Beatriz Cobo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Beatriz Cobo has a total of 182 co-authors. Here are the top co-authors by number of shared publications:
- Maria Teresa Ceballos
Instituto de Física de Cantabria
9 shared publications - Didier Barret
Institut de Recherche en Astrophysique et Planétologie
5 shared publications - Joern Wilms
Dr. Karl Remeis-Sternwarte and Erlangen Centre for Astroparticle Physics, Friedrich-Alexander Universität Erlangen-Nürnberg
5 shared publications - Jelle de Plaa
SRON Netherlands Institute for Space Research
4 shared publications - Luigi Piro
INAF – Istituto di Astrofisica e Planetologia Spaziali
4 shared publications - Stephen James Smith
NASA Goddard Space Flight Center (GSFC), Greenbelt, MD, USA
4 shared publications
Latest Publications
- 22 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-6
Performance of the 0-Padding Optimal Filter Method in Non-Linear Gain Calibration
The focal-plane detector, the X-ray Integral Field Unit (X-IFU), on-board ESA's Athena space telescope is a transition edge sensor (TES) microcalorimeter array with 1.5 k pixels, designed to provide spatially-resolved, high-resolution spectroscopy over the energy range 0.2-12 keV. The onboard event processor uses a digital optimal filter to determine the pulse-height of the measured current pulse from every X-ray photon striking the array. A modified optimal filter called the 0-padding filter has recently been proposed. This is a truncated version of the standard optimal filter and has been shown to provide comparable energy resolution but with the benefit of reduced computational expense. Whereas the standard optimal filter has zero integral and is not sensitive to variations in the DC level of the measured signal, the integral of the 0-padded version is non-zero and thus is more sensitive to fluctuations in DC signal over time. In this work, we explore the effect of 0-padding on the energy scale calibration using data from 250-pixels in a prototype Athena X-IFU array, measured over the range 1.3-12 keV.
- 22 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-6
Performance of the 0-Padding Optimal Filter Method in Non-Linear Gain Calibration
The focal-plane detector, the X-ray Integral Field Unit (X-IFU), on-board ESA's Athena space telescope is a transition edge sensor (TES) microcalorimeter array with 1.5 k pixels, designed to provide spatially-resolved, high-resolution spectroscopy over the energy range 0.2-12 keV. The onboard event processor uses a digital optimal filter to determine the pulse-height of the measured current pulse from every X-ray photon striking the array. A modified optimal filter called the 0-padding filter has recently been proposed. This is a truncated version of the standard optimal filter and has been shown to provide comparable energy resolution but with the benefit of reduced computational expense. Whereas the standard optimal filter has zero integral and is not sensitive to variations in the DC level of the measured signal, the integral of the 0-padded version is non-zero and thus is more sensitive to fluctuations in DC signal over time. In this work, we explore the effect of 0-padding on the energy scale calibration using data from 250-pixels in a prototype Athena X-IFU array, measured over the range 1.3-12 keV.
- Open Access
The first cut is the cheapest: optimizing Athena/X-IFU-like TES detectors resolution by filter truncation
The X-ray Integral Field Unit (X-IFU) instrument on the future ESA mission Athena X-ray Observatory is a cryogenic micro-calorimeter array of Transition Edge Sensor (TES) detectors designed to provide spatially-resolved high-resolution spectroscopy. The onboard reconstruction software provides energy, spatial location and arrival time of incoming X-ray photons hitting the detector. A new processing algorithm based on a truncation of the classical optimal filter and called 0-padding, has been recently proposed aiming to reduce the computational cost without compromising energy resolution. Initial tests with simple synthetic data displayed promising results. This study explores the slightly better performance of the 0-padding filter and assess its final application to real data. The goal is to examine the larger sensitivity to instrumental conditions that was previously observed during the analysis of the simulations. This 0-padding technique is thoroughly tested using more realistic simulations and real data acquired from NASA and NIST laboratories employing X-IFU-like TES detectors. Different fitting methods are applied to the data, and a comparative analysis is performed to assess the energy resolution values obtained from these fittings. The 0-padding filter achieves energy resolutions as good as those obtained with standard filters, even with those of larger lengths, across different line complexes and instrumental conditions. This method proves to be useful for energy reconstruction of X-ray photons detected by the TES detectors provided proper corrections for baseline drift and jitter effects are applied. The finding is highly promising especially for onboard processing, offering efficiency in computational resources and facilitating the analysis of sources with higher count rates at high resolution.
Open AccessThe first cut is the cheapest: optimizing Athena/X-IFU-like TES detectors resolution by filter truncation
The X-ray Integral Field Unit (X-IFU) instrument on the future ESA mission Athena X-ray Observatory is a cryogenic micro-calorimeter array of Transition Edge Sensor (TES) detectors designed to provide spatially-resolved high-resolution spectroscopy. The onboard reconstruction software provides energy, spatial location and arrival time of incoming X-ray photons hitting the detector. A new processing algorithm based on a truncation of the classical optimal filter and called 0-padding, has been recently proposed aiming to reduce the computational cost without compromising energy resolution. Initial tests with simple synthetic data displayed promising results. This study explores the slightly better performance of the 0-padding filter and assess its final application to real data. The goal is to examine the larger sensitivity to instrumental conditions that was previously observed during the analysis of the simulations. This 0-padding technique is thoroughly tested using more realistic simulations and real data acquired from NASA and NIST laboratories employing X-IFU-like TES detectors. Different fitting methods are applied to the data, and a comparative analysis is performed to assess the energy resolution values obtained from these fittings. The 0-padding filter achieves energy resolutions as good as those obtained with standard filters, even with those of larger lengths, across different line complexes and instrumental conditions. This method proves to be useful for energy reconstruction of X-ray photons detected by the TES detectors provided proper corrections for baseline drift and jitter effects are applied. The finding is highly promising especially for onboard processing, offering efficiency in computational resources and facilitating the analysis of sources with higher count rates at high resolution.
- Open Access
- 21 March 2024
- Published by Springer Nature in Experimental Astronomy
- Vol. 57 (2) , 1-46
The first cut is the cheapest: optimizing Athena/X-IFU-like TES detectors resolution by filter truncation
The X-ray Integral Field Unit (X-IFU) instrument on the future ESA mission Athena X-ray Observatory is a cryogenic micro-calorimeter array of Transition Edge Sensor (TES) detectors designed to provide spatially-resolved high-resolution spectroscopy. The onboard reconstruction software provides energy, spatial location and arrival time of incoming X-ray photons hitting the detector. A new processing algorithm based on a truncation of the classical optimal filter and called 0-padding, has been recently proposed aiming to reduce the computational cost without compromising energy resolution. Initial tests with simple synthetic data displayed promising results. This study explores the slightly better performance of the 0-padding filter and assess its final application to real data. The goal is to examine the larger sensitivity to instrumental conditions that was previously observed during the analysis of the simulations. This 0-padding technique is thoroughly tested using more realistic simulations and real data acquired from NASA and NIST laboratories employing X-IFU-like TES detectors. Different fitting methods are applied to the data, and a comparative analysis is performed to assess the energy resolution values obtained from these fittings. The 0-padding filter achieves energy resolutions as good as those obtained with standard filters, even with those of larger lengths, across different line complexes and instrumental conditions. This method proves to be useful for energy reconstruction of X-ray photons detected by the TES detectors provided proper corrections for baseline drift and jitter effects are applied. The finding is highly promising especially for onboard processing, offering efficiency in computational resources and facilitating the analysis of sources with higher count rates at high resolution.
- 21 March 2024
- Published by Springer Nature in Experimental Astronomy
- Vol. 57 (2) , 1-46
Open AccessThe first cut is the cheapest: optimizing Athena/X-IFU-like TES detectors resolution by filter truncation
The X-ray Integral Field Unit (X-IFU) instrument on the future ESA mission Athena X-ray Observatory is a cryogenic micro-calorimeter array of Transition Edge Sensor (TES) detectors designed to provide spatially-resolved high-resolution spectroscopy. The onboard reconstruction software provides energy, spatial location and arrival time of incoming X-ray photons hitting the detector. A new processing algorithm based on a truncation of the classical optimal filter and called 0-padding, has been recently proposed aiming to reduce the computational cost without compromising energy resolution. Initial tests with simple synthetic data displayed promising results. This study explores the slightly better performance of the 0-padding filter and assess its final application to real data. The goal is to examine the larger sensitivity to instrumental conditions that was previously observed during the analysis of the simulations. This 0-padding technique is thoroughly tested using more realistic simulations and real data acquired from NASA and NIST laboratories employing X-IFU-like TES detectors. Different fitting methods are applied to the data, and a comparative analysis is performed to assess the energy resolution values obtained from these fittings. The 0-padding filter achieves energy resolutions as good as those obtained with standard filters, even with those of larger lengths, across different line complexes and instrumental conditions. This method proves to be useful for energy reconstruction of X-ray photons detected by the TES detectors provided proper corrections for baseline drift and jitter effects are applied. The finding is highly promising especially for onboard processing, offering efficiency in computational resources and facilitating the analysis of sources with higher count rates at high resolution.
- Open Access
- 24 January 2023
- Published by International Organization Center of Academic Research
TEACHING SAMPLING TECHNIQUES USING R AND PYTHON
- 24 January 2023
- Published by International Organization Center of Academic Research
Open AccessTEACHING SAMPLING TECHNIQUES USING R AND PYTHON
- Open Access
- 1 February 2022
- Published by IOP Publishing in Publications of the Astronomical Society of the Pacific
- Vol. 134 (1032) , 024504
Event Detection and Reconstruction Using Neural Networks in TES Devices: a Case Study for Athena/X-IFU
Transition Edge Sensors detector devices, like the core of the X-IFU instrument that will be on-board the Athena X-ray Observatory, produce current pulses as a response to the incident X-ray photons. The reconstruction of these pulses has been traditionally performed by means of a triggering algorithm based on the derivative signal overcoming a threshold (detection) followed by an optimal filtering (to retrieve the energy of each event). However, when the arrival of the photons is very close in time, the triggering algorithm is incapable of detecting all the individual pulses which are thus piled-up. In order to improve the efficiency of the detection and energy-retrieval process, we study here an alternative approach based on Machine Learning techniques to process the pulses. For this purpose, we construct and train a series of Neural Networks (NNs) not only for the detection but also for the recovering of the arrival time and the energy of simulated X-ray pulses. The data set used to train the NNs consists of simulations performed with the sixte/xifusim software package, the Athena/X-IFU official simulator. The performance of our NN classification clearly surpasses the detection performance of the classical triggering approach for the full range of photon energy combinations, showing excellent metrics and very competitive computing efficiency. However, the precision obtained for the recovery of the energy of the photons cannot currently compete with the standard optimal filtering algorithm, despite its much better computing efficiency.
- 1 February 2022
- Published by IOP Publishing in Publications of the Astronomical Society of the Pacific
- Vol. 134 (1032) , 024504
Open AccessEvent Detection and Reconstruction Using Neural Networks in TES Devices: a Case Study for Athena/X-IFU
Transition Edge Sensors detector devices, like the core of the X-IFU instrument that will be on-board the Athena X-ray Observatory, produce current pulses as a response to the incident X-ray photons. The reconstruction of these pulses has been traditionally performed by means of a triggering algorithm based on the derivative signal overcoming a threshold (detection) followed by an optimal filtering (to retrieve the energy of each event). However, when the arrival of the photons is very close in time, the triggering algorithm is incapable of detecting all the individual pulses which are thus piled-up. In order to improve the efficiency of the detection and energy-retrieval process, we study here an alternative approach based on Machine Learning techniques to process the pulses. For this purpose, we construct and train a series of Neural Networks (NNs) not only for the detection but also for the recovering of the arrival time and the energy of simulated X-ray pulses. The data set used to train the NNs consists of simulations performed with the sixte/xifusim software package, the Athena/X-IFU official simulator. The performance of our NN classification clearly surpasses the detection performance of the classical triggering approach for the full range of photon energy combinations, showing excellent metrics and very competitive computing efficiency. However, the precision obtained for the recovery of the energy of the photons cannot currently compete with the standard optimal filtering algorithm, despite its much better computing efficiency.
- 17 August 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9905, 99052F
The Athena X-ray Integral Field Unit (X-IFU)
The X-ray Integral Field Unit (X-IFU) on board the Advanced Telescope for High-ENergy Astrophysics (Athena) will provide spatially resolved high-resolution X-ray spectroscopy from 0.2 to 12 keV, with ~ 5" pixels over a field of view of 5 arc minute equivalent diameter and a spectral resolution of 2.5 eV up to 7 keV. In this paper, we first review the core scientific objectives of Athena, driving the main performance parameters of the X-IFU, namely the spectral resolution, the field of view, the effective area, the count rate capabilities, the instrumental background. We also illustrate the breakthrough potential of the X-IFU for some observatory science goals. Then we brie y describe the X-IFU design as defined at the time of the mission consolidation review concluded in May 2016, and report on its predicted performance. Finally, we discuss some options to improve the instrument performance while not increasing its complexity and resource demands (e.g. count rate capability, spectral resolution).
- 17 August 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9905, 99052F
The Athena X-ray Integral Field Unit (X-IFU)
The X-ray Integral Field Unit (X-IFU) on board the Advanced Telescope for High-ENergy Astrophysics (Athena) will provide spatially resolved high-resolution X-ray spectroscopy from 0.2 to 12 keV, with ~ 5" pixels over a field of view of 5 arc minute equivalent diameter and a spectral resolution of 2.5 eV up to 7 keV. In this paper, we first review the core scientific objectives of Athena, driving the main performance parameters of the X-IFU, namely the spectral resolution, the field of view, the effective area, the count rate capabilities, the instrumental background. We also illustrate the breakthrough potential of the X-IFU for some observatory science goals. Then we brie y describe the X-IFU design as defined at the time of the mission consolidation review concluded in May 2016, and report on its predicted performance. Finally, we discuss some options to improve the instrument performance while not increasing its complexity and resource demands (e.g. count rate capability, spectral resolution).
- 19 July 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9905, 990564-990564-7
TESSIM: a simulator for the Athena-X-IFU
- 19 July 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9905, 990564-990564-7
TESSIM: a simulator for the Athena-X-IFU
- 18 July 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9905, 99055F
Observing the WHIM with Athena
We present simulations of the detection probability for absorption lines from ions in the warm and hot ionized medium (WHIM) with Athena in the spectra of Gamma-ray burst afterglows. The simulations are based on Swift XRT lightcurves of these afterglows and are performed using the end-to-end simulation framework SIXTE. We simulate both the case of single and multiple absorption lines, as well as results for line searches in absorption structures from a more complex medium. We show that the Athena X-IFU can detect WHIM lines with strong Ovii lines (equivalent widths larger than 0.14 eV) in spectra containing 3 x 106 counts.
- 18 July 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9905, 99055F
Observing the WHIM with Athena
We present simulations of the detection probability for absorption lines from ions in the warm and hot ionized medium (WHIM) with Athena in the spectra of Gamma-ray burst afterglows. The simulations are based on Swift XRT lightcurves of these afterglows and are performed using the end-to-end simulation framework SIXTE. We simulate both the case of single and multiple absorption lines, as well as results for line searches in absorption structures from a more complex medium. We show that the Athena X-IFU can detect WHIM lines with strong Ovii lines (equivalent widths larger than 0.14 eV) in spectra containing 3 x 106 counts.
- 11 July 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9905, 99055W
Performance assessment of different pulse reconstruction algorithms for the ATHENA X-ray Integral Field Unit
The X-ray Integral Field Unit (X-IFU) microcalorimeter, on-board Athena, with its focal plane comprising 3840 Transition Edge Sensors (TESs) operating at 90 mK, will provide unprecedented spectral-imaging capability in the 0.2-12 keV energy range. It will rely on the on-board digital processing of current pulses induced by the heat deposited in the TES absorber, as to recover the energy of each individual events. Assessing the capabilities of the pulse reconstruction is required to understand the overall scientific performance of the X-IFU, notably in terms of energy resolution degradation with both increasing energies and count rates. Using synthetic data streams generated by the X-IFU End-to-End simulator, we present here a comprehensive benchmark of various pulse reconstruction techniques, ranging from standard optimal filtering to more advanced algorithms based on noise covariance matrices. Beside deriving the spectral resolution achieved by the different algorithms, a first assessment of the computing power and ground calibration needs is presented. Overall, all methods show similar performances, with the reconstruction based on noise covariance matrices showing the best improvement with respect to the standard optimal filtering technique. Due to prohibitive calibration needs, this method might however not be applicable to the X-IFU and the best compromise currently appears to be the so-called resistance space analysis which also features very promising high count rate capabilities.
- 11 July 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9905, 99055W
Performance assessment of different pulse reconstruction algorithms for the ATHENA X-ray Integral Field Unit
The X-ray Integral Field Unit (X-IFU) microcalorimeter, on-board Athena, with its focal plane comprising 3840 Transition Edge Sensors (TESs) operating at 90 mK, will provide unprecedented spectral-imaging capability in the 0.2-12 keV energy range. It will rely on the on-board digital processing of current pulses induced by the heat deposited in the TES absorber, as to recover the energy of each individual events. Assessing the capabilities of the pulse reconstruction is required to understand the overall scientific performance of the X-IFU, notably in terms of energy resolution degradation with both increasing energies and count rates. Using synthetic data streams generated by the X-IFU End-to-End simulator, we present here a comprehensive benchmark of various pulse reconstruction techniques, ranging from standard optimal filtering to more advanced algorithms based on noise covariance matrices. Beside deriving the spectral resolution achieved by the different algorithms, a first assessment of the computing power and ground calibration needs is presented. Overall, all methods show similar performances, with the reconstruction based on noise covariance matrices showing the best improvement with respect to the standard optimal filtering technique. Due to prohibitive calibration needs, this method might however not be applicable to the X-IFU and the best compromise currently appears to be the so-called resistance space analysis which also features very promising high count rate capabilities.