collier, Hung-Wei Liu

    In the absence of protective measures such as paint or cathodic protection systems, steel weldments, immersed in seawater, are expected to corrode freely. This is particularly true for the ice breakers serving the Canadian Coast Guard, where, in the course of operations, paint is scoured from the vessel hulls and cathodic protection systems were not installed. However, the weldments do not corrode uniformly. In some cases, the weld itself corrodes rapidly and requires regular replacement. At the other extreme, the heat-affected zones (HAZ) corrode instead—a potential safety and integrity concern. The morphology of ice breaker weldment corrosion has altered over the last few decades and this has been attributed to changes in welding consumables and processes. The current study is an investigation into the corrosion characteristics of weldments with a particular focus on the compositional differences between weld metal and hull plate steels. A method has been developed for numerically describing the corrosion of weldment regions (plate steel, HAZ, weld cap passes, and weld re-heated zones) arising from an accelerated corrosion test. This in turn enabled the development of an equation that predicts weldment corrosion performance based entirely on material composition. This permits selection of welding consumables that are anticipated to give good corrosion performance, avoiding the extremes of rapid weld metal corrosion and preferential HAZ attack.


  • The corrosion of mild and stainless steel in alkaline anaerobic conditions representing the Belgian “supercontainer” concept and the Swiss L/ILW repository

    by Nicholas A. Senior, Taylor Martino, Roberto Gaggiano, Nikitas Diomidis

    Deep geological repositories for radioactive waste contain metallic materials, either used to construct disposal canisters or as low‐/intermediate‐level waste (L/ILW). The safety relevance of corrosion is linked to canister lifetime in the former case and gas generation in the latter. More specifically, the Belgian “supercontainer” concept envisages mild steel for the used fuel disposal canister, and in the case of the Swiss L/ILW repository, mild steels are the largest metallic waste component due to the decommissioning of civilian power‐generating facilities. For these circumstances, the corrosion environment is dominated by the chemistry of cement, which is used as buffer or backfill material. The corrosion behaviour of mild steel in anoxic environments was studied through the analysis of the hydrogen end‐product. Hydrogen analysis was conducted by periodically purging the cell head‐space and analysing the gas using a solid‐state hydrogen sensor. While this method is limited to providing only uniform corrosion rates averaged over periods of time, ranging from weeks to months, it provides excellent resolution and sensitivity. The test cell environments were matched against the anticipated Belgian high‐level waste and Swiss L/ILW repository environments, and also against experiments that have been conducted by other researchers for comparative purposes. Samples were exposed to synthetic cement pore waters, representing fresh and degraded cement. In young cement waters, the formation of initial corrosion products resulted in steel wire corrosion rates of the order of µm/year, which, at 80°C rapidly declined to ∼10 nm/year. In contrast, SA516 grade 70 steel plate corroded much more slowly under similar conditions. In aged cement waters, initial corrosion rates were higher but declined faster towards a longer‐term rate of ∼10 nm/year. 316L stainless steel, embedded in cementitious material, corroded at a rate of <1 nm/year at 50°C.


  • Overview of anaerobic corrosion of carbon steel radioactive waste packages in alkaline media in support of the Belgian supercontainer concept

    by Bruno Kursten, Nick R. Smart, Nicholas A. Senior, Digby D. Macdonald, Sébastien Caes, Valdir de Souza, Roberto Gaggiano

    The so‐called supercontainer concept is currently being considered as the reference design for the final disposal of vitrified high‐level radioactive waste and spent fuel in Belgium. It comprises a prefabricated Portland cement‐based buffer that completely surrounds a carbon steel overpack. In this highly alkaline environment (pH ~13.6), and under normal conditions (i.e., without the ingress of aggressive species), the carbon steel overpack will be protected by a passive oxide film, which is expected to result in very low uniform corrosion rates. Considering the long timescales applicable to waste disposal, determining accurate and reliable estimates of the uniform corrosion rate under anoxic conditions forms a very important part of the safety and feasibility strategy. It is also crucial to demonstrate that no other form of corrosion apart from uniform corrosion takes place. This paper presents the progress of the research that has been made since the LTC2016 Workshop (Toronto, Canada) on uniform corrosion, pitting corrosion and stress corrosion cracking behaviour of P355 QL2 grade carbon steel exposed to an artificial concrete pore water solution.


  • The anoxic corrosion behaviour of copper in the presence of chloride and sulphide

    by Nicholas A. Senior, Taylor Martino, Jeff Binns, Peter Keech

    The Canadian used fuel container for the long‐term containment of spent nuclear fuel in a deep geological repository comprises a 3‐mm copper corrosion barrier applied directly to a strong carbon steel container. Although a final site for the Canadian deep geological repository has not yet been chosen, the site selection process has narrowed down to two candidate locations with unique groundwater chemistry, particularly with respect to salinity. Therefore, to ensure the long‐term integrity of the used fuel container, the effect of a range of groundwater chemistries on copper corrosion must be understood. The primary variables of interest are the influence of chloride concentration and the consequences of the interaction of hydrogen sulphide, naturally present in the groundwaters in very low concentrations, with the copper cladding. An additional aspect that has been investigated is the behaviour of copper in pure water. The anoxic corrosion of copper can be inferred by the very slow release of hydrogen gas. In this paper, new data are presented, which demonstrate an extremely sensitive approach to quantify the very limited hydrogen release at 75°C. Initially, corrosion rates under conditions approximating an anticipated Canadian deep geological repository were significantly less than 0.5 nm/year and they invariably declined over the course of several months/years. The presence of chloride or hydrogen sulphide was found, under specific conditions, to stimulate short‐term corrosion behaviour, which was consistent with anion‐assisted surface rearrangement, not bulk corrosion.


  • The anoxic corrosion behaviour of carbon steel in anoxic alkaline environments simulating a Swiss L/ILW repository environment

    by Nicholas A. Senior, Taylor Martino, Nikitas Diomidis

    The Swiss waste management programme foresees that low‐ and intermediate‐level radioactive waste will be disposed of in a deep geological repository constructed in Opalinus Clay. Gas generation is expected in the repository due to the decomposition of organic materials and the corrosion of metals, with carbon steel being the primary source. The corrosion behaviour of mild steel under anoxic conditions has been studied over the course of several years to better understand the long‐term hydrogen evolution profile under anticipated repository conditions. Steel, either bare or encased within mortar, was tested in water vapour or immersed in electrolytes representative of aged cement waters at 50°C. The corrosion rate was measured indirectly through the hydrogen analysis using a solid‐state probe. The hydrogen evolution behaviour of grout was also monitored to more accurately determine the hydrogen generating from the corrosion of the embedded steel. For steel in water vapour or in alkaline environments, embedded in cementitious material or immersed in simulated aged cement pore water, corrosion rates were invariably <1 nm/year after several years of analysis.


  • Open Access

    Understanding and quantifying the anoxic corrosion of carbon steel in a Swiss L/ILW repository environment

    by Nick Senior, Roger Newman, Steve Wang, Nikitas Diomidis

    The anaerobic corrosion of steel was monitored under simulated Swiss low-/intermediate-level waste repository conditions. Steel was studied both as bare rods and cast in cement, in water vapour, simulating the unsaturated anoxic phase, and during immersion in various pore waters, representative of the saturated phase. All tests were performed at 50°C. Hydrogen evolution from grout, comprising commercial cement and sand, was also studied. Grouted steel specimens initially generated hydrogen that was comparable to grout alone, which was attributed to the presence of iron detritus from the ball-milling of cement clinker. The corrosion rate of immersed test specimens peaked during the first 100 days, likely due to the formation of a passive film. Corrosion rates generally declined to This paper is part of a supplement on the 6th International Workshop on Long-Term Prediction of Corrosion Damage in Nuclear Waste Systems.