Maria Teresa Ceballos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Maria Teresa Ceballos has a total of 607 co-authors. Here are the top co-authors by number of shared publications:
- Francisco J. Carrera
Instituto de Fisica de Cantabria (CSIC-Universidad de Cantabria), Avenida de los Castros
32 shared publications - Xavier Barcons
Instituto de Fisica de Cantabria (Spain)
30 shared publications - Silvia Mateos
Instituto de Física de Cantabria (CSIC-Universidad de Cantabria)
18 shared publications - Didier Barret
Institut de Recherche en Astrophysique et Planétologie
12 shared publications - Luigi Piro
INAF – Istituto di Astrofisica e Planetologia Spaziali
10 shared publications - Beatriz Cobo
Instituto de Fisica de Cantabria (Spain)
9 shared publications
Latest Publications
- 23 July 2026
- Published by Santander. Estudios de Patrimonio. Editorial de la Universidad de Cantabria
Ciencia de película. La hormiga que soñaba con agujeros negros
¿Qué buscas cuando vas al cine? Que no te quepa duda, buscas emocionarte. Y no importa si vas a ver una película de terror, una comedia romántica, o una película de acción con explosiones. TODAS (con mayúsculas) las películas transmiten emociones, que pueden ir desde el miedo, la tristeza y el aburrimiento, hasta la sorpresa o la alegría. Si ahora te digo que todas las películas tienen ciencia, es muy probable que tu primer pensamiento sea «todas, todas… igual no». TODAS. Créeme. En El Padrino podemos hablar —por ejemplo— de la ciencia en las armas de fuego, o de la biología de los gatos. En Cantando bajo la lluvia, una película musical, tenemos para elegir entre las ondas sonoras y el ciclo del agua. ¿Titanic? Anda que no hay ciencia en un barco... o en el iceberg que lo hundió. Hasta en Ratatouille encontramos ciencia entre los fogones. El cine es un medio fantástico para descubrir cosas que desconocemos, para ver conexiones que nunca nos habríamos planteado. Así, en cada capítulo de este libro partimos de una película para contar un relato sobre la ciencia a la que nos dedicamos. Las películas elegidas son La ventana indiscreta (1954), Contact (1997), Her (2013), Interstellar (2014), Big Hero 6 (2014), Ant-Man (2015), Figuras ocultas (2016), y Tenet (2020). Disfruta.
- 23 July 2026
- Published by Santander. Estudios de Patrimonio. Editorial de la Universidad de Cantabria
Ciencia de película. La hormiga que soñaba con agujeros negros
¿Qué buscas cuando vas al cine? Que no te quepa duda, buscas emocionarte. Y no importa si vas a ver una película de terror, una comedia romántica, o una película de acción con explosiones. TODAS (con mayúsculas) las películas transmiten emociones, que pueden ir desde el miedo, la tristeza y el aburrimiento, hasta la sorpresa o la alegría. Si ahora te digo que todas las películas tienen ciencia, es muy probable que tu primer pensamiento sea «todas, todas… igual no». TODAS. Créeme. En El Padrino podemos hablar —por ejemplo— de la ciencia en las armas de fuego, o de la biología de los gatos. En Cantando bajo la lluvia, una película musical, tenemos para elegir entre las ondas sonoras y el ciclo del agua. ¿Titanic? Anda que no hay ciencia en un barco... o en el iceberg que lo hundió. Hasta en Ratatouille encontramos ciencia entre los fogones. El cine es un medio fantástico para descubrir cosas que desconocemos, para ver conexiones que nunca nos habríamos planteado. Así, en cada capítulo de este libro partimos de una película para contar un relato sobre la ciencia a la que nos dedicamos. Las películas elegidas son La ventana indiscreta (1954), Contact (1997), Her (2013), Interstellar (2014), Big Hero 6 (2014), Ant-Man (2015), Figuras ocultas (2016), y Tenet (2020). Disfruta.
- 22 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-6
Performance of the 0-Padding Optimal Filter Method in Non-Linear Gain Calibration
The focal-plane detector, the X-ray Integral Field Unit (X-IFU), on-board ESA's Athena space telescope is a transition edge sensor (TES) microcalorimeter array with 1.5 k pixels, designed to provide spatially-resolved, high-resolution spectroscopy over the energy range 0.2-12 keV. The onboard event processor uses a digital optimal filter to determine the pulse-height of the measured current pulse from every X-ray photon striking the array. A modified optimal filter called the 0-padding filter has recently been proposed. This is a truncated version of the standard optimal filter and has been shown to provide comparable energy resolution but with the benefit of reduced computational expense. Whereas the standard optimal filter has zero integral and is not sensitive to variations in the DC level of the measured signal, the integral of the 0-padded version is non-zero and thus is more sensitive to fluctuations in DC signal over time. In this work, we explore the effect of 0-padding on the energy scale calibration using data from 250-pixels in a prototype Athena X-IFU array, measured over the range 1.3-12 keV.
- 22 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-6
Performance of the 0-Padding Optimal Filter Method in Non-Linear Gain Calibration
The focal-plane detector, the X-ray Integral Field Unit (X-IFU), on-board ESA's Athena space telescope is a transition edge sensor (TES) microcalorimeter array with 1.5 k pixels, designed to provide spatially-resolved, high-resolution spectroscopy over the energy range 0.2-12 keV. The onboard event processor uses a digital optimal filter to determine the pulse-height of the measured current pulse from every X-ray photon striking the array. A modified optimal filter called the 0-padding filter has recently been proposed. This is a truncated version of the standard optimal filter and has been shown to provide comparable energy resolution but with the benefit of reduced computational expense. Whereas the standard optimal filter has zero integral and is not sensitive to variations in the DC level of the measured signal, the integral of the 0-padded version is non-zero and thus is more sensitive to fluctuations in DC signal over time. In this work, we explore the effect of 0-padding on the energy scale calibration using data from 250-pixels in a prototype Athena X-IFU array, measured over the range 1.3-12 keV.
- Open Access
The first cut is the cheapest: optimizing Athena/X-IFU-like TES detectors resolution by filter truncation
The X-ray Integral Field Unit (X-IFU) instrument on the future ESA mission Athena X-ray Observatory is a cryogenic micro-calorimeter array of Transition Edge Sensor (TES) detectors designed to provide spatially-resolved high-resolution spectroscopy. The onboard reconstruction software provides energy, spatial location and arrival time of incoming X-ray photons hitting the detector. A new processing algorithm based on a truncation of the classical optimal filter and called 0-padding, has been recently proposed aiming to reduce the computational cost without compromising energy resolution. Initial tests with simple synthetic data displayed promising results. This study explores the slightly better performance of the 0-padding filter and assess its final application to real data. The goal is to examine the larger sensitivity to instrumental conditions that was previously observed during the analysis of the simulations. This 0-padding technique is thoroughly tested using more realistic simulations and real data acquired from NASA and NIST laboratories employing X-IFU-like TES detectors. Different fitting methods are applied to the data, and a comparative analysis is performed to assess the energy resolution values obtained from these fittings. The 0-padding filter achieves energy resolutions as good as those obtained with standard filters, even with those of larger lengths, across different line complexes and instrumental conditions. This method proves to be useful for energy reconstruction of X-ray photons detected by the TES detectors provided proper corrections for baseline drift and jitter effects are applied. The finding is highly promising especially for onboard processing, offering efficiency in computational resources and facilitating the analysis of sources with higher count rates at high resolution.
Open AccessThe first cut is the cheapest: optimizing Athena/X-IFU-like TES detectors resolution by filter truncation
The X-ray Integral Field Unit (X-IFU) instrument on the future ESA mission Athena X-ray Observatory is a cryogenic micro-calorimeter array of Transition Edge Sensor (TES) detectors designed to provide spatially-resolved high-resolution spectroscopy. The onboard reconstruction software provides energy, spatial location and arrival time of incoming X-ray photons hitting the detector. A new processing algorithm based on a truncation of the classical optimal filter and called 0-padding, has been recently proposed aiming to reduce the computational cost without compromising energy resolution. Initial tests with simple synthetic data displayed promising results. This study explores the slightly better performance of the 0-padding filter and assess its final application to real data. The goal is to examine the larger sensitivity to instrumental conditions that was previously observed during the analysis of the simulations. This 0-padding technique is thoroughly tested using more realistic simulations and real data acquired from NASA and NIST laboratories employing X-IFU-like TES detectors. Different fitting methods are applied to the data, and a comparative analysis is performed to assess the energy resolution values obtained from these fittings. The 0-padding filter achieves energy resolutions as good as those obtained with standard filters, even with those of larger lengths, across different line complexes and instrumental conditions. This method proves to be useful for energy reconstruction of X-ray photons detected by the TES detectors provided proper corrections for baseline drift and jitter effects are applied. The finding is highly promising especially for onboard processing, offering efficiency in computational resources and facilitating the analysis of sources with higher count rates at high resolution.
- Open Access
- 21 March 2024
- Published by Springer Nature in Experimental Astronomy
- Vol. 57 (2) , 1-46
The first cut is the cheapest: optimizing Athena/X-IFU-like TES detectors resolution by filter truncation
The X-ray Integral Field Unit (X-IFU) instrument on the future ESA mission Athena X-ray Observatory is a cryogenic micro-calorimeter array of Transition Edge Sensor (TES) detectors designed to provide spatially-resolved high-resolution spectroscopy. The onboard reconstruction software provides energy, spatial location and arrival time of incoming X-ray photons hitting the detector. A new processing algorithm based on a truncation of the classical optimal filter and called 0-padding, has been recently proposed aiming to reduce the computational cost without compromising energy resolution. Initial tests with simple synthetic data displayed promising results. This study explores the slightly better performance of the 0-padding filter and assess its final application to real data. The goal is to examine the larger sensitivity to instrumental conditions that was previously observed during the analysis of the simulations. This 0-padding technique is thoroughly tested using more realistic simulations and real data acquired from NASA and NIST laboratories employing X-IFU-like TES detectors. Different fitting methods are applied to the data, and a comparative analysis is performed to assess the energy resolution values obtained from these fittings. The 0-padding filter achieves energy resolutions as good as those obtained with standard filters, even with those of larger lengths, across different line complexes and instrumental conditions. This method proves to be useful for energy reconstruction of X-ray photons detected by the TES detectors provided proper corrections for baseline drift and jitter effects are applied. The finding is highly promising especially for onboard processing, offering efficiency in computational resources and facilitating the analysis of sources with higher count rates at high resolution.
- 21 March 2024
- Published by Springer Nature in Experimental Astronomy
- Vol. 57 (2) , 1-46
Open AccessThe first cut is the cheapest: optimizing Athena/X-IFU-like TES detectors resolution by filter truncation
The X-ray Integral Field Unit (X-IFU) instrument on the future ESA mission Athena X-ray Observatory is a cryogenic micro-calorimeter array of Transition Edge Sensor (TES) detectors designed to provide spatially-resolved high-resolution spectroscopy. The onboard reconstruction software provides energy, spatial location and arrival time of incoming X-ray photons hitting the detector. A new processing algorithm based on a truncation of the classical optimal filter and called 0-padding, has been recently proposed aiming to reduce the computational cost without compromising energy resolution. Initial tests with simple synthetic data displayed promising results. This study explores the slightly better performance of the 0-padding filter and assess its final application to real data. The goal is to examine the larger sensitivity to instrumental conditions that was previously observed during the analysis of the simulations. This 0-padding technique is thoroughly tested using more realistic simulations and real data acquired from NASA and NIST laboratories employing X-IFU-like TES detectors. Different fitting methods are applied to the data, and a comparative analysis is performed to assess the energy resolution values obtained from these fittings. The 0-padding filter achieves energy resolutions as good as those obtained with standard filters, even with those of larger lengths, across different line complexes and instrumental conditions. This method proves to be useful for energy reconstruction of X-ray photons detected by the TES detectors provided proper corrections for baseline drift and jitter effects are applied. The finding is highly promising especially for onboard processing, offering efficiency in computational resources and facilitating the analysis of sources with higher count rates at high resolution.
- 15 April 2019
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 624, A77
The XMM-Newton serendipitous survey
Context. XMM-Newton has observed the X-ray sky since early 2000. The XMM-Newton Survey Science Centre Consortium has published catalogues of X-ray and ultraviolet sources found serendipitously in the individual observations. This series is now augmented by a catalogue dedicated to X-ray sources detected in spatially overlapping XMM-Newton observations. Aims. The aim of this catalogue is to explore repeatedly observed sky regions. It thus makes use of the long(er) effective exposure time per sky area and offers the opportunity to investigate long-term flux variability directly through the source-detection process. Methods. A new standardised strategy for simultaneous source detection on multiple observations was introduced, including an adaptive-smoothing method to describe the image background. It was coded as a new task within the XMM-Newton Science Analysis System and used to compile a catalogue of sources from 434 stacks comprising 1789 overlapping XMM-Newton observations that entered the 3XMM-DR7 catalogue, have a low background and full-frame readout of all EPIC cameras. Results. The first stacked catalogue is called 3XMM-DR7s. It contains 71 951 unique sources with positions and parameters such as fluxes, hardness ratios, quality estimates, and information on inter-observation variability, directly derived from a simultaneous fit. Source parameters are calculated for the stack and for each contributing observation. About 15% of the sources are new with respect to 3XMM-DR7. Through stacked source detection, the parameters of repeatedly observed sources are determined with higher accuracy than in the individual observations. The method is more sensitive to faint sources and tends to produce fewer spurious detections. Conclusions. With this first stacked catalogue we demonstrate the feasibility and benefit of the approach. It supplements the large data base of XMM-Newton detections with additional, in particular faint, sources and adds variability information. In the future, the catalogue will be expanded to larger samples and continued within the series of serendipitous XMM-Newton source catalogues.
- 15 April 2019
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 624, A77
The XMM-Newton serendipitous survey
Context. XMM-Newton has observed the X-ray sky since early 2000. The XMM-Newton Survey Science Centre Consortium has published catalogues of X-ray and ultraviolet sources found serendipitously in the individual observations. This series is now augmented by a catalogue dedicated to X-ray sources detected in spatially overlapping XMM-Newton observations. Aims. The aim of this catalogue is to explore repeatedly observed sky regions. It thus makes use of the long(er) effective exposure time per sky area and offers the opportunity to investigate long-term flux variability directly through the source-detection process. Methods. A new standardised strategy for simultaneous source detection on multiple observations was introduced, including an adaptive-smoothing method to describe the image background. It was coded as a new task within the XMM-Newton Science Analysis System and used to compile a catalogue of sources from 434 stacks comprising 1789 overlapping XMM-Newton observations that entered the 3XMM-DR7 catalogue, have a low background and full-frame readout of all EPIC cameras. Results. The first stacked catalogue is called 3XMM-DR7s. It contains 71 951 unique sources with positions and parameters such as fluxes, hardness ratios, quality estimates, and information on inter-observation variability, directly derived from a simultaneous fit. Source parameters are calculated for the stack and for each contributing observation. About 15% of the sources are new with respect to 3XMM-DR7. Through stacked source detection, the parameters of repeatedly observed sources are determined with higher accuracy than in the individual observations. The method is more sensitive to faint sources and tends to produce fewer spurious detections. Conclusions. With this first stacked catalogue we demonstrate the feasibility and benefit of the approach. It supplements the large data base of XMM-Newton detections with additional, in particular faint, sources and adds variability information. In the future, the catalogue will be expanded to larger samples and continued within the series of serendipitous XMM-Newton source catalogues.
- 31 July 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10699, 51
The ATHENA x-ray integral field unit (X-IFU)
The X-ray Integral Field Unit (X-IFU) is the high resolution X-ray spectrometer of the ESA Athena X-ray observatory. Over a field of view of 5’ equivalent diameter, it will deliver X-ray spectra from 0.2 to 12 keV with a spectral resolution of 2.5 eV up to 7 keV on ∼ 5” pixels. The X-IFU is based on a large format array of super-conducting molybdenum-gold Transition Edge Sensors cooled at ∼ 90 mK, each coupled with an absorber made of gold and bismuth with a pitch of 249 μm. A cryogenic anti-coincidence detector located underneath the prime TES array enables the non X-ray background to be reduced. A bath temperature of ∼ 50 mK is obtained by a series of mechanical coolers combining 15K Pulse Tubes, 4K and 2K Joule-Thomson coolers which pre-cool a sub Kelvin cooler made of a 3He sorption cooler coupled with an Adiabatic Demagnetization Refrigerator. Frequency domain multiplexing enables to read out 40 pixels in one single channel. A photon interacting with an absorber leads to a current pulse, amplified by the readout electronics and whose shape is reconstructed on board to recover its energy with high accuracy. The defocusing capability offered by the Athena movable mirror assembly enables the X-IFU to observe the brightest X-ray sources of the sky (up to Crab-like intensities) by spreading the telescope point spread function over hundreds of pixels. Thus the X-IFU delivers low pile-up, high throughput (< 50%), and typically 10 eV spectral resolution at 1 Crab intensities, i.e. a factor of 10 or more better than Silicon based X-ray detectors. In this paper, the current X-IFU baseline is presented, together with an assessment of its anticipated performance in terms of spectral resolution, background, and count rate capability. The X-IFU baseline configuration will be subject to a preliminary requirement review that is scheduled at the end of 2018.
- 31 July 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10699, 51
The ATHENA x-ray integral field unit (X-IFU)
The X-ray Integral Field Unit (X-IFU) is the high resolution X-ray spectrometer of the ESA Athena X-ray observatory. Over a field of view of 5’ equivalent diameter, it will deliver X-ray spectra from 0.2 to 12 keV with a spectral resolution of 2.5 eV up to 7 keV on ∼ 5” pixels. The X-IFU is based on a large format array of super-conducting molybdenum-gold Transition Edge Sensors cooled at ∼ 90 mK, each coupled with an absorber made of gold and bismuth with a pitch of 249 μm. A cryogenic anti-coincidence detector located underneath the prime TES array enables the non X-ray background to be reduced. A bath temperature of ∼ 50 mK is obtained by a series of mechanical coolers combining 15K Pulse Tubes, 4K and 2K Joule-Thomson coolers which pre-cool a sub Kelvin cooler made of a 3He sorption cooler coupled with an Adiabatic Demagnetization Refrigerator. Frequency domain multiplexing enables to read out 40 pixels in one single channel. A photon interacting with an absorber leads to a current pulse, amplified by the readout electronics and whose shape is reconstructed on board to recover its energy with high accuracy. The defocusing capability offered by the Athena movable mirror assembly enables the X-IFU to observe the brightest X-ray sources of the sky (up to Crab-like intensities) by spreading the telescope point spread function over hundreds of pixels. Thus the X-IFU delivers low pile-up, high throughput (< 50%), and typically 10 eV spectral resolution at 1 Crab intensities, i.e. a factor of 10 or more better than Silicon based X-ray detectors. In this paper, the current X-IFU baseline is presented, together with an assessment of its anticipated performance in terms of spectral resolution, background, and count rate capability. The X-IFU baseline configuration will be subject to a preliminary requirement review that is scheduled at the end of 2018.
- 6 July 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10699, 169
ATHENA X-ray Integral Field Unit on-board event processor: analysis of performance of two triggering algorithms
In the framework of the ESA Athena mission, the X-ray Integral Field Unit (X-IFU) micro-calorimeter will provide unprecedented spatially resolved high-resolution X-ray spectroscopy. For this purpose, the on-board Event Processor (EP) must initially trigger the current pulses induced by the X-ray photons hitting the detector to proceed with a reconstruction which provides the arrival time, spatial location and energy of each event. The current event triggering design is implemented in two stages: one initial trigger of the low-pass filtered derivative of the raw data to extract records containing pulses and a second stage performing a fine detection to look for all the pulses in the record. In order to establish the current baseline detection technique of the EP in the X-IFU instrument, an assessment of the capabilities of different triggering algorithms is required, both in terms of performance (detection efficiency) and computational load, as processing will take place on-board. We present a comparison of two detection algorithms, the Simplest Threshold Crossing (STC) and the model-dependent Adjusted Derivative (AD). The analysis also evaluates the (possible) negative effect of different instrumental scenarios as a reduced sampling rate. The evaluations point out that the simplest algorithm STC shows worse performance than AD for the smallest pulses separations and the lowest secondary energies. Nevertheless, checking the expected number of such pulses combinations in a typical bright source observation, we conclude that it does not have impact in the science. Moreover, the savings in the computational resources and calibration needs make STC a valuable option.
- 6 July 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10699, 169
ATHENA X-ray Integral Field Unit on-board event processor: analysis of performance of two triggering algorithms
In the framework of the ESA Athena mission, the X-ray Integral Field Unit (X-IFU) micro-calorimeter will provide unprecedented spatially resolved high-resolution X-ray spectroscopy. For this purpose, the on-board Event Processor (EP) must initially trigger the current pulses induced by the X-ray photons hitting the detector to proceed with a reconstruction which provides the arrival time, spatial location and energy of each event. The current event triggering design is implemented in two stages: one initial trigger of the low-pass filtered derivative of the raw data to extract records containing pulses and a second stage performing a fine detection to look for all the pulses in the record. In order to establish the current baseline detection technique of the EP in the X-IFU instrument, an assessment of the capabilities of different triggering algorithms is required, both in terms of performance (detection efficiency) and computational load, as processing will take place on-board. We present a comparison of two detection algorithms, the Simplest Threshold Crossing (STC) and the model-dependent Adjusted Derivative (AD). The analysis also evaluates the (possible) negative effect of different instrumental scenarios as a reduced sampling rate. The evaluations point out that the simplest algorithm STC shows worse performance than AD for the smallest pulses separations and the lowest secondary energies. Nevertheless, checking the expected number of such pulses combinations in a typical bright source observation, we conclude that it does not have impact in the science. Moreover, the savings in the computational resources and calibration needs make STC a valuable option.
- Open Access
- 8 October 2016
- Published by Oxford University Press (OUP) in Monthly Notices of the Royal Astronomical Society
- Vol. 464 (4) , 4586-4592
X-ray-selected broad absorption line quasi-stellar objects
We study a sample of six X-ray-selected broad absorption line (BAL) quasi-stellar objects (QSOs) from the XMM–Newton Wide Angle Survey. All six objects are classified as BALQSOs using the classic balnicity index, and together they form the largest sample of X-ray-selected BALQSOs. We find evidence for absorption in the X-ray spectra of all six objects. An ionized absorption model applied to an X-ray spectral shape that would be typical for non-BAL QSOs (a power law with energy index α = 0.98) provides acceptable fits to the X-ray spectra of all six objects. The optical to X-ray spectral indices, αOX, of the X-ray-selected BALQSOs, have a mean value of 〈αOX〉 = 1.69 ± 0.05, which is similar to that found for X-ray-selected and optically selected non-BAL QSOs of a similar ultraviolet luminosity. In contrast, optically selected BALQSOs typically have much larger αOX and so are characterized as being X-ray weak. The results imply that X-ray selection yields intrinsically X-ray bright BALQSOs, but their X-ray spectra are absorbed by a similar degree to that seen in optically selected BALQSO samples; X-ray absorption appears to be ubiquitous in BALQSOs, but X-ray weakness is not. We argue that BALQSOs sit at one end of a spectrum of X-ray absorption properties in QSOs related to the degree of ultraviolet absorption in C iv 1550 Å.
- 8 October 2016
- Published by Oxford University Press (OUP) in Monthly Notices of the Royal Astronomical Society
- Vol. 464 (4) , 4586-4592
Open AccessX-ray-selected broad absorption line quasi-stellar objects
We study a sample of six X-ray-selected broad absorption line (BAL) quasi-stellar objects (QSOs) from the XMM–Newton Wide Angle Survey. All six objects are classified as BALQSOs using the classic balnicity index, and together they form the largest sample of X-ray-selected BALQSOs. We find evidence for absorption in the X-ray spectra of all six objects. An ionized absorption model applied to an X-ray spectral shape that would be typical for non-BAL QSOs (a power law with energy index α = 0.98) provides acceptable fits to the X-ray spectra of all six objects. The optical to X-ray spectral indices, αOX, of the X-ray-selected BALQSOs, have a mean value of 〈αOX〉 = 1.69 ± 0.05, which is similar to that found for X-ray-selected and optically selected non-BAL QSOs of a similar ultraviolet luminosity. In contrast, optically selected BALQSOs typically have much larger αOX and so are characterized as being X-ray weak. The results imply that X-ray selection yields intrinsically X-ray bright BALQSOs, but their X-ray spectra are absorbed by a similar degree to that seen in optically selected BALQSO samples; X-ray absorption appears to be ubiquitous in BALQSOs, but X-ray weakness is not. We argue that BALQSOs sit at one end of a spectrum of X-ray absorption properties in QSOs related to the degree of ultraviolet absorption in C iv 1550 Å.
- 17 August 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9905, 99052F
The Athena X-ray Integral Field Unit (X-IFU)
The X-ray Integral Field Unit (X-IFU) on board the Advanced Telescope for High-ENergy Astrophysics (Athena) will provide spatially resolved high-resolution X-ray spectroscopy from 0.2 to 12 keV, with ~ 5" pixels over a field of view of 5 arc minute equivalent diameter and a spectral resolution of 2.5 eV up to 7 keV. In this paper, we first review the core scientific objectives of Athena, driving the main performance parameters of the X-IFU, namely the spectral resolution, the field of view, the effective area, the count rate capabilities, the instrumental background. We also illustrate the breakthrough potential of the X-IFU for some observatory science goals. Then we brie y describe the X-IFU design as defined at the time of the mission consolidation review concluded in May 2016, and report on its predicted performance. Finally, we discuss some options to improve the instrument performance while not increasing its complexity and resource demands (e.g. count rate capability, spectral resolution).
- 17 August 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9905, 99052F
The Athena X-ray Integral Field Unit (X-IFU)
The X-ray Integral Field Unit (X-IFU) on board the Advanced Telescope for High-ENergy Astrophysics (Athena) will provide spatially resolved high-resolution X-ray spectroscopy from 0.2 to 12 keV, with ~ 5" pixels over a field of view of 5 arc minute equivalent diameter and a spectral resolution of 2.5 eV up to 7 keV. In this paper, we first review the core scientific objectives of Athena, driving the main performance parameters of the X-IFU, namely the spectral resolution, the field of view, the effective area, the count rate capabilities, the instrumental background. We also illustrate the breakthrough potential of the X-IFU for some observatory science goals. Then we brie y describe the X-IFU design as defined at the time of the mission consolidation review concluded in May 2016, and report on its predicted performance. Finally, we discuss some options to improve the instrument performance while not increasing its complexity and resource demands (e.g. count rate capability, spectral resolution).