Yasuhiro Namura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yasuhiro Namura has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
Noriyoshi Shimizu
Department of Orthodontics, Nihon University School of Dentistry
11 shared publicationsMitsuru Motoyoshi
Department of Orthodontics, Nihon University School of Dentistry
6 shared publications- Mitsuru Motoyoshi
Department of Orthodontics, Nihon University School of Dentistry, Tokyo 101-8310, Japan
6 shared publications - Mizuki Inaba
Nihon University School of Dentistry, Department of Orthodontics, Tokyo, Japan
4 shared publications Takashi Tsuruoka
Department of Orthodontics, Nihon University School of Dentistry
4 shared publicationsTakayuki Yoneyama
Department of Dental Materials, Nihon University School of Dentistry
4 shared publications
Latest Publications
- Open Access
- 30 June 2026
- Published by Galenos Yayinevi in Turkish Journal of Orthodontics
- Vol. 39 (2) , 87-94
Effect on Bracket Bonding of Polishing with Fluoride-Containing Prophy Paste Before Enamel Pretreatment with Orthophosphoric Acid: A Randomized Clinical Trial
This randomized clinical trial assessed the effects of polishing enamel with fluoride prophy paste before enamel pretreatment with orthophosphoric acid on bracket bond outcomes. The study included 49 patients with a mean age of 24.6 years. Participants were randomly allocated to two groups in an approximate 1:1 ratio: 25 participants in the fluoride group (Group 1) and 24 in the non-fluoride group (Group 2). All patients’ tooth surfaces were polished with prophy paste, etched, and fitted with brackets. Patients were followed up for 6 months. Outcome measures included bracket bond survival and the number of bond failures, along with questionnaire items collected from all subjects, such as history of fluoride varnish and mouthwash use, age, and sex. Survival time analysis was used to characterize bond failure outcomes. A total of 951 brackets were tested; the overall bond failure rate was 2.7%. Group 2 (non-fluoride polishing) had a bond failure rate of 4.0%, while Group 1 (fluoride polishing) had a significantly lower failure rate of 1.5%. These failure rates were much lower than those reported previously. Survival analysis, accounting for patient-level variability through random effects, revealed that age and fluoride prophy paste were significant risk factors. The hazard ratio for bond failure associated with the use of fluoride-containing prophy paste was 0.26. Polishing with fluoride-containing prophy paste did not affect the bracket-bond failure rate when it was followed by phosphoric acid etching.
- 30 June 2026
- Published by Galenos Yayinevi in Turkish Journal of Orthodontics
- Vol. 39 (2) , 87-94
Open AccessEffect on Bracket Bonding of Polishing with Fluoride-Containing Prophy Paste Before Enamel Pretreatment with Orthophosphoric Acid: A Randomized Clinical Trial
This randomized clinical trial assessed the effects of polishing enamel with fluoride prophy paste before enamel pretreatment with orthophosphoric acid on bracket bond outcomes. The study included 49 patients with a mean age of 24.6 years. Participants were randomly allocated to two groups in an approximate 1:1 ratio: 25 participants in the fluoride group (Group 1) and 24 in the non-fluoride group (Group 2). All patients’ tooth surfaces were polished with prophy paste, etched, and fitted with brackets. Patients were followed up for 6 months. Outcome measures included bracket bond survival and the number of bond failures, along with questionnaire items collected from all subjects, such as history of fluoride varnish and mouthwash use, age, and sex. Survival time analysis was used to characterize bond failure outcomes. A total of 951 brackets were tested; the overall bond failure rate was 2.7%. Group 2 (non-fluoride polishing) had a bond failure rate of 4.0%, while Group 1 (fluoride polishing) had a significantly lower failure rate of 1.5%. These failure rates were much lower than those reported previously. Survival analysis, accounting for patient-level variability through random effects, revealed that age and fluoride prophy paste were significant risk factors. The hazard ratio for bond failure associated with the use of fluoride-containing prophy paste was 0.26. Polishing with fluoride-containing prophy paste did not affect the bracket-bond failure rate when it was followed by phosphoric acid etching.
- Open Access
- 1 January 2026
- Published by Nihon University School of Dentistry in Journal of Oral Science
- Vol. 68 (4) , 250-254
Effect of surface treatments and adhesive materials on the shear bond strength of PET-G aligner material
Purpose: To evaluate the effects of surface treatments and adhesive materials on the shear bond strength to a polyethylene glycol-co-cyclohexane-1,4-dimethanol terephthalate (PET-G) clear aligner material.Methods: PET-G specimens were randomly assigned to eight non-factorial groups (n = 11 per group). Transbond XT, LC Orthomite, and Super-Bond were evaluated without pretreatment and after alumina abrasion; Transbond XT was additionally tested with primer alone and with alumina abrasion plus primer. Shear bond strength was measured at 0.5 mm/min. Failure modes and debonded surfaces were examined by stereomicroscopy and field-emission scanning electron microscopy (FE-SEM). Data were analyzed using the Kruskal-Wallis and Steel-Dwass tests (α = 0.05).Results: Super-Bond showed significantly higher bond strength (25.1-27.0 MPa) than Transbond XT and LC Orthomite under untreated and alumina-abraded conditions. For Transbond XT, alumina abrasion, primer, and their combination significantly increased bond strength. Alumina abrasion also significantly increased LC Orthomite bond strength. Adhesive failure predominated in low-strength groups, whereas cohesive failure within PET-G or mixed failure was frequent in high-strength groups.Conclusion: Under the present conditions, Super-Bond showed high initial bond strength without pretreatment. Primer application and alumina abrasion improved Transbond XT bond strength, whereas alumina abrasion improved LC Orthomite bond strength.
- 1 January 2026
- Published by Nihon University School of Dentistry in Journal of Oral Science
- Vol. 68 (4) , 250-254
Open AccessEffect of surface treatments and adhesive materials on the shear bond strength of PET-G aligner material
Purpose: To evaluate the effects of surface treatments and adhesive materials on the shear bond strength to a polyethylene glycol-co-cyclohexane-1,4-dimethanol terephthalate (PET-G) clear aligner material.Methods: PET-G specimens were randomly assigned to eight non-factorial groups (n = 11 per group). Transbond XT, LC Orthomite, and Super-Bond were evaluated without pretreatment and after alumina abrasion; Transbond XT was additionally tested with primer alone and with alumina abrasion plus primer. Shear bond strength was measured at 0.5 mm/min. Failure modes and debonded surfaces were examined by stereomicroscopy and field-emission scanning electron microscopy (FE-SEM). Data were analyzed using the Kruskal-Wallis and Steel-Dwass tests (α = 0.05).Results: Super-Bond showed significantly higher bond strength (25.1-27.0 MPa) than Transbond XT and LC Orthomite under untreated and alumina-abraded conditions. For Transbond XT, alumina abrasion, primer, and their combination significantly increased bond strength. Alumina abrasion also significantly increased LC Orthomite bond strength. Adhesive failure predominated in low-strength groups, whereas cohesive failure within PET-G or mixed failure was frequent in high-strength groups.Conclusion: Under the present conditions, Super-Bond showed high initial bond strength without pretreatment. Primer application and alumina abrasion improved Transbond XT bond strength, whereas alumina abrasion improved LC Orthomite bond strength.
- Open Access
- 9 October 2025
- Published by Elsevier in Cell Stress and Chaperones
- Vol. 30 (6) , 100125
Allyl isothiocyanate suppresses the growth and pathogenicity of Candida albicans
- 9 October 2025
- Published by Elsevier in Cell Stress and Chaperones
- Vol. 30 (6) , 100125
Open AccessAllyl isothiocyanate suppresses the growth and pathogenicity of Candida albicans
- Open Access
- 3 July 2025
- Published by Taylor & Francis in Clinical and Investigative Orthodontics
- Vol. 84 (3) , 206-214
Finite element analysis of the critical stress for bone resorption around the orthodontic anchoring screw in midpalatal area during distalization of the maxillary dental arch
- 3 July 2025
- Published by Taylor & Francis in Clinical and Investigative Orthodontics
- Vol. 84 (3) , 206-214
Open AccessFinite element analysis of the critical stress for bone resorption around the orthodontic anchoring screw in midpalatal area during distalization of the maxillary dental arch
- Open Access
- 25 March 2024
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 43 (2) , 247-254
Changes in enamel hardness, wear resistance, surface texture, and surface crystal structure with glass ionomer cement containing BioUnion fillers
This study investigated the potential of BioUnion filler containing glass ionomer cement (GIC) to enhance the properties of enamel surrounding restorations, with a specific focus on the effect on hardness. The hardness of the bovine enamel immersed in the cement was measured using Vickers hardness numbers. Following sliding and impact wear simulations, the enamel facets were examined using confocal-laser-scanning microscopy and scanning-electron microscopy. Surface properties were further analyzed using energy-dispersive X-ray spectroscopy and X-ray diffraction (XRD). A significant increase in Vickers hardness numbers was observed in the BioUnion filler GIC after 2 days. Furthermore, the mean depth of enamel facets treated with BioUnion filler GIC was significantly less than that of untreated facets. Characteristic XRD peaks indicating the presence of hydroxyapatite were also observed. Our findings imply that GIC with BioUnion fillers enhances the mechanical properties of the tooth surface adjacent to the cement.
- 25 March 2024
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 43 (2) , 247-254
Open AccessChanges in enamel hardness, wear resistance, surface texture, and surface crystal structure with glass ionomer cement containing BioUnion fillers
This study investigated the potential of BioUnion filler containing glass ionomer cement (GIC) to enhance the properties of enamel surrounding restorations, with a specific focus on the effect on hardness. The hardness of the bovine enamel immersed in the cement was measured using Vickers hardness numbers. Following sliding and impact wear simulations, the enamel facets were examined using confocal-laser-scanning microscopy and scanning-electron microscopy. Surface properties were further analyzed using energy-dispersive X-ray spectroscopy and X-ray diffraction (XRD). A significant increase in Vickers hardness numbers was observed in the BioUnion filler GIC after 2 days. Furthermore, the mean depth of enamel facets treated with BioUnion filler GIC was significantly less than that of untreated facets. Characteristic XRD peaks indicating the presence of hydroxyapatite were also observed. Our findings imply that GIC with BioUnion fillers enhances the mechanical properties of the tooth surface adjacent to the cement.
- Open Access
- 1 January 2024
- Published by Nihon University School of Dentistry in Journal of Oral Science
- Vol. 66 (2) , 107-110
Elemental composition, corrosion resistance and mechanical properties of computer-aided design and computer-aided manufacturing fixed retainers versus conventional fixed retainers
Purpose: To investigate the elemental composition, corrosion resistance, and mechanical properties of computer-aided design and computer-aided manufacturing (CAD-CAM) retainers versus conventional fixed retainers (FRs).Methods: Eight different retainer wires were investigated. Energy dispersive X-ray spectroscopy was used to determine the elemental composition. Leakage was analysed according to ISO 10271:2020 guidelines. Hardness was tested using the Vickers method with a load of 0.3 kg. The tensile force and tensile strength were evaluated. Multiple comparisons among wires of hardness, tensile force, and strength were conducted using the Welch t-test, with Bonferroni correction.Results: Nickel was present in all wires. The CAD-CAM-FR wire, which contained more nickel than the other wires, had no measurable leakage. The gold-plated wires had the highest total leakage, but did not exceed the ISO standard limit. The hardness of the stainless-steel twisted wires was the highest and that of the CAD-CAM-FR wire was the lowest. The tensile strength of the CAD-CAM-FR wire was significantly lower than that of the other wires and similar to the other twisted-wire retainers.Conclusion: The CAD-CAM-FR wire is likely to have high corrosion resistance and flexibility due to its low hardness.
- 1 January 2024
- Published by Nihon University School of Dentistry in Journal of Oral Science
- Vol. 66 (2) , 107-110
Open AccessElemental composition, corrosion resistance and mechanical properties of computer-aided design and computer-aided manufacturing fixed retainers versus conventional fixed retainers
Purpose: To investigate the elemental composition, corrosion resistance, and mechanical properties of computer-aided design and computer-aided manufacturing (CAD-CAM) retainers versus conventional fixed retainers (FRs).Methods: Eight different retainer wires were investigated. Energy dispersive X-ray spectroscopy was used to determine the elemental composition. Leakage was analysed according to ISO 10271:2020 guidelines. Hardness was tested using the Vickers method with a load of 0.3 kg. The tensile force and tensile strength were evaluated. Multiple comparisons among wires of hardness, tensile force, and strength were conducted using the Welch t-test, with Bonferroni correction.Results: Nickel was present in all wires. The CAD-CAM-FR wire, which contained more nickel than the other wires, had no measurable leakage. The gold-plated wires had the highest total leakage, but did not exceed the ISO standard limit. The hardness of the stainless-steel twisted wires was the highest and that of the CAD-CAM-FR wire was the lowest. The tensile strength of the CAD-CAM-FR wire was significantly lower than that of the other wires and similar to the other twisted-wire retainers.Conclusion: The CAD-CAM-FR wire is likely to have high corrosion resistance and flexibility due to its low hardness.
- Open Access
- 26 September 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (19) , 10681
Optimal Insertion Torque for Orthodontic Anchoring Screw Placement: A Comprehensive Review
The optimal insertion torque (IT) for orthodontic anchoring screws (OASs) was hypothesized to vary with OAS features and insertion methods. This review examines the indexed English literature, to determine the appropriate IT range for OAS success based on area of insertion and OAS features. Eleven original articles with OAS placement in humans including IT and success rate were selected and were used to evaluate the relationships among IT, success rates, screw design, and placement methods at different sites. The ITs and success rates ranged from 6.0 ± 3.2 to 15.7 ± 2.3 Ncm and from 62.5 to 100.0% in the upper and lower buccal alveolar areas, respectively. For the mid-palatal area, the range was 14.5 ± 1.6 to 25.6 ± 5.5 Ncm and 83.0 to 100.0%, respectively. ITs of 5–12 and 6–14 Ncm were found to be optimal for the commonly used φ1.5–1.7 mm OASs in the upper and lower interproximal areas, respectively. In the mid-palatal suture area, ITs of 11–16 and 20–25 Ncm were considered suitable for tapered φ1.5 mm and φ2.0 mm OASs, respectively. Although identified optimal IT ranges deserve the recommendations, care must be taken to monitor the IT during placement constantly.
- 26 September 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (19) , 10681
Open AccessOptimal Insertion Torque for Orthodontic Anchoring Screw Placement: A Comprehensive Review
The optimal insertion torque (IT) for orthodontic anchoring screws (OASs) was hypothesized to vary with OAS features and insertion methods. This review examines the indexed English literature, to determine the appropriate IT range for OAS success based on area of insertion and OAS features. Eleven original articles with OAS placement in humans including IT and success rate were selected and were used to evaluate the relationships among IT, success rates, screw design, and placement methods at different sites. The ITs and success rates ranged from 6.0 ± 3.2 to 15.7 ± 2.3 Ncm and from 62.5 to 100.0% in the upper and lower buccal alveolar areas, respectively. For the mid-palatal area, the range was 14.5 ± 1.6 to 25.6 ± 5.5 Ncm and 83.0 to 100.0%, respectively. ITs of 5–12 and 6–14 Ncm were found to be optimal for the commonly used φ1.5–1.7 mm OASs in the upper and lower interproximal areas, respectively. In the mid-palatal suture area, ITs of 11–16 and 20–25 Ncm were considered suitable for tapered φ1.5 mm and φ2.0 mm OASs, respectively. Although identified optimal IT ranges deserve the recommendations, care must be taken to monitor the IT during placement constantly.
- 17 January 2022
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 161 (6) , 809-819
Age dependence of the maturation of the midpalatal suture in the stability of orthodontic anchoring screws
- 17 January 2022
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 161 (6) , 809-819
Age dependence of the maturation of the midpalatal suture in the stability of orthodontic anchoring screws
- 21 October 2021
- Published by Wiley in European Journal of Oral Sciences
- Vol. 130 (1) , e12831
Influence of masticating cycles and chewing patterns on inadvertent enamel wear caused by zirconia brackets
Little information is available about enamel wear caused by zirconia brackets, an inadvertent side effect of orthodontic treatment. The purpose of this study was to examine potential enamel damage induced by contact with zirconia brackets. Sliding and impact wear simulations were performed using bovine enamel specimens positioned at a 25° slant to a zirconium ball to determine wear behaviour. Different chewing patterns, tapping and grinding, were simulated. Specimens were profiled using confocal laser scanning microscopy, and the mean maximum depth and surface roughness were measured. Scanning electron microscopy was also performed. The mean maximum depth of wear values differed according to the number of mastication cycles, with a higher number of cycles producing higher depths of wear. The facet wear depth was significantly greater with the tapping pattern than with the grinding pattern. Scanning electron microscopic observation of the wear facets revealed that surface textures at the edges were rougher than those at the centre of all facets. The results of this study indicated that enamel wear was induced by contact with zirconia brackets during the early period of mastication, and that the patterns and number of cycles of mastication affected the wear progression of enamel.
- 21 October 2021
- Published by Wiley in European Journal of Oral Sciences
- Vol. 130 (1) , e12831
Influence of masticating cycles and chewing patterns on inadvertent enamel wear caused by zirconia brackets
Little information is available about enamel wear caused by zirconia brackets, an inadvertent side effect of orthodontic treatment. The purpose of this study was to examine potential enamel damage induced by contact with zirconia brackets. Sliding and impact wear simulations were performed using bovine enamel specimens positioned at a 25° slant to a zirconium ball to determine wear behaviour. Different chewing patterns, tapping and grinding, were simulated. Specimens were profiled using confocal laser scanning microscopy, and the mean maximum depth and surface roughness were measured. Scanning electron microscopy was also performed. The mean maximum depth of wear values differed according to the number of mastication cycles, with a higher number of cycles producing higher depths of wear. The facet wear depth was significantly greater with the tapping pattern than with the grinding pattern. Scanning electron microscopic observation of the wear facets revealed that surface textures at the edges were rougher than those at the centre of all facets. The results of this study indicated that enamel wear was induced by contact with zirconia brackets during the early period of mastication, and that the patterns and number of cycles of mastication affected the wear progression of enamel.
- Open Access
- 6 September 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (17) , 8251
Influence of Pre-Etched Area and Functional Monomers on the Enamel Bond Strength of Orthodontic Adhesive Pastes
This study was performed to investigate the influence of pre-etching area and functional monomers in orthodontic adhesive pastes on enamel bond strength. Bovine enamel was partially pre-etched with phosphoric acid for 30 s over areas with a diameter of 1.0, 2.0 or 3.0 mm, and metal brackets were then bonded with or without functional monomers in the orthodontic adhesive paste. For the baseline groups, the whole adherent area was pre-etched. The shear bond strength (SBS) and adhesive remnant index (ARI) were determined. The adhesive paste/enamel interfaces were observed by scanning electron microscopy (SEM). Although the adhesive paste with functional monomers showed higher SBS than the functional monomer-free adhesive paste in all groups, there were no significant differences in SBS between them regardless of the pre-etched area. The SBS increased with increasing pre-etched area in both orthodontic adhesive pastes. In SEM images of adhesive paste/enamel interfaces, although adhesive with functional monomers showed excellent adaptation, the functional monomer-free adhesive paste showed gap formation at the interface. These findings suggested that the pre-etching area greatly influenced bond strength, regardless of the presence or absence of the functional monomer in the orthodontic adhesive paste.
- 6 September 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (17) , 8251
Open AccessInfluence of Pre-Etched Area and Functional Monomers on the Enamel Bond Strength of Orthodontic Adhesive Pastes
This study was performed to investigate the influence of pre-etching area and functional monomers in orthodontic adhesive pastes on enamel bond strength. Bovine enamel was partially pre-etched with phosphoric acid for 30 s over areas with a diameter of 1.0, 2.0 or 3.0 mm, and metal brackets were then bonded with or without functional monomers in the orthodontic adhesive paste. For the baseline groups, the whole adherent area was pre-etched. The shear bond strength (SBS) and adhesive remnant index (ARI) were determined. The adhesive paste/enamel interfaces were observed by scanning electron microscopy (SEM). Although the adhesive paste with functional monomers showed higher SBS than the functional monomer-free adhesive paste in all groups, there were no significant differences in SBS between them regardless of the pre-etched area. The SBS increased with increasing pre-etched area in both orthodontic adhesive pastes. In SEM images of adhesive paste/enamel interfaces, although adhesive with functional monomers showed excellent adaptation, the functional monomer-free adhesive paste showed gap formation at the interface. These findings suggested that the pre-etching area greatly influenced bond strength, regardless of the presence or absence of the functional monomer in the orthodontic adhesive paste.