Performance of the 0-Padding Optimal Filter Method in Non-Linear Gain Calibration
Authors:
- Michael C. WitthoeftMWMichael C. Witthoeft
- Stephen J. SmithSSStephen J. Smith
- Nicolás CardielNCNicolás Cardiel
- M. Teresa CeballosMCM. Teresa Ceballos
- Beatriz CoboBCBeatriz Cobo
- James A. ChervenakJCJames A. Chervenak
- Fred M. FinkbeinerFFFred M. Finkbeiner
- Joshua D. FuhrmanJFJoshua D. Fuhrman
- Samuel V. HullSHSamuel V. Hull
- 22 January 2025
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-6
Abstract
The focal-plane detector, the X-ray Integral Field Unit (X-IFU), on-board ESA's Athena space telescope is a transition edge sensor (TES) microcalorimeter array with 1.5 k pixels, designed to provide spatially-resolved, high-resolution spectroscopy over the energy range 0.2-12 keV. The onboard event processor uses a digital optimal filter to determine the pulse-height of the measured current pulse from every X-ray photon striking the array. A modified optimal filter called the 0-padding filter has recently been proposed. This is a truncated version of the standard optimal filter and has been shown to provide comparable energy resolution but with the benefit of reduced computational expense. Whereas the standard optimal filter has zero integral and is not sensitive to variations in the DC level of the measured signal, the integral of the 0-padded version is non-zero and thus is more sensitive to fluctuations in DC signal over time. In this work, we explore the effect of 0-padding on the energy scale calibration using data from 250-pixels in a prototype Athena X-IFU array, measured over the range 1.3-12 keV.Keywords
This publication has 12 references indexed in Scilit:
- Development of the microcalorimeter detector for the Athena/X-ray Integral Field Unit2024
- Advanced Energy Scale Correction Techniques for the X-ray Transition Edge Sensors of the Athena missionJournal of Low Temperature Physics, 2024
- The first cut is the cheapest: optimizing Athena/X-IFU-like TES detectors resolution by filter truncationExperimental Astronomy, 2024
- Correcting Gain Drift in TES Detectors for Future X-Ray Satellite MissionsIEEE Transactions on Applied Superconductivity, 2023
- The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phaseExperimental Astronomy, 2023
- Performance of a Broad-Band, High-Resolution, Transition-Edge Sensor Spectrometer for X-ray AstrophysicsIEEE Transactions on Applied Superconductivity, 2021
- Demonstration of Athena X-IFU Compatible 40-Row Time-Division-Multiplexed ReadoutIEEE Transactions on Applied Superconductivity, 2019
- Ground calibration of the Astro-H (Hitomi) soft x-ray spectrometerJournal of Astronomical Telescopes, Instruments, and Systems, 2018
- Temporal Gain Correction for X-ray Calorimeter SpectrometersJournal of Low Temperature Physics, 2016
- The Practice of Pulse ProcessingJournal of Low Temperature Physics, 2015