Optimal Insertion Torque for Orthodontic Anchoring Screw Placement: A Comprehensive Review
Open Access
- 26 September 2023
- journal article
- review article
- Published by MDPI AG in Applied Sciences
- Vol. 13 (19) , 10681
Abstract
The optimal insertion torque (IT) for orthodontic anchoring screws (OASs) was hypothesized to vary with OAS features and insertion methods. This review examines the indexed English literature, to determine the appropriate IT range for OAS success based on area of insertion and OAS features. Eleven original articles with OAS placement in humans including IT and success rate were selected and were used to evaluate the relationships among IT, success rates, screw design, and placement methods at different sites. The ITs and success rates ranged from 6.0 ± 3.2 to 15.7 ± 2.3 Ncm and from 62.5 to 100.0% in the upper and lower buccal alveolar areas, respectively. For the mid-palatal area, the range was 14.5 ± 1.6 to 25.6 ± 5.5 Ncm and 83.0 to 100.0%, respectively. ITs of 5–12 and 6–14 Ncm were found to be optimal for the commonly used φ1.5–1.7 mm OASs in the upper and lower interproximal areas, respectively. In the mid-palatal suture area, ITs of 11–16 and 20–25 Ncm were considered suitable for tapered φ1.5 mm and φ2.0 mm OASs, respectively. Although identified optimal IT ranges deserve the recommendations, care must be taken to monitor the IT during placement constantly.Keywords
This publication has 32 references indexed in Scilit:
- Effects of screw and host factors on insertion torque and pullout strengthThe Angle Orthodontist, 2012
- Analysis of stress in bone and microimplants during en-masse retraction of maxillary and mandibular anterior teeth with different insertion angulations: A 3-dimensional finite element analysis studyAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2012
- Placement and removal torque values of orthodontic miniscrew implantsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2011
- Horizontal Pull-Out Strength of Orthodontic Infrazygomatic Mini-Implant: An In Vitro StudyImplant Dentistry, 2011
- Fracture resistance of orthodontic mini-implants: a biomechanical in vitro studyEuropean Journal of Orthodontics, 2011
- Mechanical strength of orthodontic infrazygomatic mini-implantsOdontology, 2011
- Mechanical properties of self-drilling orthodontic micro-implants with different diametersThe Angle Orthodontist, 2010
- Midpalatal miniscrews for orthodontic anchorage: Factors affecting clinical successAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2010
- Which region of the median palate is a suitable location of temporary orthodontic anchorage devices? A histomorphometric study on human cadavers aged 15–20 yearsClinical Oral Implants Research, 2009
- Application of orthodontic mini-implants in adolescentsInternational Journal of Oral and Maxillofacial Surgery, 2007