Sean M. Delserro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Sean M. Delserro has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Patrick Smolinski
Shoulder and Elbow Mechanical Research Laboratory, Department of Orthopaedic Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania
3 shared publications - Christopher C. Schmidt
Department of Orthopaedic Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania
2 shared publications - Christopher D. Spicer
Department of Materials Department of Bioengineering and Institute of Biomedical Engineering Imperial College London London SW7 2AZ United Kingdom
2 shared publications - Mark Carl Miller
Departments of Mechanical Engineering & Materials Science and Bioengineering, University of Pittsburgh, 633 Benedum Hall, Pittsburgh, PA 16261, USA
2 shared publications - Michael P. Smolinski
Department of Mechanical Engineering and Material Science, University of Pittsburgh, Pittsburgh, PA, USA
2 shared publications - Yoshiaki Tomizuka
Department of Orthopaedic Surgery, Nihon University School of Medicine, Tokyo, Japan
2 shared publications
Latest Publications
- Open Access
- 27 April 2022
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 104 (14) , 1292-1300
The Rotator Cable Does Not Stress Shield the Crescent Area During Shoulder Abduction
Background: It is accepted by the orthopaedic community that the rotator cable (RCa) acts as a suspension bridge that stress shields the crescent area (CA). The goal of this study was to determine if the RCa does stress shield the CA during shoulder abduction. Methods: The principal strain magnitude and direction in the RCa and CA and shoulder abduction force were measured in 20 cadaveric specimens. Ten specimens underwent a release of the anterior cable insertion followed by a posterior release. In the other 10, a release of the posterior cable insertion was followed by an anterior release. Testing was performed for the native, single-release, and full-release conditions. The thicknesses of the RCa and CA were measured. Results: Neither the principal strain magnitude nor the strain direction in either the RCa or the CA changed with single or full RCa release (p ≥ 0.493). There were no changes in abduction force after single or full RCa release (p ≥ 0.180). The RCa and CA thicknesses did not differ from one another at any location (p ≥ 0.195). Conclusions: The RCa does not act as a suspension bridge and does not stress shield the CA. The CA primarily transfers shoulder abduction force to the greater tuberosity. Clinical Relevance: The CA is important in force transmission during shoulder abduction, and efforts should be made to restore its continuity with a repair or reconstruction.
- 27 April 2022
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 104 (14) , 1292-1300
Open AccessThe Rotator Cable Does Not Stress Shield the Crescent Area During Shoulder Abduction
Background: It is accepted by the orthopaedic community that the rotator cable (RCa) acts as a suspension bridge that stress shields the crescent area (CA). The goal of this study was to determine if the RCa does stress shield the CA during shoulder abduction. Methods: The principal strain magnitude and direction in the RCa and CA and shoulder abduction force were measured in 20 cadaveric specimens. Ten specimens underwent a release of the anterior cable insertion followed by a posterior release. In the other 10, a release of the posterior cable insertion was followed by an anterior release. Testing was performed for the native, single-release, and full-release conditions. The thicknesses of the RCa and CA were measured. Results: Neither the principal strain magnitude nor the strain direction in either the RCa or the CA changed with single or full RCa release (p ≥ 0.493). There were no changes in abduction force after single or full RCa release (p ≥ 0.180). The RCa and CA thicknesses did not differ from one another at any location (p ≥ 0.195). Conclusions: The RCa does not act as a suspension bridge and does not stress shield the CA. The CA primarily transfers shoulder abduction force to the greater tuberosity. Clinical Relevance: The CA is important in force transmission during shoulder abduction, and efforts should be made to restore its continuity with a repair or reconstruction.
- 25 January 2021
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 103 (9) , 812-819
Partial Distal Biceps Avulsion Results in a Significant Loss of Supination Force
Background: Partial avulsions of the short and/or long head of the distal biceps tendon cause pain and loss of strength. The goal of the present study was to quantify the loss of supination and flexion strength following a series of surgical releases designed to simulate partial and complete short and long head traumatic avulsions. Methods: Mechanical testing was performed to measure supination moment arms and flexion force efficiency on 18 adult fresh-frozen specimens in pronation, neutral, and supination. The distal biceps footprint length was divided into 4 equal segments. In 9 specimens (the distal-first group), the tendon was partially cut starting distally by releasing 25%, 50%, and 75% of the insertion site. In the other 9 specimens (the proximal-first group), the releases started proximally. Mechanical testing was performed before and after each release. Results: Significant decreases in the supination moment arm occurred after a 75% release in the distal-first release group; the decrease was 24% in pronation (p = 0.003) and 10% in neutral (p = 0.043). No significant differences in the supination moment arm (p ≥ 0.079) or in flexion force efficiency (p ≥ 0.058) occurred in the proximal-first group. Conclusions: A simulated complete short head avulsion significantly decreased the supination moment arm and therefore supination strength. Clinical Relevance: A mechanical case can be made for repair of partial distal biceps tendon avulsions when the rupture involves ≥75% of the distal insertion site.
- 25 January 2021
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 103 (9) , 812-819
Partial Distal Biceps Avulsion Results in a Significant Loss of Supination Force
Background: Partial avulsions of the short and/or long head of the distal biceps tendon cause pain and loss of strength. The goal of the present study was to quantify the loss of supination and flexion strength following a series of surgical releases designed to simulate partial and complete short and long head traumatic avulsions. Methods: Mechanical testing was performed to measure supination moment arms and flexion force efficiency on 18 adult fresh-frozen specimens in pronation, neutral, and supination. The distal biceps footprint length was divided into 4 equal segments. In 9 specimens (the distal-first group), the tendon was partially cut starting distally by releasing 25%, 50%, and 75% of the insertion site. In the other 9 specimens (the proximal-first group), the releases started proximally. Mechanical testing was performed before and after each release. Results: Significant decreases in the supination moment arm occurred after a 75% release in the distal-first release group; the decrease was 24% in pronation (p = 0.003) and 10% in neutral (p = 0.043). No significant differences in the supination moment arm (p ≥ 0.079) or in flexion force efficiency (p ≥ 0.058) occurred in the proximal-first group. Conclusions: A simulated complete short head avulsion significantly decreased the supination moment arm and therefore supination strength. Clinical Relevance: A mechanical case can be made for repair of partial distal biceps tendon avulsions when the rupture involves ≥75% of the distal insertion site.
- 22 January 2019
- Published by Morressier GmbH
1107 - Strain Shielding in Rotator Cuff with and without Rotator Cable
INTRODUCTION: The rotator cable (RCa), which originates at the coracohumeral ligament (CHL) insertion and terminates between the infraspinatus (I |
- 22 January 2019
- Published by Morressier GmbH
1107 - Strain Shielding in Rotator Cuff with and without Rotator Cable
INTRODUCTION: The rotator cable (RCa), which originates at the coracohumeral ligament (CHL) insertion and terminates between the infraspinatus (I |